English
Related papers

Related papers: Optical Readout of a Two Phase Liquid Argon TPC us…

200 papers

The ATLAS phase-I upgrade aims to enhance event trigger performance in the Liquid Argon (LAr) calorimeter and the forward muon spectrometer. The trigger signals are transmitted by optical transceivers at 5.12 Gbps per channel in a radiation…

Instrumentation and Detectors · Physics 2020-10-28 L. Zhang , C. Chen , I. Cohen , E. Cruda , D. Gong , S. Hou , X. Hu , X. Huang , J. -H. Li , C. Liu , T. Liu , L. Murphy , T. Schwarz , H. Sun , X. Sun , J. Thomas , Z. Wang , J. Ye , W. Zhang

Dual phase Xenon Time Projection Chambers (XeTPCs) are being used by several experiments as a promising technique for direct detection of dark matter. We report on the design and performance of a small 3-D sensitive dual phase XeTPC. The…

Instrumentation and Detectors · Physics 2015-06-17 Qing Lin , Yuehuan Wei , Jie Bao , Jie Hu , Xinran Li , Wolfgang Lorenzon , Kaixuan Ni , Michael Schubnell , Mengjiao Xiao , Xiang Xiao

We report the performance of a 10 atm Xenon/trimethylamine time projection chamber (TPC) for the detection of X-rays (30 keV) and gamma-rays (0.511-1.275 MeV) in conjunction with the accurate tracking of the associated electrons. When…

A new type of the Multi-Pixel Photon Counter (MPPC), sensitive to Vacuum Ultra-Violet (VUV) light (wavelength {\lambda} < 150 nm), is recently developed and produced by Hamamatsu Photonics K.K. The basic properties of the new MPPC are…

Instrumentation and Detectors · Physics 2016-08-24 T. Igarashi , S. Naka , M. Tanaka , T. Washimi , K. Yorita

The use of gaseous Time Projection Chambers enables the detection and the detailed study of rare events due to particles interactions with the atoms of the gas with energy releases as low as a few keV. Due to this capability, these…

The world's leading directional dark matter experiments currently all utilize low-pressure gas Time Projection Chamber (TPC) technologies. We discuss some of the challenges for this technology, for which balancing the goal of achieving the…

Instrumentation and Detectors · Physics 2024-07-19 N. S. Phan , R. J. Lauer , E. R. Lee , D. Loomba , J. A. J. Matthews , E. H. Miller

We present spectroscopic measurements of xenon luminescence in a time projection chamber operated in a dual-phase (liquid-gas) configuration. Thorium-228 $\alpha$ decays excited the liquid, resulting in the formation of singlet and triplet…

Instrumentation and Detectors · Physics 2025-12-25 K. C. Oliver-Mallory , A. M. Baker , E. Jacquet , T. J. Sumner , H. M. Araujo

A successful operation of a new optical readout system (THGEM + WLS + MGPDs (multichannel array of multipixel avalanche Geiger photodiodes) in a two-phase liquid xenon detector was demonstrated.

Micro-TPC, a time projection chamber(TPC) with micro pixel chamber($\mu$-PIC) readout was developed for the detection of the three-dimensional fine(sub-m illimeter) tracks of charged particles. We developed a two-dimensional position…

High Energy Physics - Experiment · Physics 2009-11-10 Kentaro Miuchi , Hidetoshi Kubo , Tsutomu Nagayoshi , Atsuhiko Ochi , Reiko Orito , Atsushi Takada , Toru Tanimori , Masaru Ueno

The novel SoLAr concept aims to extend sensitivities of liquid-argon neutrino detectors down to the MeV scale for next-generation detectors. SoLAr plans to accomplish this with a liquid-argon time projection chamber that employs an anode…

Silicon photomultiplier (SiPM), a new type of photosensor, is considered a substitute for traditional photomultiplier tube (PMT) in the next generation of dark matter and neutrino detectors, especially in noble gas detectors like liquid…

Instrumentation and Detectors · Physics 2023-05-31 T. A. Wang , C. Guo , X. H. Liang , L. Wang , M. Y. Guan , C. G. Yang , J. C. Liu , F. Y. Lin

Dual-phase time projection chambers (TPCs) filled with the liquid noble gas xenon (LXe) are currently the most sensitive detectors searching for interactions of WIMP dark matter in a laboratory-based experiment. This is achieved by…

Instrumentation and Methods for Astrophysics · Physics 2014-08-08 Marc Schumann

High pressure xenon Time Projection Chambers (TPC) based on secondary scintillation (electroluminescence) signal amplification are being proposed for rare event detection such as directional dark matter, double electron capture and double…

Detectors based on liquid argon (LAr) often require surfaces that can shift vacuum ultraviolet (VUV) light and reflect the visible shifted light. For the LAr instrumentation of the LEGEND-200 neutrinoless double beta decay experiment,…

Instrumentation and Detectors · Physics 2022-05-17 G. R. Araujo , L. Baudis , N. McFadden , P. Krause , S. Schönert , V. H. S. Wu

One of the main features of two-phase detectors with electroluminescence (EL) gap being developed in our laboratory for dark matter search is the extensive use of THGEMs (Thick Gas Electron Multipliers). In various versions of the detector,…

Instrumentation and Detectors · Physics 2019-09-04 Alexander Bondar , Alexei Buzulutskov , Egor Frolov , Vladislav Oleynikov , Ekaterina Shemyakina , Andrey Sokolov

The Liquid Argon Time Projection Chambers (LArTPCs) are a choice for the next generation of large neutrino detectors due to their optimal performance in particle tracking and calorimetry. The detection of Argon scintillation light plays a…

Instrumentation and Detectors · Physics 2018-04-18 G. Cancelo , F. Cavanna , C. O. Escobar , E. Kemp , A. A. Machado , A. Para , E. Segreto , D. Totani , D. Warner

The purpose of this project is to investigate the use of charge couple devices (CCDs) to detect electrons directly. This can be done in transmission electron microscopy (TEM) for electrons over 100 KeV, but for space plasma instruments,…

Instrumentation and Detectors · Physics 2015-10-28 S. R. Mirfayzi

A sealed high gas pressure detector working in pure argon is assembled. It consists of a 5 cm $\times$ 5 cm PCB THGEM (THick Gaseous Electron Multipliers). The detector structure and experimental setup are described. The performances under…

Instrumentation and Detectors · Physics 2016-12-26 Yu-Ning Zhang , Qian Liu , Hong-Bang Liu , Yi-Gang Xie , Xiao-Rui Lyu , Shi Chen , Wen-Qian Huang , Dao-Jin Hong , Yang-Heng Zheng

We report on a measurement of the absorption length of scintillation light in liquid argon due to dissolved nitrogen at the part-per-million (ppm) level. We inject controlled quantities of nitrogen into a high purity volume of liquid argon…

Instrumentation and Detectors · Physics 2015-06-16 B. J. P. Jones , C. S. Chiu , J. M. Conrad , C. M. Ignarra , T. Katori , M. Toups