Related papers: Sinogram constrained TV-minimization for metal art…
Total variation(TV) regularization is applied to X-Ray computed tomography(CT) in an effort to reduce metal artifacts. Tikhonov regularization with $L^2$ data fidelity term and total variation regularization is augmented in this novel model…
The primal-dual optimization algorithm developed in Chambolle and Pock (CP), 2011 is applied to various convex optimization problems of interest in computed tomography (CT) image reconstruction. This algorithm allows for rapid prototyping…
Metal objects pose a significant challenge in cone-beam computed tomography, as their strong and energy-dependent X-ray attenuation leads to inconsistent projections and severe streaking and shading artifacts in reconstructed images. These…
X-ray computed tomography (CT) is widely utilized in the medical, industrial, and other fields to nondestructively generate three-dimensional structural images of objects. However, CT images are often affected by various artifacts, with…
Computed tomography (CT) has been developed as a non-destructive technique for observing minute internal images of samples. It has been difficult to obtain photo-realistic (clean or clear) CT images due to various unwanted artifacts…
Metallic implants introduce severe artifacts in CT images, which degrades the image quality. It is an effective method to reduce metal artifacts by replacing the metal affected projection with the forward projection of a prior image. How to…
Computed tomography (CT) has been widely used for medical diagnosis, assessment, and therapy planning and guidance. In reality, CT images may be affected adversely in the presence of metallic objects, which could lead to severe metal…
A conventional approach to computed tomography (CT) or cone beam CT (CBCT) metal artifact reduction is to replace the X-ray projection data within the metal trace with synthesized data. However, existing projection or sinogram completion…
Recent CT Metal Artifacts Reduction (MAR) methods are often based on image-to-image convolutional neural networks for adjustment of corrupted sinograms or images themselves. In this paper, we are exploring the capabilities of a multi-domain…
Metal artifact reduction (MAR) in computed tomography (CT) is a notoriously challenging task because the artifacts are structured and non-local in the image domain. However, they are inherently local in the sinogram domain. Thus, one…
In computed tomography (CT), metal implants increase the inconsistencies between the measured data and the linear attenuation assumption made by analytic CT reconstruction algorithms. The inconsistencies give rise to dark and bright bands…
We introduce a new CT image reconstruction algorithm that is less affected by various artifacts. The new reconstruction algorithm is a method of minimizing the difference between synchrotron X-ray tomography data and sinograms generated…
Computed Tomography (CT) reconstruction is a fundamental component to a wide variety of applications ranging from security, to healthcare. The classical techniques require measuring projections, called sinograms, from a full 180$^\circ$…
As the medical usage of computed tomography (CT) continues to grow, the radiation dose should remain at a low level to reduce the health risks. Therefore, there is an increasing need for algorithms that can reconstruct high-quality images…
This paper presents a two-stage method for beam hardening artifact correction of dental cone beam computerized tomography (CBCT). The proposed artifact reduction method is designed to improve the quality of maxillofacial imaging, where soft…
This article is intended to supplement our 2015 paper in Medical Physics titled "Noise properties of CT images reconstructed by use of constrained total-variation, data-discrepancy minimization", in which ordered subsets methods were…
X-ray computed tomography (CT) is one of widely used diagnostic tools for medical and dental tomographic imaging of the human body. However, the standard filtered backprojection reconstruction method requires the complete knowledge of the…
Iterative image reconstruction (IIR) algorithms in Computed Tomography (CT) are based on algorithms for solving a particular optimization problem. Design of the IIR algorithm, therefore, is aided by knowledge of the solution to the…
Metal artifacts is a major challenge in computed tomography (CT) imaging, significantly degrading image quality and making accurate diagnosis difficult. However, previous methods either require prior knowledge of the location of metal…
Inconsistent responses of X-ray detector elements lead to stripe artifacts in the sinogram data, which manifest as ring artifacts in the reconstructed CT images, severely degrading image quality. This paper proposes a method for correcting…