English
Related papers

Related papers: Mathematical Modelling of Optical Coherence Tomogr…

200 papers

We demonstrate in a {\it proof-of-concept} experiment spectral-domain optical coherence tomography where steering of the optical beam that probes the sample in a transverse scan does not make use of any mechanical element. Steering is done…

Optics · Physics 2023-12-15 Daniel F. Urrego , Gerard J. Machado , Juan P. Torres

A resolution enhancement technique for optical coherence tomography (OCT), based on Generative Adversarial Networks (GANs), was developed and investigated. GANs have been previously used for resolution enhancement of photography and optical…

Image and Video Processing · Electrical Eng. & Systems 2021-01-19 Kaicheng Liang , Xinyu Liu , Si Chen , Jun Xie , Wei Qing Lee , Linbo Liu , Hwee Kuan Lee

Dispersion is a common phenomenon in optics due to the frequency dependence of the refractive index in polychromatic light. This issue, if left untreated in optical coherence tomography (OCT) imaging, leads to signal broadening of the…

Image and Video Processing · Electrical Eng. & Systems 2022-01-03 Shangbang Luo , Guy Holland , Eric Mikula , Samantha Bradford , Reza Khazaeinezhad , James V Jester , Tibor Juhasz

In Fourier-domain optical coherence tomography (OCT), the finite bandwidth of the acquisition electronics constrains the depth range and speed of the system. Circular-ranging (CR) OCT methods use optical-domain compression to surpass this…

Applied Physics · Physics 2019-11-01 Norman Lippok , Brett E. Bouma , Benjamin J. Vakoc

We present an imaging technique particularly suited to the detection of a target embedded in a strongly scattering medium. Classical imaging techniques based on the Born approximation fail in this kind of configuration because of multiply…

Classical Physics · Physics 2009-08-21 Alexandre Aubry , Arnaud Derode

Non-destructive testing (NDT) is crucial for ensuring product quality and safety across various industries. Conventional methods such as ultrasonic, terahertz, and X-ray imaging have limitations in terms of probe-contact requirement, depth…

Optical coherence tomography (OCT) is a non-invasive imaging technique that can produce images of the eye at the microscopic level. OCT image segmentation to localise retinal layer boundaries is a fundamental procedure for diagnosing and…

Computer Vision and Pattern Recognition · Computer Science 2016-09-09 Jinming Duan , Christopher Tench , Irene Gottlob , Frank Proudlock , Li Bai

We demonstrate experimentally quantum-inspired, spectral-domain intensity optical coherence tomography. We show that the technique allows for both axial resolution improvement and dispersion cancellation compared to conventional optical…

Optics · Physics 2015-03-16 Piotr Ryczkowski , Jari Turunen , Ari T. Friberg , Goëry Genty

In this paper, we present a novel concept for a multi-channel swept source optical coherence tomography (OCT) system based on photonic integrated circuits (PICs). At the core of this concept is a low-loss polarization dependent path routing…

Background: Cervical cancer seriously affects the health of the female reproductive system. Optical coherence tomography (OCT) emerged as a non-invasive, high-resolution imaging technology for cervical disease detection. However, OCT image…

Image and Video Processing · Electrical Eng. & Systems 2022-06-14 Kaiyi Chen , Qingbin Wang , Yutao Ma

Spatial resolution in optical microscopy has traditionally been treated as a fixed parameter of the optical system. Here, we present an approach to enhance transverse resolution in beam-scanned optical coherence tomography (OCT) beyond its…

Optics · Physics 2021-10-22 Nichaluk Leartprapun , Steven G. Adie

Intrinsic optical signal (IOS) imaging of the retina, also termed as optoretinography (ORG), promises a noninvasive method for objective assessment of retinal function. By providing unparalleled capability to differentiate individual layers…

Medical Physics · Physics 2022-02-22 Tae-Hoon Kim , Guangying Ma , Taeyoon Son , Xincheng Yao

Optical coherence tomography angiography (OCTA) is a non-invasive imaging technique widely used to study vascular structures and micro-circulation dynamics in the retina and choroid. OCTA has been widely used in clinics for diagnosing…

Image and Video Processing · Electrical Eng. & Systems 2025-08-26 Kejie Chen , Guanbing Gao , Xiaochun Yang , Wenbo Wang , Jing Na

Direct imaging methods recover the presence, position, and shape of the unknown obstacles in time-harmonic inverse scattering without a priori knowledge of either the physical properties or the number of disconnected components of the…

Analysis of PDEs · Mathematics 2023-11-29 General Ozochiawaeze

We demonstrate a different scheme to perform optical sectioning of a sample based on the concept of induced coherence [Zou et al., Phys. Rev. Lett. 67, 318 (1991)]. This can be viewed as a different type of optical coherence tomography…

Quantum Physics · Physics 2018-02-19 Adam Vallés , Gerard Jiménez , Luis José Salazar-Serrano , Juan P. Torres

To recover the three dimensional (3D) volumetric distribution of matter in an object, images of the object are captured from multiple directions and locations. Using these images tomographic computations extract the distribution. In highly…

Computer Vision and Pattern Recognition · Computer Science 2015-12-08 Vadim Holodovsky , Yoav Y. Schechner , Anat Levin , Aviad Levis , Amit Aides

A broad class of imaging modalities involve the resolution of an inverse-scattering problem. Among them, three-dimensional optical diffraction tomography (ODT) comes with its own challenges. These include a limited range of views, a large…

Image and Video Processing · Electrical Eng. & Systems 2020-04-20 Thanh-an Pham , Emmanuel Soubies , Ahmed Ayoub , Joowon Lim , Demetri Psaltis , Michael Unser

Optoacoustic image formation is conventionally based upon ultrasound time-of-flight readings from multiple detection positions. Herein, we exploit acoustic scattering to physically encode the position of optical absorbers in the acquired…

Biological Physics · Physics 2019-10-30 Xose Luis Dean-Ben , Ali Ozbek , Hernan Lopez-Schier , Daniel Razansky

We discuss a quantum mechanical indirect measurement method to recover a position dependent Hamilton matrix from time evolution of coherent quantum mechanical states through an object. A mathematical formulation of this inverse problem…

Mathematical Physics · Physics 2016-06-21 Joonas Ilmavirta

In this work we propose a ResNet-based universal method for speckle reduction in optical coherence tomography (OCT) images. The proposed model contains 3 main modules: Convolution-BN-ReLU, Branch and Residual module. Unlike traditional…

Computer Vision and Pattern Recognition · Computer Science 2019-03-25 Cai Ning , Shi Fei , Hu Dianlin , Chen Yang
‹ Prev 1 8 9 10 Next ›