Related papers: An Efficient monochromatic Electron Source designe…
Compact coherent x-ray sources have been the focus of extensive research efforts over the past decades. As a result, several novel schemes like optical and nano-undulators for generating x-ray emissions in "table-top" setups are proposed,…
Using a model methane-like chiral system, we theoretically demonstrate a possibility to access photoelectron circular dichroism (PECD) by a single experiment with two overlapping laser pulses of carrier frequencies $\omega$ and $2\omega$,…
The SPectrometer for Internal Conversion Electrons (SPICE) has been commissioned for use in conjunction with the TIGRESS $\gamma$-ray spectrometer at TRIUMF's ISAC-II facility. SPICE features a permanent rare-earth magnetic lens to collect…
Numerous applications of M\"{o}ssbauer spectroscopy are related to a unique resolution of absorption spectra of resonant radiation in crystals, when the nucleus absorbs a photon without a recoil. However, the narrow nuclear linewidth…
It is known, that at high energies of ions (more than 10 MeV for light ions) the focusing by magnetic quadrupole fields is most effective, whereas at small energies (less than 1 MeV) - the focusing by electrical quadrupole fields. At…
The determination of the neutrino mass is an open issue in modern particle physics and astrophysics. The direct mass measurement is the only theory-unrelated experimental tool capable to probe such quantity. The HOLMES experiment aims to…
We report the design of an angular array of electron Time-of-Flight (eToF) spectrometers intended for non-invasive spectral, temporal, and polarization characterization of single shots of high-repetition rate, quasi-continuous,…
The strong electric field between the sample and the extractor is the core of cathode lenses and a pivotal determinant of high resolution. Nevertheless, fields in the range of 3-8 kV/mm can be a source of complications. Local field…
We report on the detection of single photons with {\lambda} = 8 {\mu}m using a superconducting hot-electron microbolometer. The sensing element is a titanium transition-edge sensor with a volume ~ 0.1 {\mu}m^3 fabricated on a silicon…
Aberration-corrected scanning transmission electron microscopes (STEM) provide sub-angstrom lateral resolution; however, the large convergence angle greatly reduces the depth of field. For microscopes with a small depth of field,…
Ultrafast transmission electron microscopy (UTEM) has emerged as a versatile technique for the time-resolved imaging of nanoscale dynamics on timescales down to few-hundred attoseconds but the temporal and spatial resolutions are still…
Inverse Compton scattering (ICS) is a unique source of highly monochromatic x-ray and gamma radiation. We investigate theoretically the cumulative effects of repeated interactions between the electron beam and a train of powerful laser…
A high-resolution beam telescope is essential for the precise characterization of silicon pixel sensors. As part of the CSNS-II upgrade project, a High-Energy Proton Beam Telescope (HEPTel) based on monolithic active pixel sensors (MAPS)…
Secondary electron (SE) imaging techniques, such as scanning electron microscopy and helium ion microscopy (HIM), use electrons emitted by a sample in response to a focused beam of charged particles incident at a grid of raster scan…
Ultrafast electron pulses, combined with laser-pump and electron-probe technologies, allow for various forms of ultrafast microscopy and spectroscopy to elucidate otherwise challenging to observe physical and chemical transitions. However,…
Electrical impedance tomography with fully integrated microfluidics and electronics is presented for the first time in a CMOS chip. Chambers and electrodes are fabricated in the interconnect layers of a 65 nm CMOS chip through…
The 511 keV electron-positron annihilation feature near the galactic center has been detected for more than half a century, yet its origin remains a mystery. In this paper, we describe a concept for a balloon-borne 511 keV $\gamma$-ray…
We discuss a high-energy photon linear collider (HE PLC) based on the $e^+e^-$ linear collider with cms electron energy $2E = 1 \div 2$ TeV (JLC, CLIC,...). This energy region was previously considered hopeless for experiment. On the…
$\beta$-Ga$_{2}$O$_{3}$ nanomembranes, obtained by ion-beam-assisted exfoliation, are used in the fabrication of simple metal-semiconductor-metal (MSM) structures, that are tested as photodetectors (PD) and field-effect transistors (FET).…
Electrochemical Impedance Spectroscopy (EIS) is a crucial technique for assessing corrosion of a metallic materials. The analysis of EIS hinges on the selection of an appropriate equivalent circuit model (ECM) that accurately characterizes…