English
Related papers

Related papers: Constraints on Light WIMPs from SuperCDMS

200 papers

The Cryogenic Dark Matter Search (CDMS) employs Ge and Si detectors to search for WIMPs via their elastic-scattering interactions with nuclei while discriminating against interactions of background particles. CDMS data give limits on the…

Astrophysics · Physics 2012-08-27 CDMS Collaboration

SuperCDMS is currently operating a 10-kg array of cryogenic germanium detectors in the Soudan underground laboratory to search for weakly interacting massive particles, a leading dark matter candidate. These detectors, known as iZIPs,…

Instrumentation and Methods for Astrophysics · Physics 2019-08-13 A. J. Anderson

We report results of a search for light weakly interacting massive particle (WIMP) dark matter from the CDEX-1 experiment at the China Jinping Underground Laboratory (CJPL). Constraints on WIMP-nucleon spin-independent (SI) and…

We report the first results of a light weakly interacting massive particles (WIMPs) search from the CDEX-10 experiment with a 10 kg germanium detector array immersed in liquid nitrogen at the China Jinping Underground Laboratory with a…

We report results from searches of pseudoscalar and vector bosonic super-weakly interacting massive particles (super-WIMP) in the TEXONO experiment at the Kuo-Sheng Nuclear Power Station, using 314.15 kg days of data from $n$-type…

High Energy Physics - Experiment · Physics 2019-02-27 Manoj Kumar Singh , Lakhwinder Singh , Mehmet Agartioglu , Vivek Sharma , Venktesh Singh , Henry Tsz-king Wong

We present constraints on weakly interacting massive particles (WIMP)-nucleus scattering from the 2013 data of the Large Underground Xenon dark matter experiment, including $1.4\times10^{4}\;\mathrm{kg\; day}$ of search exposure. This new…

Cosmology and Nongalactic Astrophysics · Physics 2016-05-17 LUX Collaboration , D. S. Akerib , H. M. Araújo , X. Bai , A. J. Bailey , J. Balajthy , P. Beltrame , E. P. Bernard , A. Bernstein , T. P. Biesiadzinski , E. M. Boulton , A. Bradley , R. Bramante , S. B. Cahn , M. C. Carmona-Benitez , C. Chan , J. J. Chapman , A. A. Chiller , C. Chiller , A. Currie , J. E. Cutter , T. J. R. Davison , L. de Viveiros , A. Dobi , J. E. Y. Dobson , E. Druszkiewicz , B. N. Edwards , C. H. Faham , S. Fiorucci , R. J. Gaitskell , V. M. Gehman , C. Ghag , K. R. Gibson , M. G. D. Gilchriese , C. R. Hall , M. Hanhardt , S. J. Haselschwardt , S. A. Hertel , D. P. Hogan , M. Horn , D. Q. Huang , C. M. Ignarra , M. Ihm , R. G. Jacobsen , W. Ji , K. Kazkaz , D. Khaitan , R. Knoche , N. A. Larsen , C. Lee , B. G. Lenardo , K. T. Lesko , A. Lindote , M. I. Lopes , D. C. Malling , A. Manalaysay , R. L. Mannino , M. F. Marzioni , D. N. McKinsey , D. M. Mei , J. Mock , M. Moongweluwan , J. A. Morad , A. St. J. Murphy , C. Nehrkorn , H. N. Nelson , F. Neves , K. O`Sullivan , K. C. Oliver-Mallory , R. A. Ott , K. J. Palladino , M. Pangilinan , E. K. Pease , P. Phelps , L. Reichhart , C. Rhyne , S. Shaw , T. A. Shutt , C. Silva , V. N. Solovov , P. Sorensen , S. Stephenson , T. J. Sumner , M. Szydagis , D. J. Taylor , W. Taylor , B. P. Tennyson , P. A. Terman , D. R. Tiedt , W. H. To , M. Tripathi , L. Tvrznikova , S. Uvarov , J. R. Verbus , R. C. Webb , J. T. White , T. J. Whitis , M. S. Witherell , F. L. H. Wolfs , K. Yazdani , S. K. Young , C. Zhang

We calculate solar models including dark matter (DM) weakly-interacting massive particles (WIMPs) of mass 5-50 GeV and test these models against helioseismic constraints on sound speed, convection zone depth, convection zone helium…

Solar and Stellar Astrophysics · Physics 2010-11-08 Daniel T. Cumberbatch , Joyce. A. Guzik , Joseph Silk , L. Scott Watson , Stephen M. West

A good particle candidate for Cold Dark Matter (CDM) is the supersymmetric neutralino or more generally a weakly interacting massive particle (WIMP). The expected interaction rate of WIMPs with the detector medium in the direct detection…

Instrumentation and Methods for Astrophysics · Physics 2010-02-17 V. Kozlov

The EDELWEISS-II collaboration has performed a direct search for WIMP dark matter with an array of ten 400 g heat-and-ionization cryogenic detectors equipped with interleaved electrodes for the rejection of near-surface events. Six months…

Amplifying the phonon signal in a semiconductor dark matter detector can be accomplished by operating at high voltage bias and converting the electrostatic potential energy into Luke-Neganov phonons. This amplification method has been…

Instrumentation and Methods for Astrophysics · Physics 2015-06-03 M. Pyle , D. A. Bauer , B. Cabrera , J. Hall , R. W. Schnee , R. Basu Thakur , S. Yellin

We report results of a search for Weakly Interacting Massive Particles (WIMPs) with the Si detectors of the CDMS II experiment. This report describes a blind analysis of the first data taken with CDMS II's full complement of detectors in…

We present results of a dark matter search performed with a 0.6 kg day exposure of the DAMIC experiment at the SNOLAB underground laboratory. We measure the energy spectrum of ionization events in the bulk silicon of charge-coupled devices…

The EDELWEISS collaboration has performed a direct search for WIMP dark matter using a 320 g heat-and-ionization cryogenic Ge detector operated in a low-background environment in the Laboratoire Souterrain de Modane. No nuclear recoils are…

An ever-increasing body of evidence suggests that weakly interacting massive particles (WIMPs) constitute the bulk of the matter in the Universe. Experimental data, dimensional analysis and Standard Model particle physics are sufficient to…

High Energy Physics - Phenomenology · Physics 2007-05-23 F. Halzen

We report a new search of weakly interacting massive particles (WIMPs) using the combined low background data sets in 2016 and 2017 from the PandaX-II experiment in China. The latest data set contains a new exposure of 77.1 live day, with…

Data taken during the final shallow-site run of the first tower of the Cryogenic Dark Matter Search (CDMS II) detectors have been reanalyzed with improved sensitivity to small energy depositions. Four ~224 g germanium and two ~105 g silicon…

CDEX-50 is a next-generation project of the China Dark Matter Experiment (CDEX) that aims to search for dark matter using a 50-kg germanium detector array. This paper comprises a thorough summary of the CDEX-50 dark matter experiment,…

Light WIMPs are dark matter particle candidates with weak scale interaction with the known particles, and mass in the GeV to 10's of GeV range. Hints of light WIMPs have appeared in several dark matter searches in the last decade. The…

High Energy Physics - Phenomenology · Physics 2017-12-13 Graciela B. Gelmini

For many working in particle physics and cosmology successful discovery and characterisation of the new particles that most likely explain the non-baryonic cold dark matter, known to comprise the majority of matter in the Universe, would be…

Astrophysics · Physics 2009-06-23 N. J. Spooner

An energy threshold of (220+-10) eV was achieved at an efficiency of 50% with a four-channel ultra-low-energy germanium detector each with an active mass of 5 g. This provides a unique probe to WIMP dark matter with mass below 10 GeV. With…

High Energy Physics - Experiment · Physics 2009-03-24 TEXONO Collaboration , S. T. Lin