Related papers: Tracking the Complex Absorption in NGC 2110 with T…
The Seyfert 1 galaxy NGC4151 is characterized by complex X-ray absorption, well described by a dual absorber, composed of a uniform mildly ionized gas and a cold system that partially covers the central source. However, in one of the 5…
We present an X-ray spectral analysis of a sample of 8 bona-fide Seyfert 2 galaxies, selected on the basis of their high $[OIII]\lambda5007$ flux, from the Ho et al. (1997) spectroscopic sample of nearby galaxies. We find that, in general,…
In this paper, a BeppoSAX observation of the bright Seyfert 2 galaxy NGC6300 is presented. The rapidly variable emission from the active nucleus is seen through a Compton-thin (NH ~ 3x10^23 atomoms/cm/cm) absorber. A Compton-reflection…
We present RXTE monitoring observations of the Seyfert 2 galaxy Mrk 348 spanning a 6 month period. The time-averaged spectrum in the 3-20 keV band shows many features characteristic of a Compton-thin Seyfert 2 galaxy, namely a hard…
IRAS 00521$-$7054 is the first Seyfert 2 in which the presence of an extremely large Fe K$\alpha$ line has been claimed. We report here on the analysis of a 100 ks Suzaku observation of the source. We confirm the existence of a very strong…
We present a study of the variations in the absorbing column density of 25 X-ray defined Seyfert 2 galaxies, as inferred from hard X-ray observations, on timescales from months to several years. We show that a significant variation of N$_H$…
The first X-ray observation of the Seyfert 2 galaxy NGC5252 is reported. ASCA collected $\sim 4000$ photons/detector enough to perform an accurate spectral analysis of this source. The luminosity of NGC5252 is L$_{\rm X}$(0.7-10 keV)…
We present a detailed study of the highly obscured active galaxy NGC 4507, performed using four Nuclear Spectroscopic Telescope Array (NuSTAR) observations carried out between May and August in 2015 (~ 130 ks in total). Using various…
The observation of the Narrow-Line Seyfert 1 galaxy IRAS13349+2438 performed by XMM-Newton European Photon Imaging Camera between 0.3-10 keV, is presented here. The broadband spectrum of the source is dominated at low energies (E < 2 keV)…
A long 280 ks observation of the Seyfert 1 galaxy NGC 3783 with XMM-Newton is reported. We focus on the oxygen line complex between 17 and 24 A as measured with the RGS spectrometers. Accurate absorption column densities and emission line…
We analyze recent simultaneous Chandra/RXTE observations of the Seyfert 2 galaxy NGC 4945. The unprecedented spatial resolution of Chandra means we are able to separate the spectra of the nucleus, starburst and superwind regions, while the…
Using the BeppoSAX observatory, we have observed a nearby LINER/Seyfert 2 galaxy, NGC 3079, which is known as an outflow galaxy and a bright H_2O-maser source. Using the PDS detector, we have revealed that the NGC 3079 nucleus suffers from…
We use the full broad-band XMM-Newton EPIC data to examine the X-ray spectrum of the nearby Seyfert 2 galaxy NGC 1068, previously shown to be complex with the X-ray continuum being a sum of components reflected/scattered from cold (neutral)…
We present BeppoSAX observations of the Seyfert 1.8 galaxy NGC1365 in the 0.1--100 keV range. The source was 6 times brighter than during an ASCA observation 3 years earlier. The 4--10 keV flux is highly variable during the BeppoSAX…
The morphology of the circumnuclear gas accreting onto supermassive black holes in Seyfert galaxies remains a topic of much debate. As the innermost regions of Active Galactic Nuclei (AGN) are spatially unresolved, X-ray spectroscopy, and…
We present results from an XMM-Newton observation of the nearby Seyfert 2 galaxy NGC5643. The nucleus exhibits a very flat X-ray continuum above 2 keV, together with a prominent K-alpha fluorescent iron line. This indicates heavy…
In about half of Seyfert galaxies, the X-ray emission is absorbed by an optically thin, ionized medium, the so-called "Warm Absorber", whose origin and location is still a matter of debate. The aims of this paper is to put more constraints…
There are several Seyfert galaxies for which there is a discrepancy between the small column of neutral hydrogen deduced from X-ray observations and the much greater column derived from the reddening of the optical/UV emission lines and…
We present an analysis of six 12 um selected Seyfert 2 galaxies that have been reported to be unabsorbed in the X-ray. By comparing the luminosities of these galaxies in the mid-IR (12um), optical ([O III]) and hard X-ray (2-10 keV), we…
We report results from a Suzaku observation of the narrow-line Seyfert 1 NGC 4051. During our observation, large amplitude rapid variability is seen and the averaged 2--10 keV flux is 8.1x10^-12 erg s^-1 cm^-2, which is several times lower…