English
Related papers

Related papers: Atomic resolution STM in a cryogen free dilution r…

200 papers

We report the design and performance of a cryogen-free, pulse-tube refrigerator (PTR)-based scanning probe microscopy (SPM) system capable of operating at the base temperature of near 5K. We achieve this by combining a home-made interface…

Materials Science · Physics 2022-04-29 Jun Kasai , Tomoki Koyama , Munenori Yokota , Katsuya Iwaya

We present a probe-type scanning tunneling microscope (STM) with atomic resolution that is designed to be directly inserted and work in a harsh vibrational cryogen-free superconducting magnet system. When a commercial variable temperature…

Instrumentation and Detectors · Physics 2018-06-01 Wenjie Meng , Jihao Wang , Yubin Hou , Mengqiao Sui , Junting Wang , Gang Wu , Junyun Li , Qingyou Lu

Low-temperature scanning probe microscopes (SPMs) are critical for the study of quantum materials and quantum information science. Due to the rising costs of helium, cryogen-free cryostats have become increasingly desirable. However, they…

We report on our design of a scanning gate microscope housed in a cryogen-free dilution refrigerator with a base temperature of 15 mK. The recent increase in efficiency of pulse tube cryocoolers has made cryogen-free systems popular in…

Instrumentation and Detectors · Physics 2014-09-09 Matthew Pelliccione , Adam Sciambi , John Bartel , Andrew Keller , David Goldhaber-Gordon

One of the daunting challenges in modern low temperature scanning tunneling microscopy (STM) is the difficulty of combining atomic resolution with cryogen free cooling. Further functionality needs, such as ultra-high vacuum (UHV), high…

Mesoscale and Nanoscale Physics · Physics 2024-04-09 Angela M. Coe , Guohong Li , Eva Y. Andrei

We have designed and built a scanning tunneling microscope (STM) setup for operation at millikelvin temperatures in ultra high vacuum. A compact cryostat with an integrated dilution refrigerator has been built, that allows measurements at a…

Instrumentation and Detectors · Physics 2018-12-05 Timofey Balashov , Michael Meyer , Wulf Wulfhekel

We describe the construction and performance of a scanning tunneling microscope (STM) capable of taking maps of the tunneling density of states with sub-atomic spatial resolution at dilution refrigerator temperatures and high (14 T)…

Instrumentation and Detectors · Physics 2013-10-04 Shashank Misra , Brian B. Zhou , Ilya K. Drozdov , Jungpil Seo , Andras Gyenis , Simon C. J. Kingsley , Howard Jones , Ali Yazdani

Ultra-low temperature scanning tunnelling microscopy and spectroscopy (STM/STS) achieved by dilution refrigeration can provide unrivalled insight into the local electronic structure of quantum materials and atomic-scale quantum systems.…

We report the achievement of the first atomically resolved scanning tunneling microscope (STM) imaging in a water-cooled magnet (WM), where the extremely harsh vibrations and noises have been the major challenge. This homebuilt WM-STM…

Mesoscale and Nanoscale Physics · Physics 2015-05-15 Wenjie Meng , Ying Guo , Yubin Hou , Qingyou Lu

This article presents an evaluation of off-the-shelf commercial accelerometers at the mixing chamber stage of a cryogen-free dilution refrigerator at temperatures down to 8 mK. In addition, we present results of radioassay of accelerometer…

Pulse-tube based dilution refrigerators are massively employed in low temperature physics. They allow to reduce the running costs and to be operated with unprecedented easiness. However, the main drawback of this technology is the…

Instrumentation and Detectors · Physics 2018-09-05 R. Maisonobe , J. Billard , M. De Jesus , A. Juillard , D. Misiak , E. Olivieri , S. Sayah , L. Vagneron

We describe a compact ultra-high vacuum (UHV) scanning tunneling microscope (STM) system that does not need any external supply of cooling liquids. It achieves temperatures down to 1.5 K and a z-noise down to 300 fmRMS for the frequency…

We present the design and operation of a very-low temperature Scanning Tunneling Microscope (STM) working at $60 mK$ in a dilution refrigerator. The STM features both atomic resolution and micron-sized scanning range at low temperature.…

Mesoscale and Nanoscale Physics · Physics 2009-10-31 N. Moussy , H. Courtois , B. Pannetier

The spectroscopic resolution of tunneling measurements performed with a scanning tunneling microscope is ultimately limited by the temperature at which the experiment is performed. To take advantage of the potential high spectroscopic…

Instrumentation and Detectors · Physics 2007-05-23 H. Le Sueur , P. Joyez

Atomic resolution imaging is demonstrated using a hybrid scanning tunneling/near-field microwave microscope (microwave-STM). The microwave channels of the microscope correspond to the resonant frequency and quality factor of a coaxial…

Mesoscale and Nanoscale Physics · Physics 2011-08-16 Jonghee Lee , Christian J. Long , Haitao Yang , Xiao-Dong Xiang , Ichiro Takeuchi

We present the design and implementation of a mechanical low-pass filter vibration isolation used to reduce the vibrational noise in a cryogen-free dilution refrigerator operated at 10 mK, intended for scanning probe techniques. We discuss…

We describe the design and performance of a scanning tunneling microscope (STM) which operates at a base temperature of 30 mK in a vector magnetic field. The cryogenics is based on an ultra-high vacuum (UHV) top-loading wet dilution…

A spectroscopic imaging-scanning tunneling microscope (SI-STM) allows the atomic scale visualization of surface electronic and magnetic structure of novel quantum materials with high energy resolution. To achieve the optimal performance,…

We describe a fully ultra-high vacuum compatible scanning tunneling microscope (STM) optimized for radio-frequency signals. It includes in-situ exchangeable tips adapted to high frequency cabling and a standard sample holder, which offer…

Mesoscale and Nanoscale Physics · Physics 2013-02-27 Christian Saunus , Jan Raphael Bindel , Marco Pratzer , Markus Morgenstern
‹ Prev 1 2 3 10 Next ›