Related papers: Visible-light beam size monitors using synchrotron…
The uncertainty of the energy measurement of the electron beam on circular electron positron collider (CEPC) must be smaller than 10$\mathrm{MeV}$ to make sure the accurate measurement of the mass of the Higgs boson. In order to simplify…
This paper introduces the Infra-Red, In Situ (IRIS) inspection method, which uses short-wave IR (SWIR) light to non-destructively "see through" the backside of chips and image them with lightly modified conventional digital CMOS cameras.…
A large-area and light-weight Gas Electron Multiplier (GEM) detector was built at the University of Virginia as a prototype for the detector R$\&$D program of the future Electron Ion Collider. The prototype has a trapezoidal geometry…
Visual inspection of solar modules is an important monitoring facility in photovoltaic power plants. Since a single measurement of fast CMOS sensors is limited in spatial resolution and often not sufficient to reliably detect small defects,…
A superconducting radio-frequency (SRF) photo injector is in operation at the electron linac for beams with high brilliance and low emittance (ELBE) radiation center and generates continuous wave (CW) electron beams with high average…
Young's double slit experiment has been the most explored technique to gauge the coherence properties of a given system. The limits of this technique in characterizing spatial coherence properties of high emittance, hard x-ray synchrotron…
Generally, turn-to-turn power fluctuations of incoherent spontaneous synchrotron radiation in a storage ring depend on the 6D phase-space distribution of the electron bunch. In some cases, if only one parameter of the distribution is…
Various phase shifters and absorbers can be put into the arms of a double loop neutron interferometer. The mean intensity levels of the forward and diffracted beams behind an empty four plate interferometer of this type have been…
Conventional silicon photomultipliers (SiPMs) are well established as light detectors with single-photon-detection capability and used throughout high energy physics, medical, and commercial applications. The possibility to produce single…
We present a method to measure transverse size and position of an electron or proton beam, close to the injection point in plasma wakefields, where other diagnostics are not available. We show that transverse size measurements are in…
The CMS silicon tracker, consisting of 1440 silicon pixel and 15148 silicon strip detector modules, has been aligned using more than three million cosmic ray charged particles, with additional information from optical surveys. The positions…
We present 36 observations of 17 visual binaries of moderate separation (range from 0.15'' to 0.79'') made with the 50 cm Cassegrain telescope of the Jagiellonian University in Cracow. The speckle interferometry technique was combined with…
We implement a time-of-flight imaging technique utilizing a differential-readout SNSPD to spatially resolve detection events in a fiber-coupled detector platform. We measure the spatial detection profiles for ultra-high numerical aperture…
Beam tests using tracking telescopes are a standard method for determining the spatial resolution of detectors. This requires the precise knowledge of the position resolution of beam tracks reconstructed at the Device Under Test (DUT). A…
Coherent Synchrotron Radiation (CSR) can play an important role by not only increasing the energy spread and emittance of a beam, but also leading to a potential instability. Previous studies of the CSR induced longitudinal instability were…
The Visible-light Imager and Magnetograph (VIM) proposed for the ESA Solar Orbiter mission will observe a photospheric spectral line at high spatial resolution. Here we simulate and interpret VIM measurements. Realistic MHD models are used…
Plastic scintillator detectors have been extensively used in particle physics experiments for decades. A large-scale detector is typically arranged as an array of staggered long bars which provide a fast trigger signal and/or particle…
We present the results of an experiment where a short focal length (~ 1.3 cm) permanent magnet electron lens is used to image micron-size features of a metal sample in a single shot, using an ultra- high brightness ps-long 4 MeV electron…
Scanning electron microscopy (SEM) is indispensable in diverse applications ranging from microelectronics to food processing because it provides large depth-of-field images with a resolution beyond the optical diffraction limit. However,…
The Single electron Sensitive Read Out (SiSeRO) is a novel on-chip charge detector output stage for charge-coupled device (CCD) image sensors. Developed at MIT Lincoln Laboratory, this technology uses a p-MOSFET transistor with a depleted…