Related papers: Constraints on Light WIMPs from SuperCDMS
We report on a search for Weakly Interacting Massive Particles (WIMPs) using 278.8 days of data collected with the XENON1T experiment at LNGS. XENON1T utilizes a liquid xenon time projection chamber with a fiducial mass of $(1.30 \pm 0.01)$…
I report recent results and the status of the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory in Minnesota, USA. A blind analysis of data taken by 30 detectors between October 2006 and July 2007 found…
We perform a low-mass dark matter search using an exposure of 30\,kg$\times$yr with the XENON100 detector. By dropping the requirement of a scintillation signal and using only the ionization signal to determine the interaction energy, we…
The WIMP proposed here yields the observed abundance of dark matter, and is consistent with the current limits from direct detection, indirect detection, and collider experiments, if its mass is $\sim 72$ GeV/$c^2$. It is also consistent…
We present the results of a search for elastic scattering from galactic dark matter in the form of Weakly Interacting Massive Particles (WIMPs) in the 4-30 GeV/$c^2$ mass range. We make use of a 582 kg-day fiducial exposure from an array of…
SIMPLE (Superheated Instrument for Massive ParticLE searches) employs superheated droplet detectors (SDDs) to search for Weakly Interacting Massive Particle (WIMP) dark matter. As a result of the intrinsic SDD insensitivity to minimum…
TREX-DM is conceived to look for low-mass Weakly Interacting Massive Particles (WIMPs) using a gas Time Projection Chamber equipped with micromegas readout planes at the Canfranc Underground Laboratory. The detector can hold in the active…
CDMSlite Run 2 was a search for weakly interacting massive particles (WIMPs) with a cryogenic 600 g Ge detector operated in a high-voltage mode to optimize sensitivity to WIMPs of relatively low mass from 2 - 20 GeV/$c^2$. In this article,…
Three dark matter direct detection experiments, DAMA, COGENT and CRESST, have reported a possible signal of WIMP interaction corresponding to very light particles, close to the edge of the XENON 100 and CDMS sensitivity. Imposing the latest…
The EDELWEISS experiment has improved its sensitivity for the direct search for WIMP dark matter. In the recoil energy range relevant for WIMP masses below 10 TeV/c2, no nuclear recoils were observed in the fiducial volume of a…
The SIMPLE project uses superheated C2ClF5 liquid detectors to search for particle dark matter candidates. We report the results of the first stage exposure (14.1 kgd) of its latest two-stage, Phase II run, with 15 superheated droplet…
We present the first search for bosonic super-WIMPs as keV-scale dark matter candidates performed with the GERDA experiment. GERDA is a neutrinoless double-beta decay experiment which operates high-purity germanium detectors enriched in…
This work analyzes the detection prospects for weakly interacting massive particles (WIMPs) in dark matter (DM) density spikes around nearby supermassive black holes (SMBHs) by observations in very high energy gamma-ray band. Such spikes…
We revisit the expected sensitivity of large-scale xenon detectors to Weakly Interacting Massive Particles (WIMPs). Assuming current primary noise sources can be mitigated, we find that with the present discrimination power between nuclear…
New results after 0.69 kg yr of measurement with an enriched 76Ge detector of the Heidelberg--Moscow experiment with an active mass of 2.758 kg are presented. An energy threshold of 9 keV and a background level of 0.042 counts/(kg d keV) in…
If Dark Matter is made of Weakly Interacting Massive Particles (WIMPs) with masses below $\sim$20 GeV, the corresponding nuclear recoils in mainstream WIMP experiments are of energies too close, or below, the experimental threshold. Gas…
We propose a method using solid state detectors with directional sensitivity to dark matter interactions to detect low-mass Weakly Interacting Massive Particles (WIMPs) originating from galactic sources. In spite of a large body of…
CoGeNT employs p-type point-contact (PPC) germanium detectors to search for Weakly Interacting Massive Particles (WIMPs). By virtue of its low energy threshold and ability to reject surface backgrounds, this type of device allows an…
Two germanium detectors are currently operating in the Canfranc Underground Laboratory at 2450 m.w.e looking for WIMP dark matter. One is a 2 kg 76Ge IGEX detector (RG-2) which has an energy threshold of 4 keV and a low-energy background…
The EDELWEISS-II experiment uses cryogenic heat-and-ionization Germanium detectors in order to detect the rare interactions from WIMP dark matter particles of local halo. New-generation detec- tors with an interleaved electrode geometry…