Related papers: A Cryogenic Infrared Calibration Target
We developed an apparatus to couple a 50-micrometer diameter whispering-gallery silica microtoroidal resonator in a helium-4 cryostat using a straight optical tapered-fiber at 1550nm wavelength. On a top-loading probe specifically adapted…
We apply the standard photovoltaic technique of texturing to reduce the reflectivity of silicon cryogenic calorimetric light detectors. In the case of photons with random incidence angles, absorption is compatible with the increase in…
Cooling down test masses to cryogenic temperatures is a way to reduce the thermal noise of gravitational wave detectors. Crystalline materials are considered the most promising materials for fabricating cryogenic test masses and their…
Through passively emitting excess heat to the outer space, radiative cooling has been demonstrated as an efficient way for energy saving applications. Selective surface with unity emittance only within the atmospheric window as well as zero…
We report on the scintillation characterization of a 1 cm^3 CsI(Tl) crystal coupled to a 6 x 6 mm^2 SiPM read out with a custom transimpedance amplifier at cryogenic temperatures. The crystal was prepared with optical-grade surfaces and…
Improvement of tool reliability and uptime is a current focus in development of extreme ultraviolet lithography. The lifetime of collection mirrors for extreme ultraviolet light in tin-based plasma light sources is limited considerably by…
We have designed and characterized a cryogenic amplifier for use in $^3$He NMR spectrometry. The amplifier, with a power consumption of $\sim 2.5$ mW, works at temperatures down to 4~K. It has a hi-impedance input for measuring a signal…
We design a spectrally resolved interferometer to measure the refractive index of transparent samples over a broad spectral range between 400 and 550 nm. The measuring device consists of a Michelson interferometer whose output is analysed…
We have designed, fabricated and characterized absorptive thermal blocking filters for cryogenic microwave applications. The transmission line filter's input characteristic impedance is designed to match $50\,\Omega$ and its response has…
Providing a background discrimination tool is crucial for enhancing the sensitivity of next-generation experiments searching for neutrinoless double- beta decay. The development of high-sensitivity (< 20 eV RMS) cryogenic light detectors…
Future gravitational wave detectors (GWDs) such as Advanced LIGO upgrades and the Einstein Telescope are planned to operate at cryogenic temperatures using crystalline silicon (cSi) test-mass mirrors at an operation wavelength of 1550 nm.…
We report the mirror suspension design for Large-scale Cryogenic Gravitational wave Telescope, KAGRA, during bKAGRA Phase 1. Mirror thermal noise is one of the fundamental noises for room-temperature gravitational-wave detectors such as…
Aims. We present a 0.2--200 keV broad-band study of absorbed AGN observed with INTEGRAL, XMM-Newton, Chandra and ASCA to investigate the continuum shape and the absorbing/reflecting medium properties. Methods. The sources are selected in…
We investigated the far- and mid-infrared reflectivity (20-6000 wavenumber) of several pure and doped CuGeO3 single crystals. The b-axis and c-axis optical response is presented for different temperatures between 4 K and 300 K. Moreover, a…
The frequency stability of a laser locked to an optical reference cavity is fundamentally limited by thermal noise in the cavity length. These fluctuations are linked to material dissipation, which depends both on the temperature of the…
The infrared reflectivity of a $\rm La_{0.67}Ca_{0.33}MnO_3$ single crystal is studied over a broad range of temperatures (78-340 K), magnetic fields (0-16 T), and wavenumbers (20-9000 cm$^{-1}$). The optical conductivity gradually changes…
The thermal emission of refractory plasmonic metamaterial - a titanium nitride 1D grating - is studied at high operating temperature (540 {\deg}C). By choosing a refractory material, we fabricate thermal gratings with high brightness that…
Polarized targets evolved into indispensable tools in particle and nuclear physics. However, the polarized solid target is degraded by high-intense beam irradiation, known as radiation damage due to target heating and radical generation. We…
We introduce a high performance differential dilatometer based on an all-fiber Michelson interferometer at cryogenic temperature with $10^{-10}$ resolution in $\delta L/L$. It resolve the linear thermal expansion coefficient by measuring…
A new cryogenic packaging methodology that is widely applicable to packaging any integrated photonics circuit for operation at both room temperature and cryogenic temperature is reported. The method requires only equipment and techniques…