Related papers: Performance of the LHCb Outer Tracker
The CMS Resistive Plate Chamber (RPC) system has been certified for 10 years of LHC operation. In the next years, during the High luminosity LHC (HL-LHC) phase, the LHC instantaneous luminosity will increase to a factor five more than the…
Since the end of Run 1 of the LHC in 2012, the outermost ring has been added to the CMS Cathode Strip Chambers (CSC) endcap muon detector, and the readout electronics of the innermost ring of CSCs have been upgraded to accommodate the…
The ATLAS experiment has been taking data efficiently since LHC collisions started, first at the injection energy of 450 GeV/beam and at 1.18 TeV/beam in 2009, then at 3.5 TeV/beam in 2010. Many results have already been obtained based on…
The efficiency to identify jets containing $b$-hadrons ($b$-jets) is measured using a high purity sample of dileptonic top quark-antiquark pairs ($t\bar{t}$) selected from the 36.1 fb$^{-1}$ of data collected by the ATLAS detector in 2015…
An overview of LHCb experiment is given, focusing on detector, trigger and expected physics performances. LHCb is a second generation b physics experiment design to do precise measurements of CP violation in B meson system and to study b…
The installation of a new sub-detector has improved the ability of LHCb to measure central exclusive production in Run 2 at the LHC. A measurement of central exclusive $J/\psi$ production is presented and improvements for the analysis of…
The MATHUSLA detector to be installed on the surface above and somewhat displaced from the CMS interaction point (IP) will cover an area of $100\times 100$ m$^2$ containing many layers of scintillators planes to establish the space and time…
The combined vertexing and tracking performance of the innermost part of the FCC-ee experiments must deliver outstanding precision for measurement of the track momentum together with an impact parameter resolution exceeding by at least a…
A four-gap glass RPC with 0.3mm gap size was tested with hadron beam as a time-of-flight detector having a time resolution of ~ 100ps. A thickness of the detector together with front-end electronics is ~ 12mm. Results on time resolution…
This report presents results from a background measurement campaign for the CODEX-b proposal undertaken in August, 2018. The data were recorded in the DELPHI side of the LHCb cavern behind a 3.2~m concrete shield wall, during Run~2…
The ALICE Collaboration will undertake a major upgrade of the detector apparatus during the second LHC Long Shutdown LS2 (2019-2020) in view of the Runs 3 and 4 (2021-2029). The objective of the upgrade is two-fold: i) an improvement of the…
The LHCb experiment is set for a significant upgrade, which will be ready for Run 3 of the LHC in 2020. This upgrade will allow LHCb to run at a significantly higher instantaneous luminosity and collect an integrated luminosity of…
With over 200 square meters of sensitive Silicon and almost 10 million readout channels, the Silicon Strip Tracker of the CMS experiment at the LHC will be the largest Silicon strip detector ever built. The design, construction and expected…
The physics motivation, detector design, triggers, calibration, alignment, simulation, and overall performance of the very forward CASTOR calorimeter of the CMS experiment are reviewed. The CASTOR Cherenkov sampling calorimeter is located…
The Tile hadronic calorimeter of the ATLAS detector has undergone extensive testing in the experimental hall since its installation in late 2005. The readout, control and calibration systems have been fully operational since 2007 and the…
Optical readout of large Time Projection Chambers (TPCs) with multiple Gas Electron Multipliers (GEMs) amplification stages has shown to provide very interesting performances for high energy particle tracking. Proposed applications for…
The muon detector of LHCb, which comprises 1368 multi-wire-proportional-chambers (MWPC) for a total area of 435 m2, is the largest instrument of its kind exposed to such a high-radiation environment. In nine years of operation, from 2010…
A second major upgrade of the LHCb detector is necessary to allow full exploitation of the HL-LHC for flavour physics. The new detector will be installed during long shutdown 4 (LS4), and will operate at instantaneous luminosity up to $1.5…
The LHCb Vertex Locator (VELO) is a silicon strip detector designed to reconstruct charged particle trajectories and vertices produced at the LHCb interaction region. During the first two years of data collection, the 84 VELO sensors have…
Silicon trackers at the SLHC will suffer high radiation damage from particles produced during the collisions, which leads to high leakage currents. Reducing these currents in the sensors requires efficient cooling to -30 C. The large heat…