English
Related papers

Related papers: Phonon-Based Position Determination in SuperCDMS i…

200 papers

Now that conventional weakly interacting massive particle (WIMP) dark matter searches are approaching the neutrino floor, there has been a resurgence of interest in detectors with sensitivity to nuclear recoil directions. A large-scale…

We report the result of a blinded search for Weakly Interacting Massive Particles (WIMPs) using the majority of the SuperCDMS Soudan dataset. With an exposure of 1690 kg days, a single candidate event is observed, consistent with expected…

Four categories of events have been identified in the EDELWEISS-I dark matter experiment using germanium cryogenic detectors measuring simultaneously charge and heat signals. These categories of events are interpreted as electron and…

We consider the absorption by bound electrons of dark matter in the form of dark photons and axion-like particles, as well as of dark photons from the Sun, in current and next-generation direct detection experiments. Experiments sensitive…

High Energy Physics - Phenomenology · Physics 2017-09-22 Itay M. Bloch , Rouven Essig , Kohsaku Tobioka , Tomer Volansky , Tien-Tien Yu

The EDELWEISS-II collaboration has performed a direct search for WIMP dark matter with an array of ten 400 g heat-and-ionization cryogenic detectors equipped with interleaved electrodes for the rejection of near-surface events. Six months…

We report results of a search for Weakly Interacting Massive Particles (WIMPS) with the silicon detectors of the CDMS II experiment. This blind analysis of 140.2 kg-days of data taken between July 2007 and September 2008 revealed three…

The Cryogenic Dark Matter Search experiment (CDMS) employs low-temperature Ge and Si detectors to detect WIMPs via their elastic scattering interaction with the target nuclei. The current analysis of 397.8 kg-days Ge exposure resulted in…

Astrophysics · Physics 2019-08-13 T. Bruch

Presently the CDMS-II collaboration's Weakly Interacting Massive Particle (WIMP) search at the Soudan Underground Laboratory sets the most stringent exclusion limits of any WIMP cold dark matter direct-detection experiment. To extend our…

Microcalorimeters that leverage microwave kinetic inductance detectors to read out phonon signals in the particle-absorbing target, referred to as kinetic inductance phonon-mediated (KIPM) detectors, offer an attractive detector…

Nuclear recoil measurements with high-purity Germanium detectors are very promising to directly detect dark matter candidates. The main background sources in such experiments are natural radioactivity and microphonic noise. Digital pulse…

High Energy Physics - Experiment · Physics 2009-10-31 L. Baudis , J. Hellmig , H. V. Klapdor-Kleingrothaus , Y. Ramachers , J. W. Hammer , A. Mayer

Sodium iodide (NaI) based cryogenic scintillating calorimeters using quantum sensors for signal read out have shown promising first results towards a model-independent test of the annually modulating signal detected by the DAMA/LIBRA dark…

We have developed a contact-less technique for the real time measurement of a-thermal (Cooper-pair breaking) phonons in an absorber held at sub-Kelvin temperatures. In particular, a thin-film aluminum superconducting resonator was realized…

CDMS II data from the 5-tower runs at the Soudan Underground Laboratory were reprocessed with an improved charge-pulse fitting algorithm. Two new analysis techniques to reject surface-event backgrounds were applied to the 612 kg days…

SuperCDMS SNOLAB uses kilogram-scale germanium and silicon detectors to search for dark matter. Each detector has Transition Edge Sensors (TESs) patterned on the top and bottom faces of a large crystal substrate, with the TESs electrically…

Instrumentation and Detectors · Physics 2025-08-28 M. F. Albakry , I. Alkhatib , D. Alonso-Gonzalez , J. Anczarski , T. Aralis , T. Aramaki , I. Ataee Langroudy , C. Bathurst , R. Bhattacharyya , A. J. Biff , P. L. Brink , M. Buchanan , R. Bunker , B. Cabrera , R. Calkins , R. A. Cameron , C. Cartaro , D. G. Cerdeno , Y. -Y. Chang , M. Chaudhuri , J. H. Chen , R. Chen , N. Chott , J. Cooley , H. Coombes , P. Cushman , R. Cyna , S. Das , S. Dharani , M. L. di Vacri , M. D. Diamond , M. Elwan , S. Fallows , E. Fascione , E. Figueroa-Feliciano , S. L. Franzen , A. Gevorgian , M. Ghaith , G. Godden , J. Golatkara , S. R. Golwala , R. Gualtieri , J. Hall , S. A. S. Harms , C. Hays , B. A. Hines , Z. Hong , L. Hsu , M. E. Huber , V. Iyer , V. K. S. Kashyap , S. T. D. Keller , M. H. Kelsey , K. T. Kennard , Z. Kromer , A. Kubik , N. A. Kurinsky , M. Lee , J. Leyva , B. Lichtenberga , J. Liu , Y. Liu , E. Lopez Asamard , P. Lukens , R. Lopez Noe , D. B. MacFarlane , R. Mahapatra , J. S. Mammo , A. J. Mayer , P. C. McNamara , E. Michaud , E. Michielin , K. Mickelson , N. Mirabolfathi , M. Mirzakhani , B. Mohanty , D. Mondal , D. Monteiro , J. Nelson , H. Neog , J. L. Orrell , M. D. Osborne , S. M. Oser , L. Pandey , S. Pandey , R. Partridge , P. K. Patel , D. S. Pedrerosa , W. Peng , W. L. Perry , R. Podviianiuk , M. Potts , S. S. Poudel , A. Pradeep , M. Pyle , W. Rau , T. Reynold , M. Rios , A. Roberts , A. E. Robinson , L. Rosado , J. L. Ryan , T. Saab , D. Sadek , B. Sadoulet , S. P. Sahoo , I. Saikia , S. Salehi , J. Sander , B. Sandoval , A. Sattari , R. W. Schnee , B. Serfass , A. E. Sharbaugh , R. S. Shenoy , A. Simchony , P. Sinervo , Z. J. Smith , R. Soni , K. Stifter , J. Street , M. Stukel , H. Sun , E. Tanner , N. Tenpas , D. Toback , A. N. Villano , J. Viola , B. von Krosigk , O. Wen , Z. William , M. J. Wilson , J. Winchell , S. Yellin , B. A. Young , B. Zatschler , S. Zatschler , A. Zaytsev , E. Zhang , L. Zheng , A. Zuniga , M. J. Zurowski

We discuss the operation principle of a detector based on superheated droplets of Freon-12 and its feasibility for the search of weakly interacting cold dark matter particles. In particular we are interested in a neutralino search…

High Energy Physics - Experiment · Physics 2009-10-28 L. A. Hamel , L. Lessard , L. Rainville , B. Sur , V. Zacek

We present the design and characterization of a large-area Cryogenic PhotoDetector (CPD) designed for active particle identification in rare event searches, such as neutrinoless double beta decay and dark matter experiments. The detector…

A 3-D position sensitive neutron detector is being developed based on a plastic scintillator array. A double side SiPM readout is used to determine the depth of interaction (DOI) in each scintillator unit. In the preliminary test, the DOI…

Instrumentation and Detectors · Physics 2019-07-11 Yang Tian , Yidong Fu , Yulan Li , Yuanjing Li

Cryogenic semiconductor detectors operated at temperatures below 100 mK are commonly used in particle physics experiments searching for dark matter. The largest such germanium and silicon detectors, with diameters of 100 mm and thickness of…

Instrumentation and Detectors · Physics 2018-08-22 N. Mast , A. Kennedy , H. Chagani , D. Codoluto , M. Fritts , R. Harris , A. Jastram , R. Mahapatra , V. Mandic , N. Mirabolfathi , M. Platt , D. Strandberg

A good particle candidate for Cold Dark Matter (CDM) is the supersymmetric neutralino or more generally a weakly interacting massive particle (WIMP). The expected interaction rate of WIMPs with the detector medium in the direct detection…

Instrumentation and Methods for Astrophysics · Physics 2010-02-17 V. Kozlov

We report the first demonstration of a phonon-mediated silicon detector technology that provides a primary phonon measurement in a low-voltage region, and a simultaneous indirect measurement of the ionization signal through…

Instrumentation and Detectors · Physics 2020-06-24 H. Neog , R. Mahapatra , N. Mirabolfathi , M. Platt , A. Jastram , G. Agnolet , A. Kubik , H. Chen , B. Mohanty