English
Related papers

Related papers: A z-Vertex Trigger for Belle II

200 papers

The Upgrade II of the LHCb detector, foreseen for 2031, will operate at an instantaneous luminosity of 1.5 x 10$^{34}$ cm$^{-2}$s$^{-1}$, accumulating a sample of more than 300 fb$^{-1}$. To cope with the estimated pile-up of 42 and 200…

Instrumentation and Detectors · Physics 2023-05-12 Evangelos Leonidas Gkougkousis

On-detector digital electronics in High-Energy Physics experiments is increasingly being implemented by means of SRAM-based FPGA, due to their capabilities of reconfiguration, real-time processing and multi-gigabit data transfer.…

Instrumentation and Detectors · Physics 2022-01-05 R. Giordano , Y. Lai , S. Korpar , R. Pestotnik , A. Lozar , L. Santelj , M. Shoji , S. Nishida

The Belle II barrel region is instrumented with the Time of Propagation (TOP) particle identification system based on sixteen fused-silica bars arranged around the interaction point acting as Cherenkov radiator. Due to the mechanical design…

Instrumentation and Detectors · Physics 2022-03-16 Oskar Hartbrich , Umberto Tamponi , Gary S. Varner

The experiments at LHC are implementing novel and challenging detector upgrades for the High Luminosity LHC, among which the tracking systems. This paper reports on performance studies, illustrated by an electron trigger, using a simplified…

High Energy Physics - Experiment · Physics 2024-03-27 Junho Kim , Jongho Lee , Chang-Seong Moon , Aurore Savoy-Navarro , Un-Ki Yang

A new type of ring-imaging Cherenkov counter, called TOP counter, has been developed for particle identification at the Belle II experiment to run at the SuperKEKB accelerator in KEK, Japan. The detector consists of 16 identical modules…

Instrumentation and Detectors · Physics 2019-08-14 Boqun Wang

The Multipurpose Detector (MPD) consists of a typical array of sub-detectors to study the nuclear matter originating from the collisions of beams provided by the Nuclotron-based Ion Collider fAcility (NICA). A beam monitoring…

A new tracking detector will be installed as part of the Phase-2 upgrade of the CMS detector for the high-luminosity LHC era. This tracking detector includes the Inner Tracker, equipped with silicon pixel sensor modules, and the Outer…

Instrumentation and Detectors · Physics 2024-09-02 The Tracker Group of the CMS Collaboration

The Belle II experiment is a high-energy physics experiment at the SuperKEKB electron-positron collider. Using Belle II data, high precision measurement of rare decays and CP-violation in heavy quarks and leptons can be performed to probe…

Instrumentation and Detectors · Physics 2024-10-30 Y. -K. Kim , S. -J. Cho , S. -H. Park , M. Nakao , T. Konno

BTeV is a $B$-physics experiment that expects to begin collecting data at the C0 interaction region of the Fermilab Tevatron in the year 2006. Its primary goal is to achieve unprecedented levels of sensitivity in the study of CP violation,…

High Energy Physics - Experiment · Physics 2019-08-14 Michael H. L. S. Wang

After a highly successful first data taking period at the LHC, the LHCb experiment developed a new trigger strategy with a real-time reconstruction, alignment and calibration for Run II. This strategy relies on offline-like track…

Instrumentation and Detectors · Physics 2017-11-23 Marian Stahl

The CDF-II experiment is a multipurpose detector designed to study a wide range of processes observed in the high energy proton-antiproton collisions produced by the Fermilab Tevatron. With event rates greater than 1MHz, the CDF-II trigger…

The trigger selection capabilities of the ATLAS detector have been significantly enhanced for the LHC Run- 2 in order to cope with the higher event rates and with the large number of simultaneous interactions (pile-up) per protonproton…

High Energy Physics - Experiment · Physics 2020-09-18 Pierre-Hugues Beauchemin

The CMS experiment has been designed with a two-level trigger system: the Level-1 Trigger, implemented on custom-designed electronics, and the High Level Trigger, a streamlined version of the CMS offline reconstruction software running on a…

Instrumentation and Detectors · Physics 2020-11-19 Thiago R. F. P. Tomei

The barrel-region particle identification detector is crucial for extending the physics reach of the Belle II experiment operating at the SuperKEKB accelerator. For this purpose, an imaging-Time-of-Propagation (iTOP) counter was developed,…

Instrumentation and Detectors · Physics 2017-10-10 Boqun Wang

We report on the construction, operation, and performance of the Time-of-Propagation detector with imaging used for the Belle II experiment running at the Super-KEKB $e^+e^-$ collider. This detector is located in the central barrel region…

A significant upgrade of the LHCb detector is scheduled to be installed in 2018-2019. Afterwards all sub-detectors will be read out at the LHC bunch crossing frequency of 40 MHz and the trigger will be fully implemented in software. The…

Instrumentation and Detectors · Physics 2015-05-20 E. Jans

A fast trigger system is being designed as a potential upgrade to VERITAS, or as the basis for a future array of imaging atmospheric-Cherenkov telescopes such as AGIS. The scientific goal is a reduction of the energy threshold by a factor…

Instrumentation and Methods for Astrophysics · Physics 2009-08-04 M. Schroedter , J. Anderson , K. Byrum , G. Drake , C. Duke , J. Holder , A. Imran , A. Madhavan , F. Krennrich , A. Kreps , A. Smith

DEPleted Field Effect Transistor (DEPFET) active pixel detectors combine a first amplification stage with a fully depleted sensor in one single device, resulting in a very good signal-to-noise ratio even for thin sensors. DEPFET pixels are…

Instrumentation and Detectors · Physics 2010-10-19 P. Vazquez

This proceedings describes the XFT stereo upgrade for the CDF Level 2 trigger system. Starting with the stereo finder boards, up to the XFT stereo track algorithim implementation in the Level 2 PC. This proceedings will discuss the…

Instrumentation and Detectors · Physics 2008-08-06 David Cox

T2K is a long baseline neutrino experiment, entering Phase II with a Near Detector upgrade. The T2K near detector (ND280) upgrade consists of the installation of three new detector systems: a plastic scintillator neutrino active target…