Related papers: Microwave nanobolometer based on proximity Josephs…
We propose a detector of microwave photons which can distinguish the vacuum state, one-photon state, and the states with two or more photons. Its operation is based on the two-photon transition in a biased Josephson junction and detection…
We describe a compact calorimeter that opens ultra-low temperature heat capacity studies of small metal crystals in moderate magnetic fields. The performance is demonstrated on the canonical heavy Fermion metal YbRh2Si2. Thermometry is…
A calorimetric detector for minimally disruptive measurements of atomic hydrogen beams is described. The calorimeter measures heat released by the recombination of hydrogen atoms into molecules on a thin wire. As a demonstration, the…
We present a method for the measurement of a temperature differential across a single quantum dot that has transmission resonances that are separated in energy by much more than the thermal energy. We determine numerically that the method…
We report on the detection of single photons with {\lambda} = 8 {\mu}m using a superconducting hot-electron microbolometer. The sensing element is a titanium transition-edge sensor with a volume ~ 0.1 {\mu}m^3 fabricated on a silicon…
We studied noise properties of microwave signals transmitted through the cryogenic resonator. The experiments were performed with the 11.342 GHz sapphire loaded cavity resonator cooled to 6.2 K. Based on the measured transmission…
In low-dimensional systems, the combination of reduced dimensionality, strong interactions, and topology has led to a growing number of many-body quantum phenomena. Thermal transport, which is sensitive to all energy-carrying degrees of…
The energy dependent thermoelectric response of a single molecule contains valuable information about its transmission function and its excited states. However, measuring it requires devices that can efficiently heat up one side of the…
The emerging quantum technological apparatuses [1,2], such as the quantum computer [3-5], call for extreme performance in thermal engineering at the nanoscale [6]. Importantly, quantum mechanics sets a fundamental upper limit for the flow…
Detecting an itinerant microwave photon with high efficiency is an outstanding problem in microwave photonics and its applications. We present a scheme to detect an itinerant microwave photon in a transmission line via the nonlinearity…
Absorption microscopy is a powerful technique, enabling the detection of single non- fluorescent molecules at room temperature. So far, the molecular absorption has been probed optically via the attenuation of a probing laser. The…
Axions detection requires the ultimate sensitivity down to the single photon limit. In the microwave region this corresponds to energies in the yJ range. This extreme sensitivity has to be combined with an extremely low dark count rate,…
We demonstrate complete control over dynamics of a single superconducting vortex in a nanostructure which we coin the Single Vortex Box (SVB). Our device allows us to trap the vortex in a field-cooled aluminum nanosquare and expel it on…
We report on microwave optomechanics measurements performed on a nuclear adiabatic demagnetization cryostat, whose temperature is determined by accurate thermometry from below 500$~\mu$K to about 1$~$Kelvin. We describe a method for…
We propose a scheme for the detection of microwave induced photons through current-biased Josephson junction, from the point of view of the statistical decision theory. Our analysis is based on the numerical study of the zero voltage…
So far, quantum-limited power meters are not available in the microwave domain, hindering measurement of photon number in itinerant quantum states. On the one hand, single photon detectors accurately detect single photons, but saturate as…
We propose a single photon detector based on a superconducting quantum interference device (SQUID) with superconductor-normal metal-superconductor Josephson weak links. One of the two Josephson junctions is connected to an antenna, and is…
Precise measurements of the cosmic microwave background (CMB) are crucial in cosmology, because any proposed model of the universe must account for the features of this radiation. Of all CMB measurements that the scientific community has…
This paper introduces a thermal infrared detector utilizing a nano-optomechanical silicon nitride (SiN) resonator, equipped with a free-space impedance-matched (FSIM) absorber composed of a platinum (Pt) thin film, offering a broadband…
A broad range of scientific and industrial disciplines require precise optical measurements at very low light levels. Single-photon detectors combining high efficiency and high time resolution are pivotal in such experiments. By using…