English
Related papers

Related papers: Optical Readout of a Two Phase Liquid Argon TPC us…

200 papers

We report on the construction, tests, calibrations and commissioning of an Optical Readout Time Projection Chamber (O-TPC) detector operating with a CO2(80%) + N2(20%) gas mixture at 100 and 150 Torr. It was designed to measure the cross…

Systematic uncertainties in accelerator oscillation neutrino experiments arise mostly from nuclear models describing neutrino-nucleus interactions. To mitigate these uncertainties, we can study neutrino-nuclei interactions with detectors…

Instrumentation and Detectors · Physics 2023-10-31 R. M Amarinei , F. Sánchez , E. Roe , S. Bordoni , L. Giannessi , T Lux , E. Radicioni

Operation results are presented of a UV-sensitive gaseous photomultiplier (GPM) coupled through a MgF2 window to a liquid-xenon scintillator. It consisted of a reflective CsI photocathode deposited on top of a THick Gaseous Electron…

We successfully operated a novel kind of LAr Time Projection Chamber based on a Large Electron Multiplier (LEM) readout system. The prototype, of about 3 liters active volume, is operated in liquid-vapour (double) phase pure Ar. The…

Instrumentation and Detectors · Physics 2008-11-21 A. Badertscher , L. Knecht , M. Laffranchi , A. Marchionni , G. Natterer , P. Otiougova , F. Resnati , A. Rubbia

Scintillation properties of the new Tl2LaCl5: xCe3+ where x = 0, 0.5, 1 and 10 mole % (TLC: Ce3+) single crystals are presented. Two zones vertical Bridgman technique is used for the growth of this scintillation material. High Z-number (79)…

Materials Science · Physics 2017-04-05 H. J. Kim , Gul Rooh , Sunghwan Kim

In this work we discuss the mechanism behind the large electroluminescence signals observed at relatively low electric fields in the holes of a Thick Gas Electron Multiplier (THGEM) electrode immersed in liquid xenon. We present strong…

Instrumentation and Detectors · Physics 2015-09-30 L. Arazi , E. Erdal , A. E. C. Coimbra , M. L. Rappaport , D. Vartsky , V. Chepel , A. Breskin

The detection of VUV scintillation light, e.g. in (liquid) argon detectors, commonly includes a reflector with a fluorescent coating, converting UV photons to visible light. The light yield of these detectors depends directly on the…

Instrumentation and Detectors · Physics 2015-12-16 Laura Baudis , Giovanni Benato , Rugard Dressler , Francesco Piastra , Ilya Usoltsev , Manuel Walter

We studied electron amplification and light emission from avalanches in oxygen-containing gas mixtures. The mixtures investigated in this work included, among others, CO2 and N2O mixed with Triethylamine (TEA) or N2. Double-Step Parallel…

Instrumentation and Detectors · Physics 2008-11-26 L. Weissman , M. Gai , A. Breskin , R. Chechik , V. Dangendorf , K. Tittelmeier , H. R. Weller

We present the operation of the recently introduced Photon Assisted Cascaded Electron Multiplier (PACEM) in xenon at high pressure. The PACEM is a multi step electron multiplier where the VUV scintillation produced in the electron…

Instrumentation and Detectors · Physics 2009-06-25 F. D. Amaro , J. F. C. A. Veloso , J. M. F. dos Santos , A. Breskin , R. Chechik , A. Lyashenko

The measurement of the 2D-Angular Correlation of Electron Positron Annihilation Radiation (ACAR) provides unique information about the bulk electronic structure of single crystals. We set up a new prototype for 2D-ACAR measurements using…

Instrumentation and Detectors · Physics 2024-12-23 Kilian Brenner , Francesco Guatieri , Christoph Hugenschmidt

The DarkSide-50 experiment at the Laboratori Nazionali del Gran Sasso is a search for dark matter using a dual phase time projection chamber with 50 kg of low radioactivity argon as target. Light signals from interactions in the argon are…

Instrumentation and Detectors · Physics 2018-01-17 DarkSide Collaboration , P. Agnes , I. F. M. Albuquerque , T. Alexander , A. K. Alton , K. Arisaka , D. M. Asner , M. Ave , H. O. Back , B. Baldin , K. Biery , V. Bocci , G. Bonfini , W. Bonivento , M. Bossa , B. Bottino , A. Brigatti , J. Brodsky , F. Budano , S. Bussino , M. Cadeddu , M. Cadoni , F. Calaprice , N. Canci , A. Candela , H. Cao , M. Caravati , M. Cariello , M. Carlini , S. Catalanotti , V. Cataudella , P. Cavalcante , A. Chepurnov , C. Cicaló , A. G. Cocco , G. Covone , L. Crippa , D. D'Angelo , M. D'Incecco , S. Davini , A. deCandia , S. DeCecco , M. DeDeo , G. DeFilippis , G. DeRosa , M. DeVincenzi , A. Derbin , A. Devoto , F. DiEusanio , C. Dionisi , G. DiPietro , E. Edkins , A. Empl , A. Fan , G. Fiorillo , K. Fomenko , G. Forster , D. Franco , F. Gabriele , C. Galbiat , S. Giagu , C. Giganti , G. K. Giovanetti , A. M. Goretti , F. Granato , L. Grandi , M. Gromov , M. Guan , Y. Guardincerri , B. R. Hackett , K. R. Herner , D. Hughes , P. Humble , E. V. Hungerford , Aldo Ianni , Andrea Ianni , I. James , T. N. Johnson , K. Keeter , C. L. Kendziora , V. Kobychev , G. Koh , D. Korablev , G. Korga , A. Kubankin , X. Li , M. Lissia , B. Loer , P. Lombardi , G. Longo , S. Luitz , Y. Ma , A. Machado , I. N. Machulin , A. Mandarano , S. M. Mari , J. Maricic , L. Marini , C. J. Martoff , P. D. Meyers , T. Miletic , R. Milincic , D. Montanari , A. Monte , M. Montuschi , M. E. Monzani , P. Mosteiro , B. J. Mount , V. N. Muratova , P. Musico , A. NavrerAgasson , A. Nelson , S. Odrowsk , A. Oleinik , M. Orsini , F. Ortica , L. Pagani , M. Pallavicini , E. Pantic , S. Parmeggiano , K. Pelczar , N. Pelliccia , A. Pocar , S. Pordes , D. A. Pugachev , H. Qian , K. Randle , G. Ranucci , M. Razeti , A. Razeto , B. Reinhold , A. L. Renshaw , M. Rescigno , Q. Riffard , A. Romani , B. Rossi , N. Rossi , S. D. Rountree , D. Sablone , P. Saggese , R. Saldanha , W. Sands , S. Sangiorgio , C. Savarese , B. Schlitzer , E. Segreto , D. A. Semenov , E. Shields , P. N. Singh , M. D. Skorokhvatov , O. Smirno , A. Sotnikov , C. Stanford , Y. Suvorov , R. Tartaglia , J. Tatarowicz , G. Testera , A. Tonazzo , P. Trinchese , E. V. Unzhakov , M. Verducci , A. Vishneva , R. B. Vogelaar , M. Wada , S. Walker , H. Wang , Y. Wang , A. W. Watson , S. Westerdale , M. M. Wojcik , X. Xiang , X. Xiao , J. Xu , C. Yang , J. Yoo , S. Zavatarelli , A. Zec , W. Zhong , C. Zhu , G. Zuzel

ICARUS T600 will be operated as far detector of the Short Baseline Neutrino program at Fermilab (USA), which foresees three liquid argon time projection chambers along the Booster Neutrino Beam line to search for a LSND-like sterile…

We have built and operated a crystalline/vapor xenon TPC, with the goal of improving searches for dark matter. The motivation for this instrument is the fact that beta decays from the radon decay chain to the ground state presently limit…

Instrumentation and Detectors · Physics 2022-05-04 S. Kravitz , H. Chen , R. Gibbons , S. J. Haselschwardt , Q. Xia , P. Sorensen

This paper evaluates the radiation tolerance of commercial off-the-shelf (COTS) electronics components for use in the Thin Gap Chamber (TGC) frontend electronics of the ATLAS experiment at the High-Luminosity LHC (HL-LHC). The ATLAS…

The MicroBooNE detector, to be located on axis in the Booster Neutrino Beamline (BNB) at the Fermi National Accelerator Laboratory (Fermilab), consists of two main components: a large liquid argon time projection chamber (LArTPC), and a…

Several experiments have been conducted worldwide, with the goal of observing low-energy nuclear recoils induced by WIMPs scattering off target nuclei in ultra-sensitive, low-background detectors. In the last few decades noble liquid…

Instrumentation and Detectors · Physics 2016-03-23 B. Rossi , A. Anastasio , A. Boiano , S. Catalanotti , A. G. Cocco , G. Covone , P. Di Meo , G. Longo , A. Vanzanella , S. Walker , H. Wang , Y. Wang , G. Fiorillo

ProtoDUNE-DP is a 6x6x6 m3 liquid argon time-projection-chamber (LArTPC) operated at the Neutrino Platform at CERN in 2019-2020 as a prototype of the DUNE Far Detector. DUNE is a dual-site experiment for long-baseline neutrino oscillation…

Instrumentation and Detectors · Physics 2022-12-21 C. Cuesta

Liquid argon is used as a target material in several current and planned experiments related to dark matter direct searching and neutrino detection. SiPM is becoming the standard for scintillator detectors because of its advantages over…

Instrumentation and Detectors · Physics 2023-01-03 L. Wang , Y. Lei , T. A. Wang , C. Guo , K. K. Zhao , X. H. Liang , S. B. Wang , Y. D. Chen

The characteristic properties of two-phase Ar avalanche detectors, including those obtained with CsI photocathode, are further studied. Such detectors are relevant in the field of coherent neutrino-nucleus scattering and dark matter search…

Instrumentation and Detectors · Physics 2008-12-18 A. Bondar , A. Buzulutskov , A. Grebenuk , D. Pavlyuchenko , Y. Tikhonov

At present, a two-phase argon detector is being developed in our laboratory for dark matter search and low-energy neutrino experiments. To calibrate its energy scale a $^{109}$Cd gamma-ray source was used. In this work a detailed emission…

Instrumentation and Detectors · Physics 2018-06-01 A. Bondar , A. Buzulutskov , A. Dolgov , A. Legkodymov , V. Nosov , V. Oleynikov , V. Porosev , E. Shemyakina , A. Sokolov
‹ Prev 1 3 4 5 6 7 10 Next ›