English
Related papers

Related papers: X-ray imaging with GEMs using $100\,\mu$m thick fo…

200 papers

Energy dispersive X-ray fluorescence (EDXRF) is a widely used non-destructive technique for micro and trace multi-element analysis of materials. Conventional trials show that using laboratory assisted EDXRF measurements, one can obtain…

Materials Science · Physics 2021-11-08 Md. Akhlak Alam , M. K. Tiwari , Ayushi Trivedi , Ajay Khooha , A. K. Singh

WEST (Tungsten Environment in Steady-State Tokamak) will be operating by the end of 2016 as a test bed for the ITER divertor components in long pulse operation. In this context, radiative cooling of highly ionized impurities like tungsten…

Spatial resolution of less than 200 um is challenging for thermal neutron detection. A novel readout scheme based on the time-projection-chamber (TPC) concept is used in a gaseous electron multiplier (GEM) detector. Thermal neutrons are…

Instrumentation and Detectors · Physics 2016-06-22 Bernhard Flierl , Otmar Biebel , Ralf Hertenberger , Karl Zeitelhack

Gas detectors are one of the pillars of the research in fundamental physics. Since many years, a new concept of detectors, the Micro Pattern Gas Detectors, allows to overcome many of the problems of other types of commonly used detectors,…

A small drift chamber was read out by means of a MediPix2 readout chip as direct anode. A Micromegas foil was placed 50 $\mu$m above the chip, and electron multiplication occurred in the gap. With a He/Isobutane 80/20 mixture, gas…

The use of GEM foils for the amplification stage of a TPC instead of a con- ventional MWPC allows one to bypass the necessity of gating, as the backdrift is suppressed thanks to the asymmetric field configuration. This way, a novel…

We have developed a novel technique for the measurement of the size of avalanche fluctuations of gaseous detectors using a gating device (gating foil) prepared for the time projection chamber in the international linear collider experiment…

We developed a prototype time projection chamber using gas electron multipliers (GEM-TPC) for high energy heavy ion collision experiments. To investigate its performance, we conducted a beam test with 3 kinds of gases (Ar(90%)-CH4(10%),…

Instrumentation and Detectors · Physics 2008-11-26 S. X. Oda , H. Hamagaki , K. Ozawa , M. Inuzuka , T. Sakaguchi , T. Isobe , T. Gunji , Y. Morino , S. Saito , Y. L. Yamaguchi , S. Sawada , S. Yokkaichi

We present the Agile REconstruction Method (AREM) for gamma-ray (30 MeV - 50 GeV) direction reconstruction applicable to high-resolution Silicon Tracker detectors in space. It can be used in a "fast mode", independently of Kalman filters…

Astrophysics · Physics 2011-07-19 Carlotta Pittori , Marco Tavani

The fast timing MPGD is a micro-pattern gaseous detector conceived for achieving sub-nanosecond time resolution while maintaining the ability to instrument large areas in high-rate environments; applications of such technology are…

Instrumentation and Detectors · Physics 2022-12-21 Antonello Pellecchia , Piet Verwilligen

The occurrence of electrical discharges in gas detectors restricts their dynamic range and degrades their performance. Among the different methods developed to mitigate discharge effects, the use of resistive materials in the detector…

Instrumentation and Detectors · Physics 2022-11-16 Abhik Jash , Luca Moleri , Shikma Bressler

The world's leading directional dark matter experiments currently all utilize low-pressure gas Time Projection Chamber (TPC) technologies. We discuss some of the challenges for this technology, for which balancing the goal of achieving the…

Instrumentation and Detectors · Physics 2024-07-19 N. S. Phan , R. J. Lauer , E. R. Lee , D. Loomba , J. A. J. Matthews , E. H. Miller

Triple-GEM detector technology was recently selected by CMS for a part of the upgrade of its forward muon detector system as GEM detectors provide a stable operation in the high radiation environment expected during the future…

Instrumentation and Detectors · Physics 2018-12-12 Aashaq Shah , CMS-Muon Collaboration

We have developed a new design of a GEM-like detector with single-layer electrodes made of a resistive kapton. This detector can operate at gains close to 10E5 even in pure Ar and Ne and if transited to discharges at higher gains they, due…

Plasma Physics · Physics 2008-11-26 R. Oliveira , V. Peskov , F. Pietropaolo , P. Picchi

Gigahertz (GHz) imaging using hard X-rays ($\gtrsim$ 10 keV) can be useful to high-temperature plasma experiments, as well as research using coherent photons from synchrotron radiation and X-ray free electron lasers. GHz framing rate can be…

Instrumentation and Detectors · Physics 2023-08-22 Zhehui Wang , C. L. Morris , J. S. Kapustinsky , K. Kwiatkowski , S. -N. Luo

This works reports on gaseous detectors developments made in the frame of the EXO double-beta decay experiment. LEM (Large Electron Multiplication) are electron amplification grids based on GEM. They were developed in Neuchatel and showed…

Instrumentation and Detectors · Physics 2007-06-12 Patrick Weber

We investigate the influence of the high voltage scheme elements on the stability of a detector based on a single $10\times10$ cm$^2$ area GEM with respect to the secondary discharge occurrence. These violent events pose a major threat to…

Instrumentation and Detectors · Physics 2019-10-09 L. Lautner , L. Fabbietti , P. Gasik , T. Klemenz

X-ray photoelectron spectroscopy (XPS) measures electron removal energies, providing direct access to core and valence electron binding energies, hence probing the electronic structure. In this work, we benchmark for the first time the ab…

Other Condensed Matter · Physics 2023-10-11 Iskander Mukatayev , Benoît Sklénard , Valerio Olevano , Jing Li

A cylindrical GEM detector is under development, to serve as an upgraded inner tracker at the BESIII spectrometer. It will consist of three layers of cylindrically-shaped triple GEMs surrounding the interaction point. The experiment is…

We describe a high resolution imaging detector based on a single 80 mm micro-channel-plate (MCP) and a phosphor screen mounted on a UHV flange of only 100 mm inner diameter. It relies on standard components and we describe its performance…

Instrumentation and Detectors · Physics 2018-05-30 Sylvain Lupone , Pierre Soulisse , Philippe Roncin