Related papers: CDF Run II Silicon Vertex Detector Annealing Study
The Collider Detector at Fermilab (CDF) pursues a broad physics program at Fermilab's Tevatron collider. Between Run II commissioning in early 2001 and the end of operations in September 2011, the Tevatron delivered 12 fb-1 of integrated…
The CDF Run II silicon detector is the largest operating detector of its kind in High Energy Physics, collecting p-pbar collision data at the Fermilab Tevatron since 2001. It provides precision tracking and vertexing which played a critical…
Several thin Low Gain Avalanche Detectors from Hamamatsu Photonics were irradiated with neutrons to different equivalent fluences up to $\Phi_{eq}=3\cdot10^{15}$ cm$^{-2}$. After the irradiation they were annealed at 60$^\circ$C in steps to…
Thin pad detectors made from 75 $\mu$m thick epitaxial silicon on low resistivity substrate were irradiated with reactor neutrons to fluences from 2.5$\times 10^{16}$ n/cm$^2$ to 1$\times 10^{17}$ n/cm$^2$. Edge-TCT measurements showed that…
After a five year upgrade period, the CDF detector located at the Fermilab Tevatron Collider is back in operation taking high quality data with all subsystems functional. We report on the status of the CDF experiment in Run II and discuss…
A next generation silicon vertex detector is planned at CDF for the 1998 Tevatron collider run with the Main Injector. The SVX~II silicon vertex detector will allow high luminosity data-taking, enable online triggering of secondary vertex…
Run II at the Tevatron Collider started at the beginning of March 2001. With extensive upgrades on both detectors and electronics the CDF II began to collect data. This paper reviews early Run II physics results obtained by analyzing data…
The Collider Detector at Fermilab (CDF) records proton-antiproton collisions at center of mass energy of 2.0 TeV at the Tevatron collider. A new collider run, Run II, of the Tevatron started in April 2001. Increased luminosity will result…
The Online Silicon Vertex Tracker is the new CDF-II level 2 trigger processor designed to reconstruct 2-D tracks within the Silicon Vertex Detector with high speed and accuracy. By performing a precise measurement of impact parameters the…
The silicon strip sensors of the Belle II silicon vertex detector were irradiated with 90 MeV electron beams up to an equivalent 1-MeV-neutron fluence of $3.0\times 10^{13}~{\rm n}_{\rm eq}/{\rm cm^2}$. We measure changes in sensor…
A measurement has been made of the radiation damage incurred by the ATLAS Pixel Detector barrel silicon modules from the beginning of operations through the end of 2012. This translates to hadronic fluence received over the full period of…
The high-luminosity upgrade of the CERN LHC requires the replacement of the CMS tracking detector to cope with the increased radiation fluence while maintaining its excellent performance. An extensive R\&D program, aiming at using 3D pixel…
The performance of the D0 experiment forward muon scintillation counters system during Run II of the Tevatron from 2001 to 2011 is described. The system consists of 4214 scintillation counters in six layers. The long term stability of the…
The 1992-1995 running of the Fermilab Tevatron ended with many important physics goals accomplished, including the discovery of the top quark, and the anticipation of many further questions to be answered in the future. After many upgrades…
To face the higher levels of radiation due to the 10-fold increase in integrated luminosity during the High-Luminosity LHC, the CMS detector will replace the current Calorimeter Endcap (CE) using the High-Granularity Calorimeter (HGCAL)…
Non-ionizing energy loss causes bulk damage to the silicon sensors of the ATLAS pixel and strip detectors. This damage has important implications for data-taking operations, charged-particle track reconstruction, detector simulations, and…
We present measurements of the top-antitop production cross section in b-tagged lepton + jets events from proton-antiproton collisions at 1.96 TeV using the CDF detector at Fermilab. B-jets are tagged with either a secondary vertex…
Silicon detection is a mature technology for registering the passage of charged particles. At the same time it continues to evolve toward increasing radiation tolerance as well as precision and adaptability. For these reasons it is likely…
The CDF experiment's Silicon Vertex Trigger is a system of 150 custom 9U VME boards that reconstructs axial tracks in the CDF silicon strip detector in a 15 microsecond pipeline. SVT's 35 micron impact parameter resolution enables CDF's…
This paper describes the performance of a prototype timing detector, based on 50 micrometer thick Ultra Fast Silicon Detector, as measured in a beam test using a 180 GeV/c momentum pion beam. The dependence of the time precision on the…