Related papers: Transition Edge Sensors with Few-Mode Ballistic Th…
The state-of-the-art technology of X-ray microcalorimeters based on superconducting transition edge sensors (TESs), for applications in astrophysics and particle physics, is reviewed. We will show the advance in understanding the detector…
We have succeeded in operating a transition-edge sensor (TES) spectrometer and evaluating its performance at the SPring-8 synchrotron X-ray light source. The TES spectrometer consists of a 240 pixel National Institute of Standards and…
We present X-ray absorption spectroscopy and resonant inelastic X-ray scattering (RIXS) measurements on the iron L-edge of 0.5 mM aqueous ferricyanide. These measurements demonstrate the ability of high-throughput transition-edge-sensor…
We report the experimental evidence of the ac Josephson effect in a transition edge sensor (TES) operating in a frequency domain multiplexer and biased by ac voltage at MHz frequencies. The effect is observed by measuring the non-linear…
Arrays of hundreds or thousands of low temperature detectors have been deployed for many experiments, both bolometers for long wavelength applications and calorimeters for shorter wavelength applications. One challenge that is common to…
In order to investigate the origin of the until now unaccounted excess noise and to minimize the uncontrollable phenomena at the transition in X-ray microcalorimeters we have developed superconducting transition-edge sensors into an…
We describe the design and measurement of feedhorn-coupled, transition-edge sensor (TES) polarimeters with two passbands centered at 220 GHz and 280 GHz, intended for observations of the cosmic microwave background. Each pixel couples…
We present results on phonon quasidiffusion and Transition Edge Sensor (TES) studies in a large, 3 inch diameter, 1 inch thick [100] high purity germanium crystal, cooled to 50 mK in the vacuum of a dilution refrigerator, and exposed with…
Kinetic inductance detectors (KIDs) show promise as a competitive technology for astronomical observations over a wide range of wavelengths. We are interested in comparing the fundamental limitations to the sensitivity of KIDs with that of…
We apply noise thermometry to characterize charge and thermoelectric transport in single InAs nanowires (NWs) at a bath temperature of 4.2 K. Shot noise measurements identify elastic diffusive transport in our NWs with negligible…
The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at $\sim$10 mK, are usually…
Coherent elastic neutrino-nucleus scattering (CE$\nu$NS) offers a valuable approach in searching for physics beyond the Standard Model. The Ricochet experiment aims to perform a precision measurement of the CE$\nu$NS spectrum at the…
A photon-number resolving transition edge sensor (TES) is used to measure the photon-number distribution of two microcavity lasers. The investigated devices are bimodal microlasers with similar emission intensity and photon statistics with…
We report on efforts to improve the speed of low-G far-infrared transition-edged-sensed bolometers. We use a fabrication process that does not require any dry etch steps to reduce heat capacity on the suspended device and measure a…
Transition Edge Sensors (TESs) are characterized by the intrinsic figure of merit to resolve both the energy and the statistical distribution of the incident photons. These properties lead TES devices to become the best single photon…
We describe observations of low energy excess (LEE) events, background events observed in all light dark matter direct detection calorimeters, and noise in a Transition Edge Sensor based two-channel silicon athermal phonon detector with 375…
Experiments deploying large arrays of transition-edge sensors (TESs) often require a robust method to monitor gain variations with minimal loss of observing time. We propose a sensitive and non-intrusive method for monitoring variations in…
We briefly review a simple model of superconducting-normal phase-separation in transition-edge sensors in the SuperCDMS experiment. After discussing some design considerations relevant to the TES in the detectors, we study noise sources in…
We present a study of the energy resolution of transition-edge sensors (TESs) for the detection of electrons in the 100 eV kinetic energy range. The TES is a Ti-Au bilayer with an active area of $(60 \times 60)$ $\mu \text{m}^2$ and a…
Optical transition-edge sensors have shown energy resolution for resolving the number of incident photons at the telecommunication wavelength. Higher energy resolution is required for biological imaging and microscope spectroscopy. In this…