English
Related papers

Related papers: Multigap RPC time resolution to 511 keV annihilati…

200 papers

A new Time Projection Chamber (TPC) is currently under development for the sPHENIX experiment at RHIC. The TPC will be read out using multistage GEM detectors on each end and will be divided into approximately 40 pad layers in radius. Each…

Instrumentation and Detectors · Physics 2018-08-15 B. Azmoun , P. Garg , T. K. Hemmick , M. Hohlmann , A. Kiselev , M. L. Purschke , C. Woody , A. Zhang

Multi-Pixel Photon Counter (MPPC) has been recently emerged and realized as a great type of Silicon Photomultiplier to replace or compensate for the conventional vacuum-based Photomultiplier tubes. MPPC provides many striking features such…

Instrumentation and Detectors · Physics 2021-06-17 N. H. Duy Thanh , N. V. Chi Lan , C. V. Son , T. V. Ngoc , P. T. Quyen , N. Khoa , N. T. Hong Van

Spatial resolution of less than 200 um is challenging for thermal neutron detection. A novel readout scheme based on the time-projection-chamber (TPC) concept is used in a gaseous electron multiplier (GEM) detector. Thermal neutrons are…

Instrumentation and Detectors · Physics 2016-06-22 Bernhard Flierl , Otmar Biebel , Ralf Hertenberger , Karl Zeitelhack

The 50~kton Iron Calorimeter (ICAL) detector at the underground India based Neutrino Observatory (INO) will make measurements on atmospheric neutrinos. Muons produced in charged current (CC) interactions of muon neutrinos with the iron are…

Instrumentation and Detectors · Physics 2014-10-22 N. Dash , V. M. Datar , G. Majumder

The NEXT-White detector, a high-pressure gaseous xenon time projection chamber, demonstrated the excellence of this technology for future neutrinoless double beta decay searches using photomultiplier tubes (PMTs) to measure energy and…

High Energy Physics - Experiment · Physics 2024-08-19 T. Contreras , B. Palmeiro , H. Almazán , A. Para , G. Martínez-Lema , R. Guenette , C. Adams , V. Álvarez , B. Aparicio , A. I. Aranburu , L. Arazi , I. J. Arnquist , F. Auria-Luna , S. Ayet , C. D. R. Azevedo , K. Bailey , F. Ballester , M. del Barrio-Torregrosa , A. Bayo , J. M. Benlloch-Rodríguez , F. I. G. M. Borges , A. Brodolin , N. Byrnes , S. Cárcel , A. Castillo , S. Cebrián , E. Church , L. Cid , C. A. N. Conde , F. P. Cossío , E. Dey , G. Díaz , T. Dickel , C. Echevarria , M. Elorza , J. Escada , R. Esteve , R. Felkai , L. M. P. Fernandes , P. Ferrario , A. L. Ferreira , F. W. Foss , Z. Freixa , J. García-Barrena , J. J. Gómez-Cadenas , R. González , J. W. R. Grocott , J. Hauptman , C. A. O. Henriques , J. A. Hernando Morata , P. Herrero-Gómez , V. Herrero , C. Hervés Carrete , Y. Ifergan , B. J. P. Jones , F. Kellerer , L. Larizgoitia , A. Larumbe , P. Lebrun , F. Lopez , N. López-March , R. Madigan , R. D. P. Mano , A. P. Marques , J. Martín-Albo , M. Martínez-Vara , R. L. Miller , K. Mistry , J. Molina-Canteras , F. Monrabal , C. M. B. Monteiro , F. J. Mora , K. E. Navarro , P. Novella , A. Nuñez , D. R. Nygren , E. Oblak , J. Palacio , I. Parmaksiz , A. Pazos , J. Pelegrin , M. Pérez Maneiro , M. Querol , A. B. Redwine , J. Renner , I. Rivilla , C. Rogero , L. Rogers , B. Romeo , C. Romo-Luque , F. P. Santos , J. M. F. dos Santos , M. Seemann , I. Shomroni , P. A. O. C. Silva , A. Simón , S. R. Soleti , M. Sorel , J. Soto-Oton , J. M. R. Teixeira , S. Teruel-Pardo , J. F. Toledo , C. Tonnelé , J. Torrent , A. Trettin , A. Usón , P. R. G. Valle , J. F. C. A. Veloso , J. Waiton , A. Yubero-Navarro

We present here detailed derivations of mathematical expressions for the accuracy in the arrival direction of particles estimated using a set of stacked resistive plate chambers (RPCs). The expressions are validated against experimental…

Instrumentation and Detectors · Physics 2017-02-08 Deepak Samuel , Pratibha B Onikeri , Lakshmi P Murgod

We consider evidence integration from potentially dependent observation processes under varying spatio-temporal sampling resolutions and noise levels. We develop a multi-resolution multi-task (MRGP) framework while allowing for both…

Machine Learning · Statistics 2019-11-06 Oliver Hamelijnck , Theodoros Damoulas , Kangrui Wang , Mark Girolami

The potential of photon detectors to achieve precise timing information is of increasing importance in many domains, PET and CT scanners in medical imaging and particle physics detectors, amongst others. The goal to increase by an order of…

Instrumentation and Detectors · Physics 2021-01-11 S. Enoch , A. Gola , P. Lecoq , A. Rivetti

We report on the development of a large-volume, wide field-of-view time projection chamber (TPC) for X-ray polarimetry, featuring a triple-GEM amplification stage and optical readout. Originally developed within the CYGNO program for…

We have investigated the effects caused by proton-induced radiation damage on Multi-Pixel Photon Counter (MPPC), a pixelized photon detector developed by Hamamatsu Photonics. The leakage current of irradiated MPPC samples linearly increases…

Instrumentation and Detectors · Physics 2014-10-01 T. Matsumura , T. Matsubara , T. Hiraiwa , K. Horie , M. Kuze , K. Miyabayashi , A. Okamura , T. Sawada , S. Shimizu , T. Shinkawa , T. Tsunemi , M. Yosoi

The construction of a butt-end multicell matrix proportional counter (MMPC) is presented in the work. Each cell is a butt-end proportional counter with a 5 mm cathode diameter and 0.8 mm circular anode diameter. In the example of the…

We have tested a prototype time-of-flight system based on bulk scintillator block of dimensions $2.5 \times 2.5 \times 200$ cm. Using a calibration scheme similar to the one used in actual collider experiments, we have achieved a resolution…

High Energy Physics - Experiment · Physics 2007-05-23 E. Chen , M. Saulnier , W. Sun , H. Yamamoto

This work explores the combination of liquid xenon as a scintillating medium and silicon photomultipliers as a readout in Positron Emission Tomography (PET) for enhanced Time-Of-Flight resolution. We present the results of our first…

The Compressed Baryonic Matter spectrometer (CBM) is a future fixed-target heavy-ion experiment located at the Facility for Anti-proton and Ion Research (FAIR) in Darmstadt, Germany. The key element in CBM providing hadron identification at…

Instrumentation and Detectors · Physics 2020-01-29 I. Deppner , N. Herrmann

Current {\gamma}-ray telescopes based on photon conversions to electron-positron pairs, such as Fermi, use tungsten converters. They suffer of limited angular resolution at low energies, and their sensitivity drops below 1 GeV. The low…

In the last years, high-resolution time tagging has emerged as the tool to tackle the problem of high-track density in the detectors of the next generation of experiments at particle colliders. Time resolutions below 50ps and event average…

Spherical time projection chambers (TPC), also known as spherical proportional counters, are employed in the search for rare phenomena, such as light Dark Matter candidates. The spherical TPC exhibits a number of essential features, making…

The prototype of a TDC board has been developed for the new high granular time-of-flight neutron detector (HGND). The board is based on the standard LVDS 4x asynchronous oversampling using the xc7k160 FPGA with a 100 ps bin width. The HGND…

Instrumentation and Detectors · Physics 2024-01-23 D. Finogeev , F. Guber , A. Izvestnyy , N. Karpushkin , A. Makhnev , S. Morozov , D. Serebryakov

We have developed a Multi-Pixel Photon Counter (MPPC) for the neutrino detectors of T2K experiment. About 64,000 MPPCs have been produced and tested in about a year. In order to characterize a large number of MPPCs, we have developed a…

Instrumentation and Detectors · Physics 2014-11-21 M. Yokoyama , A. Minamino , S. Gomi , K. Ieki , N. Nagai , T. Nakaya , K. Nitta , D. Orme , M. Otani , T. Murakami , T. Nakadaira , M. Tanaka