English
Related papers

Related papers: Boron-10 layers, Neutron Reflectometry and Thermal…

200 papers

Nowadays neutron scattering science is increasing its instrumental power. Most of the neutron sources in the world are pushing the development of their technologies to be more performing. The neutron scattering development is also pushed by…

Instrumentation and Detectors · Physics 2019-08-14 Francesco Piscitelli

The Multi-Blade is a Boron-10-based gaseous detector introduced to face the challenge arising in neutron reflectometry at pulsed neutron sources. Neutron reflectometers are the most challenging instruments in terms of instantaneous counting…

In the last few years many detector technologies for thermal neutron detection have been developed in order to face the shortage of 3He, which is now much less available and more expensive. Moreover the 3He-based detectors can not fulfil…

Instrumentation and Detectors · Physics 2018-04-12 G. Mauri , F. Messi , K. Kanaki , R. Hall-Wilton , E. Karnickis , A. Khaplanov , F. Piscitelli

Neutron scattering techniques offer a unique combination of structural and the dynamic information of atomic and molecular systems over a wide range of distances and times. The increasing complexity in science investigations driven by…

Instrumentation and Detectors · Physics 2019-05-30 Giacomo Mauri

Although for large area detectors it is crucial to find an alternative to detect thermal neutrons because of the 3He shortage, this is not the case for small area detectors. Neutron scattering science is still growing its instruments' power…

Instrumentation and Detectors · Physics 2014-03-14 F. Piscitelli , J. C. Buffet , J. F. Clergeau , S. Cuccaro , B. Guerard , A. Khaplanov , Q. La Manna , J. M. Rigal , P. Van Esch

The boron-10 based Multi-Grid detector is being developed as an alternative to helium-3 based neutron detectors. At the European Spallation Source, the detector will be used for time-of-flight neutron spectroscopy at cold to thermal neutron…

The Multi-Blade is a Boron-10-based gaseous detector developed for neutron reflectometry instruments at the European Spallation Source (ESS) in Sweden. The main challenges for neutron reflectometry detectors are the instantaneous counting…

Over the last decades, the field of thermal neutron detection has overwhelmingly employed He-3-based technologies. The He-3 crisis together with the forthcoming establishment of the European Spallation Source have necessitated the…

The Multi-Blade is a Boron-10-based gaseous thermal neutron detector developed to face the challenge arising in neutron reflectometry at neutron sources. Neutron reflectometers are challenging instruments in terms of instantaneous counting…

The 3He-based neutron detectors are no longer the default solution for neutron scattering applications. Both the inability of fulfilling the requirements in performance, needed for the new instruments, and the shortage of 3He, drove a…

Instrumentation and Detectors · Physics 2020-03-13 Giacomo Mauri , Francesco Messi , Kalliopi Kanaki , Richard Hall-Wilton , Francesco Piscitelli

The present supply of 3He can no longer meet the detector demands of the upcoming ESS facility and continued detector upgrades at current neutron sources. Therefore viable alternative technologies are required to support the development of…

The Multi-Blade is a Boron-10-based neutron detector designed for neutron reflectometers and developed for the two instruments (Estia and FREIA) planned for the European Spallation Source in Sweden. A reflectometry demonstrator has been…

The European Spallation Source (ESS) in Lund, Sweden will become the world's leading neutron source for the study of materials. The instruments are being selected from conceptual proposals submitted by groups from around Europe. These…

In the field of neutron scattering science, a large variety of instruments require detectors for thermal and cold neutrons. Helium-3 has been one of the main actors in thermal and cold neutron detection for many years. Nowadays neutron…

Instrumentation and Detectors · Physics 2020-07-21 Francesco Piscitelli , Giacomo Mauri , Alessio Laloni , Richard Hall-Wilton

The $^3$He(n,p) process is excellent for neutron detection between thermal and $\sim$4\,MeV because of the high cross section and near-complete energy transfer from the neutron to the proton. Traditional gaseous $^3$He detectors using this…

Instrumentation and Detectors · Physics 2024-09-04 A. N. Villano

The ambitious instrument suite for the future European Spallation Source whose civil construction started recently in Lund, Sweden, demands a set of diverse and challenging requirements for the neutron detectors. For instance, the…

The worldwide need to replace 3He for the neutron detection has triggered R&D on new technologies and methods. A promising one is based on commercial solid state silicon detectors coupled with thin neutron converter layers containing 6Li.…

Instrumentation and Detectors · Physics 2016-01-20 A. Pappalardo , M. Barbagallo , L. Cosentino , C. Marchetta , A. Musumarra , C. Scirè , S. Scirè , G. Vecchio , P. Finocchiaro

The globally increased demand for helium-3 along with the limited availability of this gas calls for the development of alternative technologies for the large ESS instrumentation pool. We report on the CASCADE Project - a novel detection…

Instrumentation and Detectors · Physics 2016-11-03 M. Köhli , M. Klein , F. Allmendinger , A. -K. Perrevoort , T. Schröder , N. Martin , C. J. Schmidt , U. Schmidt

The European Spallation Source (ESS) is the world's next generation spallation-based neutron source. The research conducted at ESS will yield in the discovery and development of new materials including the fields of manufacturing,…

Instrumentation and Detectors · Physics 2019-02-20 Gabor Galgoczi , Kalliopi Kanaki , Francesco Piscitelli , Thomas Kittelmann , Dezso Varga , Richard Hall-Wilton

Currently, many detector technologies for thermal neutron detection are in development in order to lower the demand for the rare 3He gas. Gas detectors with solid thin film neutron converters readout by gas proportional counter method have…

‹ Prev 1 2 3 10 Next ›