Related papers: Visible-light beam size monitors using synchrotron…
A liquid isooctane (C$_{8}$H$_{18}$) filled ionization linear array for radiotherapy quality assurance has been designed, built and tested. The detector consists of 128 pixels, each of them with an area of 1.7 mm $\times$ 1.7 mm and a gap…
The Atomic Spectroscopy and Collisions Using Slow Antiprotons (ASACUSA) experiment at the Antiproton Decelerator (AD) facility of CERN constructed segmented scintillators to detect and track the charged pions which emerge from antiproton…
In order to facilitate IR absorption measurements of mass-selected ions isolated in cryogenic matrices, we have upgraded an ion beam deposition apparatus encompassing a Bruker IFS66v/S FTIR spectrometer. A synthetic diamond beam splitter…
A series of beam tests were conducted at the KEK AR test beamline in ordet to investigate the performance of a prototype detector for instrumentation in the low-E beamline at the CERN H2 line. For the silicon strip detector, the…
The Optically Segmented Single Volume Scatter Camera (OS-SVSC) aims to image neutron sources for non-proliferation applications using the kinematic reconstruction of elastic double-scatter events. Our prototype system consists of 64 EJ-204…
The polarimetric self-coherent system using a direct-detection-based Stokes-vector receiver (SVR) is a promising technology to meet both the cost and capacity requirements of the short-reach optical interconnects. However, conventional SVRs…
The cosmic-ray-veto detector (CRV) for the Mu2e experiment consists of four layers of plastic scintillating counters read out by silicon photo-multipliers (SiPM) through wavelength-shifting fibers. This paper reports the light properties of…
Particle therapy is a well established clinical treatment of tumors. More than one hundred particle therapy centers are in operation world wide. The advantage of using hadrons like protons or carbon ions as particles for tumor irradiation…
Using the pre-bunched electron beam of 5-MeV linear accelerator the coherent Smith-Purcell radiation (CSPR) from a flat periodic target (made of conductive layers separated by dielectric gaps) in millimeter wavelength region has been…
A high precision beam monitor system based on silicon carbide PIN sensor is designed for China Spallation Neutron Source 1.6 GeV proton beam to monitor the proton beam fluence.The concept design of the beam monitor system is finished…
The performance of a scintillating fiber (2mm diameter) position sensitive detector ($4.8 \times 4.8$ cm$^2$ active area) for the single bremstrahlung luminosity monitor at the VEPP-2M electron-positron collider in Novosibirsk, Russia is…
At SwissFEL, a fully non-invasive characterization of the beam energy distribution can be performed by means of a Synchrotron-Radiation-Monitor (SRM) imaging in the visible the transverse profile of the electron beam in a magnetic chicane.…
The MIT X-ray Polarimetry Beamline is a facility that we developed for testing components for possible use in X-ray polarimetry. Over the past few years, we have demonstrated that the X-ray source can generate nearly 100% polarized X-rays…
The EDDA-Detector at the Cooler-Synchrotron COSY/J\"ulich has been operated with an internal CH$_2$ fiber target to measure proton-proton elastic scattering differential cross sections. For the data analysis knowledge of beam parameters,…
The CHIRON optical high-resolution echelle spectrometer was commissioned at the 1.5m telescope at CTIO in 2011. The instrument was designed for high throughput and stability, with the goal of monitoring radial velocities of bright stars…
Large imaging arrays of detectors at millimeter and submillimeter wavelengths have applications that include measurements of the faint polarization signal in the Cosmic Microwave Background (CMB), and submillimeter astrophysics. We are…
The performance of scintillator counters with embedded wavelength-shifting fibers has been measured in the Fermilab Meson Test Beam Facility using 120 GeV protons. The counters were extruded with a titanium dioxide surface coating and two…
High-granularity homogeneous electromagnetic calorimeters based on scintillating crystals and silicon photomultipliers (SiPMs) are a promising option for future $e^{+}e^{-}$ Higgs factories, where both excellent energy resolution and a very…
The high-luminosity upgrade of the CERN LHC requires the replacement of the CMS tracking detector to cope with the increased radiation fluence while maintaining its excellent performance. An extensive R\&D program, aiming at using 3D pixel…
The goal of the COMPASS experiment at CERN is to study the structure and dynamics of hadrons. The two-stage spectrometer used by the experiment has large acceptance and covers a wide kinematic range for charged as well as neutral particles…