Related papers: Characteristics of multiplexing parallel beam (MPB…
Poor resolution of ultrasound images due to convolution of the tissue reflectivity function (TRF) with the system point spread function (PSF) is a major issue in medical ultrasound imaging. In this paper, we propose a correlation…
Approximate inference in probabilistic graphical models (PGMs) can be grouped into deterministic methods and Monte-Carlo-based methods. The former can often provide accurate and rapid inferences, but are typically associated with biases…
The Dynamic Cardiac SPECT (DC-SPECT) system is being developed at the Massachusetts General Hospital, featuring a static cardio focus asymmetrical geometry enabling simultaneous high resolution and high sensitivity imaging. Among 14 design…
This paper introduces a spectral Monte Carlo iterative method (SMC) for solving linear Poisson and parabolic equations driven by $\alpha$-stable L\'evy process with $\alpha\in (0,2)$, which was initially proposed and developed by Gobet and…
The geometric-mean method is often used to estimate the spatial resolution of a position-sensitive detector probed by tracks. It calculates the resolution solely from measured track data without using a detailed tracking simulation and…
The magnitude of long-range correlations between observables in two separated rapidity windows, proposed as a signature of the string fusion and percolation phenomenon, is studied in the framework of non-Glauber Monte Carlo string-parton…
Photomultiplier tubes (PMTs) are widely deployed at neutrino and dark matter experiments for photon counting. When multiple photons hit a PMT consecutively, their photo-electron (PE) pulses pile up to hinder the precise measurements of the…
We present new methods for lensing reconstruction from CMB temperature fluctuations which have smaller mean-field and reconstruction noise bias corrections than current lensing estimators, with minimal loss of signal-to-noise. These biases…
Point Spread Function (PSF) engineering is used in single emitter localization to measure the emitter position in 3D and possibly other parameters such as the emission color or dipole orientation as well. Advanced PSF models such as spline…
We introduce a revised derivation of the bitwise Markov Chain Monte Carlo (MCMC) multiple-input multiple-output (MIMO) detector. The new approach resolves the previously reported high SNR stalling problem of MCMC without the need for…
We propose a solution to the image deconvolution problem where the convolution kernel or point spread function (PSF) is assumed to be only partially known. Small perturbations generated from the model are exploited to produce a few…
Classical algorithms in numerical analysis for numerical integration (quadrature/cubature) follow the principle of approximate and integrate: the integrand is approximated by a simple function (e.g. a polynomial), which is then integrated…
An undersampled point spread function may interact with the microstructure of a solid-state detector such that the total flux detected can depend sensitively on where the PSF center falls within a pixel. Such intra-pixel sensitivity…
A method for estimating the axis of reflectional symmetry of an image $f(x,y)$ on the unit disc $D=\{(x,y):x^2+y^2\leq1\}$ is proposed, given that noisy data of $f(x,y)$ are observed on a discrete grid of edge width $\Delta$. Our estimation…
In statistical analysis, Monte Carlo (MC) stands as a classical numerical integration method. When encountering challenging sample problem, Markov chain Monte Carlo (MCMC) is a commonly employed method. However, the MCMC estimator is biased…
The key to accurate 3D shape measurement in Fringe Projection Profilometry (FPP) is the proper calibration of the measurement system. Current calibration techniques rely on phase-coordinate mapping (PCM) or back-projection stereo-vision…
We consider the problem of multiple scattering on Smith microfacets. This problem is equivalent to computing volumetric light transport in a homogeneous slab. Although the symmetry of the slab allows for significant simplification, fully…
Optically read out gaseous detectors are used in track reconstruction and imaging applications requiring high granularity images. Among resolution-determining factors, the amplification stage plays a crucial role and optimisations of…
It is demonstrated that non-constant kernel solution, that can fit the spatial variations of the kernel can be obtained with minimum computing time. The CPU cost required with this new extension of the image subtraction method is almost the…
Compact gamma cameras with a square-shaped monolithic scintillator crystal and an array of silicon photomultipliers (SiPMs) are actively being developed for applications in areas such as small animal imaging, cancer diagnostics and…