English
Related papers

Related papers: Development of large-area quadrant silicon detecto…

200 papers

The past ten years have seen the advent of silicon-based precise timing detectors for charged particle tracking. The underlying reason for this evolution is a design innovation: the Low-Gain Avalanche Diode (LGAD). In its simplicity, the…

High Energy Physics - Experiment · Physics 2022-08-31 N. Cartiglia , R. Arcidiacono , M. Costa , M. Ferrero , G. Gioachin , M. Mandurrino , L. Menzio , F. Siviero , V. Sola , M. Tornago

A monolithic silicon pixel prototype produced for the MONOLITH ERC Advanced project was irradiated with 70 MeV protons up to a fluence of 1 x 10^16 1 MeV n_eq/cm^2. The ASIC contains a matrix of hexagonal pixels with 100 {\mu}m pitch,…

We report on multilayer high efficiency antireflection coating (ARC) design and development for use at UV wavelengths on CCDs and other Si-based detectors. We have previously demonstrated a set of single-layer coatings, which achieve >50%…

Large mass single-electron-resolution solid state detectors are desirable to search for low mass dark matter candidates and to measure coherent elastic neutrino nucleus scattering (CE$\nu$NS). Here, we present results from a novel 100 g…

Instrumentation and Detectors · Physics 2021-08-04 V. Iyer , N. Mirabolfathi , G. Agnolet , H. Chen , A. Jastram , F. Kadribasic , V. K. S. Kashyap , A. Kubik , M. Lee , R. Mahapatra , B. Mohanty , H. Neog , M. Platt

Semiconductor quantum photonic circuits can be used to efficiently generate, manipulate, route and exploit non-classical states of light for distributed photon based quantum information technologies. In this article, we review our recent…

Mesoscale and Nanoscale Physics · Physics 2016-07-01 Michael Kaniber , Fabian Flassig , Günther Reithmaier , Rudolf Gross , Jonathan J. Finley

The CMS silicon tracker consists of two tracking devices utilizing semiconductor technology: the inner pixel and the outer strip detectors. They operate in a high-occupancy and high-radiation environment presented by particle collisions in…

Instrumentation and Detectors · Physics 2019-08-13 Viktor Veszpremi

We study quantum coherence in a semiconductor charge qubit formed from a GaAs double quantum dot containing a single electron. Voltage pulses are applied to depletion gates to drive qubit rotations and non-invasive state readout is achieved…

Mesoscale and Nanoscale Physics · Physics 2013-05-29 K. D. Petersson , J. R. Petta , H. Lu , A. C. Gossard

CLIC is a proposed linear e+e- collider designed to provide particle collisions at center-of-mass energies of up to 3 TeV. Precise measurements of the properties of the top quark and the Higgs boson, as well as searches for Beyond the…

Instrumentation and Detectors · Physics 2017-06-21 Simon Spannagel

Silicon carbide (SiC) particle detectors have the potential to provide time resolutions and robust performance in extreme environments which exceed that of silicon detectors. In this work 4H-SiC low gain avalanche detectors (LGADs) and…

A solid-state quantum computer with dipolar coupling between qubits is proposed. The qubits are formed by the low-lying states of an isolated acceptor in silicon. The system has the scalability inherent to spin-based solid state systems,…

Mesoscale and Nanoscale Physics · Physics 2007-05-23 B. Golding , M. I. Dykman

We report high-bandwidth charge sensing measurements using a GaAs quantum point contact embedded in a radio frequency impedance matching circuit (rf-QPC). With the rf-QPC biased near pinch-off where it is most sensitive to charge, we…

Mesoscale and Nanoscale Physics · Physics 2009-11-13 D. J. Reilly , C. M. Marcus , M. P. Hanson , A. C. Gossard

An x-ray detector using a liquid-helium cooled large-area silicon PIN photodiode has been developed along with a tailor-made charge sensitive preamplifier whose first-stage JFET has been cooled. The operating temperature of the JFET has…

High Energy Physics - Experiment · Physics 2009-10-28 Yoshizumi Inoue , Shigetaka Moriyama , Hideyuki Hara , Makoto Minowa , Fumio Shimokoshi

The next generation of very-short-baseline reactor experiments will require compact detectors operating at surface level and close to a nuclear reactor. This paper presents a new detector concept based on a composite solid scintillator…

A detailed and accurate characterisation of silicon photomultiplier detectors is required for a better understanding of the signal and noise in many applications. The collected information is a valuable feedback to the manufacturers in…

Instrumentation and Detectors · Physics 2018-08-20 Olivier Girard , Guido Haefeli , Axel Kuonen , Luca Pescatore , Olivier Schneider , Maria Elena Stramaglia

Extremely radiation hard sensors are needed in particle physics experiments to instrument the region near the beam pipe. Examples are beam halo and beam loss monitors at the Large Hadron Collider, FLASH or XFEL. Currently artificial diamond…

Instrumentation and Detectors · Physics 2015-09-02 O. Karacheban , K. Afanaciev , M. Hempel , H. Henschel , W. Lange , J. L. Leonard , I. Levy , W. Lohmann , S. Schuwalow

To face the higher levels of radiation due to the 10-fold increase in integrated luminosity during the High-Luminosity LHC, the CMS detector will replace the current Calorimeter Endcap (CE) using the High-Granularity Calorimeter (HGCAL)…

The Large High Altitude Air Shower Observatory (LHAASO) project has been proposed for the survey and study of cosmic rays. In the LHAASO project, the Water Cherenkov Detector Array (WCDA) is one of major detectors for searching gamma ray…

Instrumentation and Detectors · Physics 2016-01-20 Weihao Wu , Lei Zhao , Yu Liang , Li Yu , Jianfeng Liu , Shubin Liu , Qi An

Hybrid silicon pixel detectors are currently used in the innermost tracking system of the Compact Muon Solenoid (CMS) experiment. Radiation tolerance up to fluences expected for a few years of running of the Large Hadron Collider (LHC) has…

Instrumentation and Detectors · Physics 2011-10-07 Gemma Tinti

For a long time, scintillator detectors have suffered from relatively weak spatial resolution due to various influencing factors. Additionally, the high cost of photomultiplier tubes (PMTs) has limited the widespread adoption of…

Instrumentation and Detectors · Physics 2025-04-29 S. K. Lv , C. S. Dai , D. D. Hu , T. C. Zhong , W. F. Wu , X. J. Wang

We report on a large active area (15x15mm2), high channel density (470 pixels/mm2), self-triggering CMOS analog chip that we have developed as pixelized charge collecting electrode of a Micropattern Gas Detector. This device, which…

‹ Prev 1 4 5 6 7 8 10 Next ›