We report preliminary $R$ values for all 85 energy points scanned in the energy region of 2-5 GeV with the upgraded Beijing Spectrometer (BESII) at the Beijing Electron Positron Collider (BEPC). The typical uncertainty on the R values we…

High Energy Physics - Experiment · Physics 2007-05-23 Z. G. Zhao

For the upgrade of the inner tracker of the BESIII spectrometer, planned for 2018, a lightweight tracker based on an innovative Cylindrical Gas Electron Multiplier (CGEM) detector is now under development. The analogue readout of the CGEM…

Time and charge measurements over a large dynamic range from 1 Photo Electron (P.E.) to 4000 P.E. are required for the Water Cherenkov Detector Array (WCDA), which is one of the key components in the Large High Altitude Air Shower…

Instrumentation and Detectors · Physics 2019-09-26 Yu Liang , Lei Zhao , Yuxiang Guo , Jiajun Qin , Yunfang Yang , Boyu Cheng , Shubin Liu , Qi An

In the readout electronics of the Water Cerenkov Detector Array (WCDA) in the Large High Altitude Air Shower Observatory (LHAASO), both high-resolution charge and time measurement are required over a dynamic range from 1 photoelectron…

Instrumentation and Detectors · Physics 2019-07-09 Cong Ma , Lei Zhao , Ruoshi Dong , Zouyi Jiang , Shaoping Chu , Xingshun Gao , Shubin Liu , Qi An

The search for neutrinoless double beta decay requires increasingly advanced methods of background reduction. A bold approach to solving this problem, in experiments using Xe-136, is to extract and identify the daughter Ba-136 ion produced…

Instrumentation and Detectors · Physics 2019-10-07 K. Murray , J. Dilling , R. Gornea , Y. Ito , T. Koffas , A. A. Kwiatkowski , Y. Lan , M. P. Reiter , V. Varentsov , T. Brunner

Time of flight of a minimum ionizing particle along a fixed base has been measured with a 100 ps accuracy by means of a Dielectric Resistive Plate Chamber (DRPC) with 4 x 0.3 mm gas gaps. DRPC timing characteristics have been studied with…

Instrumentation and Detectors · Physics 2007-05-23 A. Akindinov , V. Golovin , A. Martemiyanov , V. Petrov , V. Plotnikov , A. Smirnitsky , K. Voloshin

A high-granularity crystal calorimeter (HGCCAL) has been proposed for the future Circular Electron Positron Collider (CEPC). This study investigates the time resolution of various crystal - Silicon Photomultiplier (SiPM) detection units for…

Instrumentation and Detectors · Physics 2025-03-24 Zhiyu Zhao , Dejing Du , Yong Liu , Jiyuan Chen , Junfeng Chen , Fangyi Guo , Shu Li , Baohua Qi

Optical readout of GEM based devices by means of high granularity and low noise CMOS sensors allows to obtain very interesting tracking performance. Space resolution of the order of tens of $\mu$m were measured on the GEM plane along with…

We propose to search for millicharged particles at the BESIII detector which is operated at the Beijing Electron Positron Collider. We compute the monophoton signal events at the BESIII detector due to millicharged particle production, as…

High Energy Physics - Phenomenology · Physics 2019-01-09 Zuowei Liu , Yu Zhang

A hybrid readout Time Projection Chamber (TPC) has a simultaneous optical- and charge readout. The optical readout provides 2D images of particle tracks in the active volume, whilst the charge readout provides additional information on the…

Instrumentation and Detectors · Physics 2022-12-21 Alexander Deisting

A Multi-gap Resistive Plate Chamber (MRPC) equipped with heaters to improve the counting rate capability was designed for the BM@N experiment in Dubna. The measurements were performed using a muon beam at IHEP U-70 accelerator in Protvino.…

Instrumentation and Detectors · Physics 2018-12-26 N. A. Kuzmin , E. A. Ladygin , V. P. Ladygin , Yu. P. Petukhov , S. Ya. Sychkov , A. A. Semak , M. N. Ukhanov , E. A. Usenko

The extension of data acquisition for the BEijing Spectrometer (BESIII) experiment until at least 2030 has resulted in upgrades to both the accelerator and the detector. An innovative Cylindrical Gas Electron Multiplier (CGEM) is under…

Instrumentation and Detectors · Physics 2022-12-22 Alberto Bortone

We present the implementation and verification of an in-pixel automatic threshold calibration circuit for the CMS Endcap Timing Layer (ETL) in the High-Luminosity LHC upgrade. The discriminator threshold of the ETL readout chip (ETROC)…

Instrumentation and Detectors · Physics 2021-10-04 H. Sun , D. Gong , C. Edwards , G. Huang , X. Huang , C. Liu , T. Liu , T. Liu , J. Olsen , Q. Sun , J. Wu , J. Ye , L. Zhang , W. Zhang

With the development of the circular collider, it is necessary to make accurate physics experimental measurements of particle properties at higher luminosity $Z$ pole. Micro-pattern gaseous detectors (MPGDs), which contain Gaseous Electron…

Instrumentation and Detectors · Physics 2021-09-22 Zhiyang Yuan , Huirong Qi , Yue Chang , Ye Wu , Hongyu Zhang , Jian Zhang , Yuanbo Chen , Yiming Cai , Yulan Li , Zhi Deng , Hui Gong

We developed a prototype time projection chamber using gas electron multipliers (GEM-TPC) for high energy heavy ion collision experiments. To investigate its performance, we conducted a beam test with 3 kinds of gases (Ar(90%)-CH4(10%),…

Instrumentation and Detectors · Physics 2008-11-26 S. X. Oda , H. Hamagaki , K. Ozawa , M. Inuzuka , T. Sakaguchi , T. Isobe , T. Gunji , Y. Morino , S. Saito , Y. L. Yamaguchi , S. Sawada , S. Yokkaichi

A pico-second timing (PIST) front-end electronic chip has been developed using $55~\mathrm{nm}$ CMOS technology for future electron-positron collider experiments (namely Higgs factories). Extensive tests have been performed to evaluate the…

Instrumentation and Detectors · Physics 2024-02-06 Xin Xia , Dejing Du , Xiaoshan Jiang , Yong Liu , Bo Lu , Junguang Lyu , Baohua Qi , Manqi Ruan , Xiongbo Yan

Plastic scintillators are widely used in particle detectors when precise timing information is required. As a basis for comparing different detectors we use such a characteristic as the time resolution per 1MeV detected energy, i.e. the…

Instrumentation and Detectors · Physics 2021-09-08 Alexey Stoykov , Tigran Rostomyan

The Time-of-Flight system is a proposed addition to the STAR detector currently installed at RHIC. The proposal is based on a new technology called the Multi-gap Resistive Plate Chamber (MRPC), and consists of approximately 23,000 channels…

Nuclear Experiment · Physics 2007-05-23 Joachim Schambach

This work explores the combination of liquid xenon as a scintillating medium and silicon photomultipliers as a readout in Positron Emission Tomography (PET) for enhanced Time-Of-Flight resolution. We present the results of our first…

This paper will discuss the design and construction of BESIII, which is designed to study physics in the tau-charm energy region utilizing the new high luminosity BEPCII double ring e+e- collider. The expected performance will be given…

Instrumentation and Detectors · Physics 2012-08-27 The BESIII Collaboration