Related papers: The Data Acquisition System for the KOTO Experimen…
Liquid argon time projection chambers (LArTPCs) have been proposed as neutrino detectors that combine both large sizes to maximize the number of neutrino interactions and detailed recording of the interaction. The readout of thousands of…
A drift chamber readout system of the DIRAC experiment at CERN is presented. The system is intended to read out the signals from planar chambers operating in a high current mode. The sense wire signals are digitized in the 16-channel…
We describe a dynamic magneto-optical trap (MOT) suitable for the use with vacuum systems in which optical access is limited to a single window. This technique facilitates the long-standing desire of producing integrated atom chips, many of…
To better understand the capture process by a nanopore, we introduce an efficient Kinetic Monte Carlo (KMC) algorithm that can simulate long times and large system sizes by mapping the dynamic of a point-like particle in a 3D spherically…
Quantization-aware training (QAT) is a representative model compression method to reduce redundancy in weights and activations. However, most existing QAT methods require end-to-end training on the entire dataset, which suffers from long…
On-line data assimilation techniques such as ensemble Kalman filters and particle filters lose accuracy dramatically when presented with an unlikely observation. Such an observation may be caused by an unusually large measurement error or…
By coupling on chip a carbon nanotube to a quantum noise detector, a superconductor-insulator-superconductor junction, via a resonant circuit, we measure the emission noise of a carbon nanotube quantum dot in the Kondo regime. The signature…
We describe the readout electronics for the STAR Time Projection Chamber. The system is made up of 136,608 channels of waveform digitizer, each sampling 512 time samples at 6-12 Mega-samples per second. The noise level is about 1000…
The Reactor Experiment for Neutrino Oscillation (RENO) experiment has been taking data using two identical liquid scintillator detectors of 44.5 tons since August 2011. The experiment has observed the disappearance of reactor neutrinos in…
Large liquid argon Time Projection Chambers have been adopted for the DUNE experiment's far detector, which will be composed of four 17 kton detectors situated 1.5 km underground at the Sanford Underground Research Facility. This represents…
The signal digitization for CROSS, a bolometric experiment for the search of neutrinoless double beta decay at LSC - Canfranc Underground Laboratory, will be based on a custom solution comprised of an analog-to-digital board interfaced to…
A charged-particle veto detector was constructed to study the rare decay $K_{L} \rightarrow \pi^{0} \nu \bar{\nu}$ in the J-PARC K$^{\mathrm{O}}$TO experiment. This detector consists of 3mm-thick plastic scintillator strips and wavelength…
We present the design and first test results of a new FADC-based data acquisition (DAQ) system for the Grande array of the KASCADE-Grande experiment. The original KASCADE experiment at the Forschungszentrum Karlsruhe, Germany, has been…
The LHCb experiment is starting to take data in Run 3 with a new DAQ system, capable of performing complete event reconstruction at the full LHC collision rate. One novel opportunity offered by this system is triggering on long-lived…
VERITAS employs a multi-stage data acquisition chain that extends from the VME readout of custom 500 MS/s flash ADC electronics to the construction of telescope events and ultimately the compilation of information from each telescope into…
PETALO (Positron Emission TOF Apparatus based on Liquid xenOn) exploits the unique characteristics of liquid xenon as a scintillator for use in a PET detector. Here initial simulation studies are detailed which highlight the potential of…
In order to reconstruct gamma-gamma physics events tagged with High Energy Tagger (HET) in the KLOE-2 (K LOng Experiment 2), we need to measure the Time Of Flight (TOF) of the electrons and positrons from the KLOE-2 Interaction Point (IP)…
A fast readout system for the upgrade of the COMPASS RICH detector has been developed and successfully used for data taking in 2006 and 2007. The new readout system for the multi-anode PMTs in the central part of the photon detector of the…
As the development of electronic science and technology, electronic data acquisition (DAQ) system is more and more widely applied to nuclear physics experiments. Workstations are often utilized for data storage, data display, data…
The use of one-bit analog-to-digital converters (ADCs) at a receiver is a power-efficient solution for future wireless systems operating with a large signal bandwidth and/or a massive number of receive radio frequency chains. This solution,…