Related papers: Property of LCP-GEM in Pure Dimethyl Ether at Low …
We have produced thick-foil and fine-pitch gas electron multipliers (GEMs) using a laser etching technique. To improve production yield we have employed a new material, Liquid Crystal Polymer, instead of polyimide as an insulator layer. The…
GEM are widely used as amplification stages in gaseous detectors exposed to high rates. The GEM consists of a polyimide foil which is coated by two thin copper layers. Charges collected into the holes or created during the amplification…
The High Energy Physics group of the University of Texas at Arlington Physics Department has been developing Gas Electron Multiplier (GEM) detectors for use as the sensitive gap detector in digital hadron calorimeters (DHCAL) for the future…
The properties of thick GEM-like (TGEM) gaseous electron multipliers, operated at 1-740 Torr are presented. They are made of a G-10 plate, perforated with millimeter-scale diameter holes. In single-multiplier elements, effective gains of…
The High Energy Physics group of the University of Texas at Arlington Physics Department has been developing Gas Electron Multiplier (GEM) detectors for use as the sensitive gap detector in digital hadron calorimeters (DHCAL) for the future…
Controlled etching of copper electrodes in Gas Electron Multiplier foils allows a reduction of the material budget by more than a factor of two for a triple-GEM detector. Detectors making use of thinned foils provide performances similar to…
In this paper, a detailed investigation has been carried out to understand the physics behind GEM charging-up and its effects on gain. Experiments have been performed on both double and triple GEM with the help of 55Fe X-ray source and a…
Gas Electron Multiplier (GEM) is one of the devices for gas amplification and available as an amplification part of detectors for many experiments. A GEM with a 50 $\mu m$ thick insulator is popular and widely used in many experimental…
We have developed the gas electron multiplier (GEM) using polytetrafluoroethylene (PTFE) insulator substrate (PTFE-GEM). Carbonization on insulator layer by discharges shorts the GEM electrodes, causing permanent breakdown. Since PTFE is…
The advancement of Micro Pattern Gaseous Detector technology offers us different kinds of detectors with good spatial resolution and high rate capability and the Gas Electron Multiplier (GEM) detector is one of them. Typically GEM is made…
The Gas Electron Multiplier (GEM) technology is based on thin polymer foils cladded with copper on both the sides with a regular matrix of holes. Due to the limited manufacturing capacity of CERN, these GEM foils are now commercially…
A prototype Dual Gain Multilayer Thick Gas Electron Multilyer (DG-M-THGEM) with an active area of 10 cm $\times$ 10 cm was manufactured aiming at the production of a large-volume active-target time projection chamber which can work under…
The Gas Electron Multiplier (GEM) is a new age detector, which can handle the high flux of particles. The GEM foil, which is constructed using 50$\mu$m highly insulating foil (Kapton/Apical) coated with 5$\mu$m layers of copper, on both…
We further study the performance of single, double and triple Gas Electron Multiplier (GEM) detectors in pure noble gases at high pressures, in the range of 1-10 atm. We confirm that light noble gases, in particular He and its mixtures with…
The operation of a Micropattern Gaseous Detector (MPGD) comprising a cascade of two non-standard Gas Electron Multipliers (GEM) made from a 100 micrometer kapton foil was evaluated in pure krypton and in krypton-CO2 mixtures. The final…
Gas electron multiplier (GEM) is widely used in modern gas detectors of ionizing radiation in experiments on high-energy physics at accelerators and in other fields of science. Typically the GEM devices are based on a dielectric foil with…
Gas electron multipliers (GEMs) have been overcoated with a high resistivity 10e14 - 10e15 Ohms / square amorphous carbon layer. The coating avoids charging up of the holes and provides a constant gain immediately after switching on…
We present results on THGEM operation at low gas pressures, in the range 0.5-50 Torr. Gaseous gain up to 100000 was recorded at 10 Torr of Isobutane in a single multiplier element, with pulses rise-time in the few ns range. Cascaded…
The gain measurements of several 1 mm-thick, 10$\times$10 cm$^2$ Thick Gaseous Electron Multipliers (ThGEMs), operated in pure argon at 3.3 bar and room temperature are presented. Electrostatic simulations, performed with the COMSOL…
We study the performance of single- and double- THick Gas Electron Multiplier (THGEM) detectors in pure Hydrogen and Deuterium at low pressures, in the range of 100-450 Torr. The effect of the pressure on the maximum achievable gain,…