In X-ray CT scan with metallic objects, it is known that direct application of the filtered back-projection (FBP) formula leads to streaking artifacts in the reconstruction. These are characterized mathematically in terms of wave front sets…
In computed tomography (CT), metal implants increase the inconsistencies between the measured data and the linear attenuation assumption made by analytic CT reconstruction algorithms. The inconsistencies give rise to dark and bright bands…
We study artifacts in the reconstruction of X-ray tomography due to nonlinear effects. For non-convex metal objects, we analyze the new phenomena of streak artifacts from inflection points on the boundary of metal objects. We characterize…
During X-ray computed tomography (CT) scanning, metallic implants carrying with patients often lead to adverse artifacts in the captured CT images and then impair the clinical treatment. Against this metal artifact reduction (MAR) task, the…
Metal objects pose a significant challenge in cone-beam computed tomography, as their strong and energy-dependent X-ray attenuation leads to inconsistent projections and severe streaking and shading artifacts in reconstructed images. These…
X-ray computed tomography (CT) is widely utilized in the medical, industrial, and other fields to nondestructively generate three-dimensional structural images of objects. However, CT images are often affected by various artifacts, with…
Computed tomography (CT) is an imaging modality widely used for medical diagnosis and treatment. CT images are often corrupted by undesirable artifacts when metallic implants are carried by patients, which creates the problem of metal…
Metal artifact reduction (MAR) in computed tomography (CT) is a notoriously challenging task because the artifacts are structured and non-local in the image domain. However, they are inherently local in the sinogram domain. Thus, one…
Metallic implants introduce severe artifacts in CT images, which degrades the image quality. It is an effective method to reduce metal artifacts by replacing the metal affected projection with the forward projection of a prior image. How to…
Computed tomography (CT) images containing metallic objects commonly show severe streaking and shadow artifacts. Metal artifacts are caused by nonlinear beam-hardening effects combined with other factors such as scatter and Poisson noise.…
The mathematical foundation of X-ray CT is based on the assumption that by measuring the attenuation of X-rays passing through an object, one can recover the integrals of the attenuation coefficient $\mu(x)$ along a sufficiently rich family…
Ring artifacts are common artifacts in CT imaging, typically caused by inconsistent responses of detector units to X-rays, resulting in stripe artifacts in the projection data. Under circular scanning mode, such artifacts manifest as…
Ring artifacts in X-ray micro-CT images are one of the primary causes of concern in their accurate visual interpretation and quantitative analysis. The geometry of X-ray micro-CT scanners is similar to the medical CT machines, except the…
We study streaking artifacts caused by beam-hardening effects in X-ray computed tomography (CT). The effect is known to be nonlinear. We show that the nonlinearity can be recovered from the observed artifacts for strictly convex bodies. The…
Metal artifacts is a major challenge in computed tomography (CT) imaging, significantly degrading image quality and making accurate diagnosis difficult. However, previous methods either require prior knowledge of the location of metal…
Low-dose dental cone beam computed tomography (CBCT) has been increasingly used for maxillofacial modeling. However, the presence of metallic inserts, such as implants, crowns, and dental filling, causes severe streaking and shading…
This article provides a mathematical analysis of singular (nonsmooth) artifacts added to reconstructions by filtered backprojection (FBP) type algorithms for X-ray CT with arbitrary incomplete data. We prove that these singular artifacts…
The presence of metallic implants often introduces severe metal artifacts in the X-ray CT images, which could adversely influence clinical diagnosis or dose calculation in radiation therapy. In this work, we present a novel…
Metal artifacts in computed tomography (CT) arise from a mismatch between physics of image formation and idealized assumptions during tomographic reconstruction. These artifacts are particularly strong around metal implants, inhibiting…
Metal artifact correction is a challenging problem in cone beam computed tomography (CBCT) scanning. Metal implants inserted into the anatomy cause severe artifacts in reconstructed images. Widely used inpainting-based metal artifact…