English
Related papers

Related papers: ILD SiW ECAL and sDHCAL dimension-performance opti…

200 papers

The International Large Detector (ILD) is a proposed detector for the International Linear Collider (ILC). It has been designed to achieve an excellent jet energy resolution by using Particle Flow Algorithms (PFA), which rely on the ability…

Calorimeters with silicon detectors have many unique features and are proposed for several world-leading experiments. We describe the R&D program of the large scale detector element with up to 12 000 readout channels for the International…

Instrumentation and Detectors · Physics 2018-04-18 V. Balagura

The long slab is a new prototype for the SiW-Ecal, a silicon tungsten electromagnetic calorimeter for the ILD detector of the future International Linear Collider. This new prototype has been designed to demonstrate the ability to build a…

A highly granular silicon-tungsten electromagnetic calorimeter (SiW-ECAL) is the reference design of the ECAL for International Large Detector (ILD) concept, one of the two detector concepts for the detector(s) at the future International…

Instrumentation and Detectors · Physics 2020-04-28 Adrian Irles

The International Large Detector (ILD) is a concept for a detector at the International Linear Collider, ILC. The ILC will collide electrons and positrons at energies of initially 500 GeV, upgradeable to 1 TeV. The ILC has an ambitious…

High Energy Physics - Experiment · Physics 2012-08-27 The ILD Concept Group

The first technological SDHCAL prototype having been successfully tested, a new phase of R&D, to validate completely the SDHCAL option for the International Linear Detector (ILD) project of the International Linear Collider (ILC), has…

Instrumentation and Detectors · Physics 2016-08-24 Antoine Pingault

The International Large Detector, ILD, is a detector concept which has been developed for the electron-positron collider ILC. The detector has been optimized for precision physics in a range of energies between 90 GeV and 1 TeV. ILD…

Instrumentation and Detectors · Physics 2019-12-11 The ILD Collaboration , contact Ties Behnke

The International Large Detector, ILD, is a detector concept for an experiment at a future high energy lepton collider. The detector has been optimised for precision physics in a range of energies from 90~GeV to about 1~TeV. ILD features a…

High Energy Physics - Experiment · Physics 2025-06-09 H. Abramowicz , D. Ahmadi , J. Alcaraz , O. Alonso , L. Andricek , J. Anguiano , O. Arquero , F. Arteche , D. Attie , O. Bach , M. Basso , J. Baudot , A. Bean , T. Behnke , A. Bellerive , Y. Benhammou , M. Berggren , G. Bertolone , M. Besancon , A. Besson , O. Bezshyyko , G. Blazey , B. Bliewert , J. Bonis , R. Bosley , V. Boudry , C. Bourgeois , I. Bozovic Jelisavcic , D. Breton , J. -C. Brient , B. Brudnowski , V. Buescher , K. Buesser , P. Buhmann , M. Böhler , S. Callier , E. Calvo Alamillo , M. Cepeda , S. Chen , G. Claus , P. Colas , C. Colledani , C. Combaret , R. Cornat , F. Corriveau , J. Cvach , C. De La Taille , K. Desch , H. Diao , A. Dieguez , R. Diener , A. Dorokhov , A. Drutskoy , B. Dudar , A. Dyshkant , I. Echeverria , U. Einhaus , Z. El Bitar , A. Escalante del Valle , M. Fernandez , M. Firlej , T. Fiutowski , I. Fleck , N. Fourches , M. C. Fouz , K. Francis , C. Fu , K. Fujii , T. Fusayasu , J. Fuster , K. Gadow , F. Gaede , J. Galindo , A. Gallas , S. Ganjour , E. Garutti , I. Giomataris , M. Goffe , A. Gonnin , F. González , O. Gonzalez Lopez , I. Gregor , G. Grenier , P. Göttlicher , F. Hartjes , J. Heilman , C. Hensel , S. Hidalgo , A. Himmi , Y. Horii , R. Hosokawa , C. Huo-Guo , M. Idzik , M. Iglesias , F. Ikeda , A. Irles , A. Ishikawa , M. Iwasaki , K. Jaaskelainen , R. Jaramillo , D. Jeans , J. Jeglot , L. Jönsson , G. Kacarevic , M. Kachel , J. Kalinowski , J. Kaminski , Y. Kamiya , T. Kamiyama , Y. Kato , K. Kawagoe , S. A. Khan , J. Klamka , P. Kluit , M. Kobayashi , K. Kong , A. Korol , P. Koppenburg , K. Krüger , M. Kuriki , J. Kvasnicka , D. Lacour , I. Laktineh , A. Laudrain , F. LeDiberder , A. Levy , I. Levy , W. Li , B. List , J. List , J. Liu , A. Lopez Virto , M. Lopez , Y. Lu , B. Lundberg , J. Maalmi , B. Madison , T. Madlener , A. Martens , S. Martens , I. Masamune , L. Masetti , H. Mathez , A. Matsushita , K. McDonald , K. Mekala , G. Milutinovic Dumbelovic , W. Minori , L. Mirabito , W. Mitaroff , V. Mitsou , U. Mjörnmark , T. Mogi , G. Moortgat-Pick , F. Morel , T. Mori , S. Morimasa , J. Moron , D. Moya , T. Murata , E. Musumeci , J. Márquez Hernández , J. Nakajima , E. Nakano , J. Nanni , S. Narita , J. Nilsson , J. Ninkovic , D. Ntounis , T. Nunez , H. Ogawa , K. Oikawa , Y. Okugawa , T. Omori , H. Ono , W. Ootani , C. Orero , A. Oskarsson , L. Osterman , Q. Ouyang , T. Pasquier , G. Pellegrini , H. Pham , J. Piedrafita , I. Polak , A. Pradas , V. Prahl , T. Price , J. Puerta Pelayo , R. Pöschl , H. Qi , Y. Radkhorrami , G. Raven , L. Reichenbach , M. Reinecke , E. Reynolds , F. Richard , R. Richter , S. Ritter , C. Rogan , J. Rolph , A. Rosmanitz , C. Royon , M. Ruan , S. Rudrabhatla , A. Ruiz-Jimeno , A. Sajbel , R. Sakakibara , I. Salehinia , T. Sanuki , H. Sato , C. Schmitt , T. Schoerner-Sadenius , M. Schumacher , V. Schwan , O. Schäfer , F. Sefkow , T. Seino , S. Senyukov , R. Settles , Z. Shen , A. Shoji , F. Simon , I. Smiljanic , M. Specht , T. Suehara , R. Sugawara , A. Sugiyama , Z. Sun , P. Svihra , K. Swientek , T. Takahashi , T. Takatsu , T. Takeshita , S. Tapprogge , P. Terlecki , A. Thiebault , J. Tian , J. Timmermans , M. Titov , L. Tomasek , J. Torndal , B. Tuchming , M. Tytgat , W. Vaginay , I. Valin , C. Vallee , R. van Kooten , H. van der Graaf , C. Vernieri , I. Vidakovic , H. Videau , I. Vila , A. Vilà , M. Vos , N. Vukasinovic , J. Wang , R. Wanke , K. Watanabe , T. Watanabe , N. Watson , J. Wellhausen , U. Werthenbach , G. Wilson , M. Wing , A. Winter , M. Winter , H. Yamamoto , K. Yamamoto , R. Yonamine , T. Yonemoto , J. Zalesak , A. F. Zarnecki , C. Zeitnitz , K. Zembaczynski , D. Zerwas , Y. Zhang , F. Zomer , V. Zutshi

The ILD detector is proposed for an electron-positron collider with collision centre-of-mass energies from 90~\GeV~to about 1~\TeV. It has been developed over the last 10 years by an international team of scientists with the goal to design…

Instrumentation and Detectors · Physics 2020-03-04 The ILD Collaboration

International Large Detector (ILD) adopts Particle Flow Algorithm (PFA) for precise measurement of multiple jets. The electromagnetic calorimeter (ECAL) of ILD has two candidates sensor technologies for PFA, which are pixelized silicon…

A highly granular silicon-tungsten electromagnetic calorimeter (SiW-ECAL) is the reference design of the ECAL of the International Large Detector (ILD) concept, one of the two detector concepts for the detector(s) at the future…

Instrumentation and Detectors · Physics 2020-06-17 D. Breton , A. Irles , J. Jeglot , J. Maalmi , R. Pöschl , D. Zerwas

A highly granular silicon-tungsten electromagnetic calorimeter (SiW-ECAL) is the reference design of the ECAL for International Large Detector concept, one of the two detector concepts for the future International Linear Collider.…

Instrumentation and Detectors · Physics 2021-09-03 Fabricio Jimenez Morales

The ILD Si-W ECAL is a sampling calorimeter with tungsten absorber and highly segmented silicon layers for the International Large Detector (ILD), one of the two detector concepts for the International Linear Collider. SKIROC2 is an ASIC…

Excellent jet energy measurement is important at the International Linear Collider (ILC) because most of interesting physics processes decay into multi-jet final states. We employ a particle flow method to reconstruct particles, hence…

The SiD concept is one of two proposed detectors to be mounted at the interaction region of the International Linear Collider (ILC). A substantial ILC background arises from low transverse momentum $\mathrm{e}^{+}\mathrm{e}^{-}$ pairs…

Instrumentation and Detectors · Physics 2016-09-27 Timothy Barklow , Luc d`Hautuille , Christopher Milke , Bruce Schumm , Anne Schütz , Marcel Stanitzki , Jan Strube

This work presents the status and plans of the International Large Detector (ILD) concept, one of the most detailed and comprehensive detector concepts for a future Higgs factory. Most hardware groups have demonstrated ILD's performance…

High Energy Physics - Experiment · Physics 2023-11-16 Ulrich Einhaus

LumiCal will be the luminosity calorimeter for the proposed International Large Detector of the International Linear Collider (ILC). The ILC physics program requires the integrated luminosity to be measured with a relative precision on the…

The CALICE Analogue Hadron CALorimeter (AHCAL) at the International Linear Collider (ILC) is a high-granularity hadron calorimeter based on scintillator tiles readout by MPPCs. Toward the construction of ILC, the optimization of the AHCAL…

Instrumentation and Detectors · Physics 2019-04-08 Naoki Tsuji

The basic prototype of a tile hadron calorimeter (HCAL) for the International Linear Collider (ILC) has been realised and extensively tested. A major aspect of the proposed concept is the improvement of the jet energy resolution by…

Instrumentation and Detectors · Physics 2016-10-10 Aliakbar Ebrahimi

The Particle Flow Algorithms adopted for future $e^{+}e^{-}$ colliders detectors and phase-II CMS upgrade require very high granularity calorimeters to deconvolve the individual contributions of particles in jets. This is especially true…

Instrumentation and Detectors · Physics 2017-11-27 Kostiantyn Shpak
‹ Prev 1 2 3 10 Next ›