Related papers: Analytic Modeling, Simulation and Interpretation o…
After a general introduction, the basic principles of wake-field and beamcoupling- impedance computations are explained. This includes time domain, frequency domain, and methods that do not include excitations by means of a particle beam.…
The coaxial wire method is a common and appreciated technique to assess the beam coupling impedance of an accelerator element from scattering parameters. Nevertheless, the results obtained from wire measurements could be inaccurate due to…
An analytical method is developed for calculating the geometric wakefield and impedances of an ultrarelativistic beam propagating on- and off-axis through an axially symmetric geometry with slowly varying circular cross-section, such as a…
Coaxial wire measurements have provided a simple and effective way to measure the beam coupling impedance of accelerator structures for a number of years. It has been known how to measure the longitudinal and dipolar transverse impedance…
In many cases beam coupling impedances or wake fields are calculated with computer simulator such as CST Studio Suite, GdfidL Electromagnetic Field Simulator and so on. But evaluation with the stretched-wire method is still very useful by…
Slender beam-like structures frequently occur in engineering applications and often interact at discrete locations through joints or connectors. Accurate modeling of such interactions is particularly challenging when different numerical…
The beam coupling impedances of small obstacles protruding inside the vacuum chamber of an accelerator are calculated analytically at frequencies for which the wavelength is large compared to a typical size of the obstacle. Simple formulas…
The beam coupling impedances of small discontinuities of an accelerator vacuum chamber have been calculated [e.g., S.S. Kurennoy, R.L. Gluckstern, and G.V. Stupakov, Phys. Rev. E 52, 4354 (1995)] for ultrarelativistic beams using the Bethe…
In experimental physics, it is essential to understand electromagnetic (EM) wave scattering across EM spectrum, from radio waves to X-rays, and is pivotal in driving photonics innovations. Recent advancements have uncovered phenomena like…
The longitudinal and transverse beam coupling impedance of the first final TOTEM Roman Pot unit has been measured in the laboratory with the wire method. For the evaluation of transverse impedance the wire position has been kept constant,…
Linear electromagnetic wave scattering systems can be characterized by an impedance matrix that relates the voltages and currents at the ports of the system. When the system size becomes greater than the wavelength of the fields involved,…
The beam coupling impedances of small axisymmetric obstacles having a semi-elliptical cross section along the beam in the vacuum chamber of an accelerator are calculated at frequencies for which the wavelength is large compared to a typical…
I investigate the scattering properties of transformation devices as the traditional impedance matching criteria are altered. This is demonstrated using simple theory and augmented by numerical simulations that investigate the role of…
In particle accelerators, pumping holes in a vacuum chamber can be a source of unwanted broadband coupling impedance, leading to beam instabilities. Analytical methods have been previously developed to estimate the impedance of holes in…
In this paper we present several techniques for characterizing longitudinal impedances based on transient measurements of the growth rates and tune shifts of unstable coupled-bunch modes. These techniques are applicable to measurement of…
We propose the design of an impedance matching acoustic bend in this article. The bending structure is composed of sub-wavelength unit cells with perforated plates and side pipes, whose mass density and bulk modulus can be tuned…
The time-resolved electron beam envelope parameters including sectional distribution and position are important and necessary for the study of beam transmission characteristics in the magnetic field and verifying the magnetic field setup…
Many advanced techniques have been developed, tested and implemented in the last decades in almost all circular accelerators across the world to measure the linear optics. However, the greater availability and accuracy of beam diagnostics…
For some synchrotron light source beamline applications, a round beam is preferable to a flat one. A conventional method of obtaining round beam in an electron storage ring is to shift its tune close to a linear difference resonance. The…
Random matrix theory (RMT) successfully predicts universal statistical properties of complicated wave scattering systems in the semiclassical limit, while the random coupling model offers a complete statistical model with a simple additive…