English
Related papers

Related papers: Precision spectroscopy technique for dipole allowe…

200 papers

We report frequency measurement of the clock transition in an 115In+ ion sympathetically-cooled with Ca+ ions in a linear rf trap. The Ca+ ions are used as a probe of the external electromagnetic field and as the coolant for preparing the…

Atomic Physics · Physics 2017-06-07 Nozomi Ohtsubo , Ying Li , Kensuke Matsubara , Tetsuya Ido , Kazuhiro Hayasaka

Trapped diatomic molecular ions could prove to be a sensitive probe for a permanent electron electric dipole moment (eEDM). We propose to use a ground or metastable $^3\Delta_1$ level, due to its high polarizability and large EDM…

We demonstrate how quantum entanglement can be used for precision frequency measurements with trapped ions. In particular, we show how to suppress linear Zeeman shifts in optical frequency measurements by using maximally entangled states of…

Quantum Physics · Physics 2007-05-23 C. F. Roos

We report on the frequency stabilization of a 739 nm Ti:sapphire laser to a hyperfine component of the $^{127}I_{2}$ B(1)-X(11) P(70) transition using acousto-optic modulation transfer spectroscopy (MTS). A frequency stability of…

Atomic Physics · Physics 2024-06-21 Hao Wu , PengFei Lu , Yang Liu , JiangYong Hu , QiFeng Lao , XinXin Rao , LunHua Deng , Feng Zhu , Le Luo

We report on a precision measurement of the differential static scalar polarizability $\Delta\alpha_0$ of the ${}^{2}\!S_{1/2} \rightarrow {}^{2}\!D_{5/2}$ optical clock transition in the $^{88}$Sr$^{+}$ ion. The polarizability was…

Atomic Physics · Physics 2025-07-04 T. Lindvall , K. J. Hanhijärvi , T. Fordell , A. E. Wallin

We demonstrate a simple method for the determination of the magnetic field in an ion trap using laser-cooled Be+ ions. The method is not based on magnetic resonance and thus does not require delivering radiofrequency (RF) radiation to the…

Quantum Physics · Physics 2015-06-23 Jianwei Shen , Andrii Borodin , Stephan Schiller

We report a frequency measurement of the clock transition of a single ^40Ca^+ ion trapped and laser cooled in a miniature ring Paul trap with 10^-15 level uncertainty. In the measurement, we used an optical frequency comb referenced to a…

Atomic Physics · Physics 2015-06-03 Y. Huang , J. Cao , P. Liu , K. Liang , B. Ou , H. Guan , X. Huang , T. Li , K. Gao

We report sympathetic cooling of $^{113}$Cd$^+$ by laser-cooled $^{40}$Ca$^+$ in a linear Paul trap for microwave clocks. Long-term low-temperature confinement of $^{113}$Cd$^+$ ions was achieved. The temperature of these ions was measured…

Atomic Physics · Physics 2020-02-13 J. Z. Han , H. R. Qin , L. M. Guo , N. C. Xin , H. X. Hu , Y. M. Yu , V. A. Dzuba , J. W. Zhang , L. J. Wang

Symmetry adaptation techniques are applied to the determination of the intensity of two-photon absorption transitions, between Stark levels of configurations with opposite parities, for transition ions in finite symmetry environments. The…

Atomic and Molecular Clusters · Physics 2007-05-23 M. Daoud , M. Kibler

Cooling of particles to mK-temperatures is essential for a variety of experiments with trapped charged particles. However, many species of interest lack suitable electronic transitions for direct laser cooling. We study theoretically the…

We demonstrate a method of micromotion minimization of a trapped ion in a linear Paul trap based on the precision measurement of the ion trapping position displacement due to a stray electric field in the radial plane by ion fluorescence…

Atomic Physics · Physics 2021-04-01 Ryoichi Saito , Kota Saito , Takashi Mukaiyama

Superionic conductors, or solid-state ion-conductors surpassing 0.01 S/cm in conductivity, can enable more energy dense batteries, robust artificial ion pumps, and optimized fuel cells. However, tailoring superionic conductors require…

Instrumentation and Detectors · Physics 2024-07-23 Kim H. Pham , Scott K. Cushing

Ultraviolet (UV) diode lasers are widely used in many photonics applications. But their frequency stabilization schemes are not as mature as frequency-doubling lasers, mainly due to some limitations in the UV spectral region. Here we…

We describe the design and realization of a scheme for uv laser spectroscopy of singly-ionized iron (Fe II) with very high resolution. A buffer-gas cooled laser ablation source is used to provide a plasma close to room temperature with a…

Atomic Physics · Physics 2009-11-13 M Ascoli , E E Eyler , D Kawall , David DeMille

Nonlinear spectroscopy employs a series of laser pulses to interrogate dynamics in large interacting many-body systems, and has become a highly successful method for experiments in chemical physics. Current quantum optical experiments…

Quantum Physics · Physics 2016-10-19 Frank Schlawin , Manuel Gessner , Shaul Mukamel , Andreas Buchleitner

We present a method of laser frequency stabilization based on the linear dichroism signal in a transverse magnetic field. The method is similar to the DAVLL (Dichroic Atomic Vapor Laser Lock) method. It differs from DAVLL and from its…

Atomic Physics · Physics 2026-04-28 M. V. Petrenko , A. S. Pazgalev , A. K. Vershovskii

We demonstrate spectroscopy and thermometry of individual motional modes in a mesoscopic 2D ion array using entanglement-induced decoherence as a method of transduction. Our system is a $\sim$400 $\mu$m-diameter planar crystal of several…

We report on the development and performance evaluation of an ultra-stable clock laser for an $\rm ^{27}Al^+$ optical clock. The thermal noise limited ultra-stable laser is developed based on a 30 cm long ultra-stable cavity. Three…

Ground state laser cooling of a single trapped ion is achieved using a technique which tailors the absorption profile for the cooling laser by exploiting electromagnetically induced transparency in the Zeeman structure of a dipole…

Quantum Physics · Physics 2009-11-06 C. F. Roos , D. Leibfried , A. Mundt , F. Schmidt-Kaler , J. Eschner , R. Blatt

We study modulation spectroscopy of the potassium D2 transitions at 766.7 nm. The vapour pressure, controlled by heating a commercial reference cell, is optimized using conventional saturated absorption spectroscopy. Subsequent heterodyne…

Atomic Physics · Physics 2012-05-03 L. Mudarikwa , K. Pahwa , J. Goldwin