English
Related papers

Related papers: Measurements and optimization of the light yield o…

200 papers

Bolometers have proven to be good instruments to search for rare processes because of their excellent energy resolution and their extremely low intrinsic background. In this kind of detectors, the capability of discriminating alpha…

Instrumentation and Detectors · Physics 2015-06-11 F. Bellini , N. Casali , I. Dafinei , M. Marafini , S. Morganti , F. Orio , D. Pinci , M. Vignati , C. Voena

TeO$_2$ crystals have proven to be superb bolometers for the search of neutrinoless double beta decay in many respects. However, if used alone, they do not exhibit any feature that allows to discriminate an alpha energy deposit from a…

Instrumentation and Detectors · Physics 2012-02-13 J. W. Beeman , F. Bellini , L. Cardani , N. Casali , I. Dafinei , S. Di Domizio , F. Ferroni , F. Orio , G. Pessina , S. Pirro , C. Tomei , M. Vignati

The most sensitive process able to probe the Majorana nature of neutrinos and discover Lepton Number Violation is the neutrino-less double beta decay. Thanks to the excellent energy resolution, efficiency and intrinsic radio-purity,…

Instrumentation and Detectors · Physics 2017-05-03 Nicola Casali

The anticipated use of more than one thousand lead fluoride (PbF2) crystals as a fast and compact Cherenkov calorimeter material in a parity violation experiment at MAMI stimulated the investigation of the light yield (L.Y.) of these…

Nuclear Experiment · Physics 2009-02-23 P. Achenbach , S. Baunack , K. Grimm , T. Hammel , D. von Harrach , A. Lopes Ginja , F. E. Maas , E. Schilling , H. Stroeher

A new generation of cryogenic light detectors exploiting Neganov-Luke effect to enhance the thermal signal has been used to detect the Cherenkov light emitted by the electrons interacting in TeO$_{2}$ crystals. With this mechanism a high…

Simultaneous measurement of phonon and light signatures is an effective way to reduce the backgrounds and increase the sensitivity of CUPID, a next-generation bolometric neutrinoless double-beta decay ($0\nu\beta\beta$) experiment. Light…

Instrumentation and Detectors · Physics 2019-10-31 R. G. Huang , G. Benato , J. Caravaca , Yu. G. Kolomensky , B. J. Land , G. D. Orebi Gann , B. Schmidt

Future lepton colliders such as the FCC-ee, CEPC, ILC, or a muon collider will collect large data samples that allow precision physics studies with unprecedented accuracy, especially when the data is collected by innovative state-of-the-art…

Bolometers have proven to be good detectors for the search of neutrinoless double beta decay. By operating at cryogenic temperatures, they feature excellent energy resolution and low background. The detection of the possible light emitted…

Data Analysis, Statistics and Probability · Physics 2011-10-10 G. Piperno , S. Pirro , M. Vignati

A hybrid dual-readout calorimeter concept, comprising both electromagnetic and hadronic sections, has recently been proposed to meet the performance requirements of experiments at future e$^{+}$e$^{-}$ colliders. The front compartment…

Instrumentation and Detectors · Physics 2026-03-20 Andrea Benaglia , Flavia Cetorelli , Marco Toliman Lucchini , Etiennette Auffray , Louis Roux , Julie Delenne

We study the possibility to use the Cherenkov light for the efficient detection of 511 keV photons with the goal to use it in TOF-PET. We designed and tested two detection modules consisting of PbF$_2$ crystals attached to Planacon MCP-PMT…

Instrumentation and Detectors · Physics 2020-03-24 C. Canot , M. Alokhina , P. Abbon , J. P. Bard , D. Breton , E. Delagnes , J. Maalmi , G. Tauzin , D. Yvon , V. Sharyy

We have developed and tested a new way of coupling bolometric light detectors to scintillating crystal bolometers based upon simply resting the light detector on the crystal surface, held in position only by gravity. This straightforward…

Instrumentation and Detectors · Physics 2019-05-30 M. Barucci , J. W. Beeman , V. Caracciolo , L. Pagnanini , L. Pattavina , G. Pessina , S. Pirro , C. Rusconi , K. Schäffner

Results are presented of detailed measurements of the signals generated by high-energy electrons and muons in lead tungstate crystals. A significant fraction of the light produced in these crystals and detected by photomultiplier tubes is…

Instrumentation and Detectors · Physics 2009-11-13 N. Akchurin

A Cherenkov detector based on an array of five lead fluoride ($\beta$-PbF$_2$) crystals of size 30 mm$\times$30 mm$\times$160 mm read out by reverse-type avalanche photodiodes (APD's) of active area 10 mm$\times$10 mm was used to measure…

Instrumentation and Detectors · Physics 2019-11-07 Y. Murakami , H. Aghai-Khozani , M. Hori

We present results of horizontal EAS simulations focused on the opportunity of measuring Cherenkov light from air showers at stratospheric balloon altitude (eg. EUSO-SPB2). For a 1 m2 UV light detector at a 38 km altitude, the largest…

Instrumentation and Methods for Astrophysics · Physics 2019-09-30 K. Królik , A. Djakonow , Z. Plebaniak , M. Przybylak , J. Szabelski , L. Wiencke

Cosmic ray detectors use air as a radiator for luminescence. In water and ice, Cherenkov light is the dominant light producing mechanism when the particle's velocity exceeds the Cherenkov threshold, approximately three quarters of the speed…

Instrumentation and Methods for Astrophysics · Physics 2016-10-21 Anna Obertacke Pollmann

We describe the particle identification capability of the CLEO RICH system. This system consists of a 1 cm thick LiF radiator coupled to a photon detector that uses wire proportional chambers filled with a mixture of CH$_4$ and TEA. We…

Instrumentation and Detectors · Physics 2019-08-14 R. Sia

Halide perovskite semiconductors such as CsPbBr3 (CLB) are emerging gamma-ray detectors for applications requiring very high energy resolution and potential for fine detector segmentation. Semiconductor detectors typically offer poor time…

We describe the design, construction and performance of a Ring Imaging Cherenkov Detector (RICH) constructed to identify charged particles in the CLEO experiment. Cherenkov radiation occurs in LiF crystals, both planar and ones with a novel…

We report on the construction, operation, and performance of the Time-of-Propagation detector with imaging used for the Belle II experiment running at the Super-KEKB $e^+e^-$ collider. This detector is located in the central barrel region…

Using aerogel as radiator and multianode PMTs for photon detection, a proximity focusing Cherenkov ring imaging detector has been constructed and tested in the KEK $\pi$2 beam. The aim is to experimentally study the basic parameters such as…

High Energy Physics - Experiment · Physics 2009-01-09 I. Adachi , I. Bizjak , A. Gorisek , T. Iijima , M. Iwamoto , S. Korpar , P. Krizan , R. Pestotnik , M. Staric , A. Stanovnik , T. Sumiyoshi , K. Suzuki , T. Tabata
‹ Prev 1 2 3 10 Next ›