English
Related papers

Related papers: Intensity interferometry of single x-ray pulses fr…

200 papers

The Adaptive Gain Integrating Pixel Detector (AGIPD) is a novel detector system, currently under development by a collaboration of DESY, the Paul Scherrer Institute in Switzerland, the University of Hamburg and the University of Bonn, and…

Instrumentation and Detectors · Physics 2015-06-15 J. Becker , A. Marras , A. Klyuev , F. Westermeier , U. Trunk , H. Graafsma

For experiments at the European X-Ray Free-Electron Laser (XFEL) the Adaptive Gain Integrating Pixel Detector (AGIPD) is under development. The particular requirements for the detector are a high dynamic range of 0, 1 - to more than 10E4…

Instrumentation and Detectors · Physics 2015-06-11 J. Schwandt , E. Fretwurst , R. Klanner , J. Zhang

The European XFEL, currently under construction, will produce a coherent X-ray pulse every 222 ns in pulse trains of up to 2700 pulses. In conjunction with the fast 2D area detectors currently under development, it will be possible to…

Instrumentation and Detectors · Physics 2011-11-17 Julian Becker , Christian Gutt , Heinz Graafsma

The Adaptive Gain Integrating Pixel Detector (AGIPD) is an x-ray imager, custom designed for the European x-ray Free-Electron Laser (XFEL). It is a fast, low noise integrating detector, with an adaptive gain amplifier per pixel. This has an…

The European X-ray Free Electron Laser (XFEL) is a new research facility currently under construction in Hamburg, Germany. With a pulse length of less than 100 fs and an extremely high luminosity of 27000 flashes per second the European…

The European X-ray Free Electron Laser (XFEL), currently being constructed in Hamburg and planning to be operational in 2017 for users, will deliver 27,000 fully coherent, high brilliance X-ray pulses per second with duration less than 100…

Instrumentation and Detectors · Physics 2015-06-18 Jiaguo Zhang , Eckhart Fretwurst , Heinz Graafsma , Robert Klanner , Ioannis Kopsalis , Joern Schwandt

Dynamic x-ray studies may reach temporal resolutions limited by only the x-ray pulse duration if the detector is fast enough to segregate synchrotron pulses. An analog integrating pixel array detector with in-pixel storage and temporal…

Instrumentation and Detectors · Physics 2010-07-28 Lucas J. Koerner , Sol M. Gruner

The European X-ray Free Electron Laser (XFEL) will deliver 27000 fully coherent, high brilliance X-ray pulses per second each with a duration below 100 fs. This will allow the recording of diffraction patterns of single molecules and the…

Instrumentation and Detectors · Physics 2015-06-03 J. Schwandt , E. Fretwurst , R. Klanner , I. Pintilie , J. Zhang

Single photon sensitivity is an important property of certain detection systems. This work investigated the single photon sensitivity of the Adaptive Gain Integrating Pixel Detector (AGIPD) and its dependence on possible detector noise…

A MHz frame rate X-ray area detector (LPD - Large Pixel Detector) is under development by the Rutherford Appleton Laboratory for the European XFEL. The detector will have 1 million pixels and allows analogue storage of 512 images taken at…

The European XFEL is an extremely brilliant Free Electron Laser Source with a very demanding pulse structure: trains of 2700 X-Ray pulses are repeated at 10 Hz. The pulses inside the train are spaced by 220 ns and each one contains up to…

We report on interferometric autocorrelation measurements of broadband supercontinuum light in the anomalous dispersion regime using two-photon absorption in a GaP photodetector. The method is simple, low-cost, and provides a direct measure…

A general theoretical approach based on the results of statistical optics is used for the analysis of the transverse coherence properties of 3-rd generation synchrotron sources and x-ray free-electron lasers (XFEL). Correlation properties…

Optics · Physics 2015-05-13 I. A. Vartanyants , A. Singer

INTPIX4NA is an integration-type silicon-on-insulator pixel detector. This detector has a 14.1 x 8.7 mm^2 sensitive area, 425,984 (832 column x 512 row matrix) pixels and the pixel size is 17 x 17 um^2. This detector was developed for…

Instrumentation and Detectors · Physics 2025-10-30 R. Nishimura , S. Kishimoto , T. Sasaki , S. Mitsui , M. Shinya , Y. Arai , T. Miyoshi

A new experimental setup combining X-Ray Photon Correlation Spectroscopy (XPCS) in the hard x-ray regime and a high-pressure sample environment is developed to monitor the pressure dependence of the internal motion of complex systems down…

Hybrid pixel single-photon-counting detectors have been successfully employed and widely used in Synchrotron radiation X-ray detection. In this paper, the silicon pixel sensors for single X-ray photon detection, which operate in…

Instrumentation and Detectors · Physics 2016-08-03 Zhen-Jie Li , Yun-Cong Jia , Ling-Fei Hu , Peng Liu , Hua-Xiang Yin

We studied spectra for 34 accretion-powered X-ray and one millisecond pulsars that were within the field of view of the INTEGRAL observatory over two years (December 2002 - January 2005) of its in-orbit operation and that were detected by…

Astrophysics · Physics 2007-05-23 E. V. Filippova , S. S. Tsygankov , A. A. Lutovinov , R. A. Sunyaev

The performance of novel n-in-p planar pixel detectors, designed for future upgrades of the ATLAS Pixel system is presented. The n-in-p silicon sensors technology is a promising candidate for the pixel upgrade thanks to its radiation…

Instrumentation and Detectors · Physics 2012-04-13 C. Gallrapp , A. La Rosa , A. Macchiolo , R. Nisius , H. Pernegger , R. H. Richter , P. Weigell

The gas pixel detector (GPD) dedicated for photoelectric X-ray polarimetry is selected as the focal plane detector for the ESA medium-class mission concept X-ray Imaging and Polarimetry Explorer (XIPE). Here we show the design, assembly,…

Instrumentation and Methods for Astrophysics · Physics 2015-12-09 H. Li , H. Feng , F. Muleri , R. Bellazzini , M. Minuti , P. Soffitta , A. Brez , G. Spandre , M. Pinchera , C. Sgro , L. Baldini , R. She , E. Costa

The Gas Pixel Detector, recently developed and continuously improved by Pisa INFN in collaboration with IASF-Roma of INAF, can visualize the tracks produced within a low Z gas by photoelectrons of few keV. By reconstructing the impact point…

Instrumentation and Methods for Astrophysics · Physics 2014-11-20 F. Muleri , R. Bellazzini , A. Brez , E. Costa , F. Lazzarotto , M. Minuti , M. Pinchera , A. Rubini , P. Soffitta , G. Spandre
‹ Prev 1 2 3 10 Next ›