English
Related papers

Related papers: Development of a sub-milimeter position sensitive …

200 papers

New Micromegas (Micro-mesh gaseous detectors) are being developed in view of the future physics projects planned by the COMPASS collaboration at CERN. Several major upgrades compared to present detectors are being studied: detectors…

The paper reviews recent progress in photodetectors, discussing vacuum-based detectors, semiconductor sensors, and gas-based detectors. The emphasis in this review is on the detection of low light levels, enhanced timing resolution, and…

Instrumentation and Detectors · Physics 2024-01-12 Peter Krizan

The COSINE-100 dark matter search experiment has started taking physics data with the goal of performing an independent measurement of the annual modulation signal observed by DAMA/LIBRA. A muon detector was constructed by using plastic…

Triple-GEM detectors for the GE2/1 and ME0 stations of the endcap muon system for the Phase-2 upgrade of the CMS Experiment have been operated in a test beam to measure their efficiency and spatial resolution, together with a high spatial…

Instrumentation and Detectors · Physics 2022-11-23 Antonello Pellecchia , Piet Verwilligen , Anna Stamerra

Cosmic-ray muons, owing to their high penetration power and abundance, have been widely employed as a natural probe in experimental particle physics. We developed a meter-scale cosmic-ray muon telescope, consisting of two parallel…

High Energy Physics - Experiment · Physics 2026-05-07 Yan Niu , Anqing Wang , Xiangxiang Ren , Dong Liu , Meng Wang

Current radiation portal monitors at sea ports and international borders that employ standard radiation detection techniques are not very sensitive to nuclear contraband that is well shielded to absorb emanating radiation. Muon Tomography…

Instrumentation and Detectors · Physics 2016-11-17 M. Hohlmann , K. Gnanvo , L. Grasso , J. B. Locke , A. Quintero , D. Mitra

A semiconductor tracker for muon scattering tomography is presented. The tracker contains silicon strip sensors with an $80\,\mu$m pitch, precision mechanics and integrated cooling. The electronic readout of the sensors is performed by a…

Instrumentation and Detectors · Physics 2018-10-30 F. Keizer , A. Gorbatch , M. A. Parker , C. Steer , S. A. Wotton

The off-axis magnetic near detector of the T2K experiment has undergone a significant upgrade, including the construction and installation of two new Time Projection Chambers featuring innovative resistive Micromegas technology and a field…

Muon tomography is a non-destructive imaging technique that exploits cosmic-ray muons from multiple directions. Its performance critically depends on the stability, active-area coverage, and spatial resolution of position-sensitive…

Instrumentation and Detectors · Physics 2025-12-02 Yiyue Li , Huiling Li , Hui Liang , Cong Liu , Chenghan Lv , Hongbo Wang , Weiwei Xu

A measurement is presented of the flux ratio of positive and negative muons from cosmic ray interactions in the atmosphere, using data collected by the CMS detector at ground level and in the underground experimental cavern. The excellent…

High Energy Physics - Experiment · Physics 2011-04-22 Lars Sonnenschein

We describe and show results of a photographic technique for continuously monitoring the position, orientation, and shape of a thin-film muon stopping target for the MEG II experiment. The measurement is complicated by the target being…

Instrumentation and Detectors · Physics 2019-10-02 D. Palo , M. Hildebrandt , A. Hofer , W. Kyle , D. Lad , T. Libeiro , W. Molzon

The MicroBooNE detector is a liquid argon time projection chamber at Fermilab designed to study short-baseline neutrino oscillations and neutrino-argon interaction cross-section. Due to its location near the surface, a good understanding of…

High Energy Physics - Experiment · Physics 2023-02-17 MicroBooNE collaboration , R. Acciarri , C. Adams , R. An , J. Anthony , J. Asaadi , M. Auger , L. Bagby , S. Balasubramanian , B. Baller , C. Barnes , G. Barr , M. Bass , F. Bay , M. Bishai , A. Blake , T. Bolton , L. Camilleri , D. Caratelli , B. Carls , R. Castillo Fernandez , F. Cavanna , H. Chen , E. Church , D. Cianci , E. Cohen , G. H. Collin , J. M. Conrad , M. Convery , J. I. Crespo-Anadon , M. Del Tutto , D. Devitt , S. Dytman , B. Eberly , A. Ereditato , L. Escudero Sanchez , J. Esquivel , A. A. Fadeeva , B. T. Fleming , W. Foreman , A. P. Furmanski , D. Garcia-Gamez , G. T. Garvey , V. Genty , D. Goeldi , S. Gollapinni , N. Graf , E. Gramellini , H. Greenlee , R. Grosso , R. Guenette , A. Hackenburg , P. Hamilton , O. Hen , V Hewes , C. Hill , J. Ho , G. Horton-Smith , A. Hourlier , E. -C. Huang , C. James , J. Jan de Vries , C. -M. Jen , L. Jiang , R. A. Johnson , J. Joshi , H. Jostlein , D. Kaleko , L. N. Kalousis , G. Karagiorgi , W. Ketchum , B. Kirby , M. Kirby , T. Kobilarcik , I. Kreslo , G. Lange , A. Laube , Y. Li , A. Lister , B. R. Littlejohn , S. Lockwitz , D. Lorca , W. C. Louis , M. Luethi , B. Lundberg , X. Luo , A. Marchionni , C. Mariani , J. Marshall , D. A. Martinez Caicedo , V. Meddage , T. Miceli , G. B. Mills , J. Moon , M. Mooney , C. D. Moore , J. Mousseau , R. Murrells , D. Naples , P. Nienaber , J. Nowak , O. Palamara , V. Paolone , V. Papavassiliou , S. F. Pate , Z. Pavlovic , R. Pelkey , E. Piasetzky , D. Porzio , G. Pulliam , X. Qian , J. L. Raaf , A. Rafique , L. Rochester , C. Rudolf von Rohr , B. Russell , D. W. Schmitz , A. Schukraft , W. Seligman , M. H. Shaevitz , J. Sinclair , A. Smith , E. L. Snider , M. Soderberg , S. Soldner-Rembold , S. R. Soleti , P. Spentzouris , J. Spitz , J. St. John , T. Strauss , A. M. Szelc , N. Tagg , K. Terao , M. Thomson , M. Toups , Y. -T. Tsai , S. Tufanli , T. Usher , W. Van De Pontseele , R. G. Van de Water , B. Viren , M. Weber , D. A. Wickremasinghe , S. Wolbers , T. Wongjirad , K. Woodruff , T. Yang , L. Yates , G. P. Zeller , J. Zennamo , C. Zhang

The paper summarizes our latest progress in the development of newly introduced micro pattern gaseous detectors with resistive electrodes. These resistive electrodes protect the detector and the front-end electronics in case of occasional…

Instrumentation and Detectors · Physics 2008-11-26 A. Di Mauro , B. Lund-Jensen , P. Martinengo , E. Nappi , R. Oliveira , V. Peskov , L. Periale , P. Picchi , F. Pietropaolo , I. Rodionov , J. C. Santiard

The characteristics of triple GEM detectors have been studied systematically by using cosmic ray muons. The minimum ionizing particle (MIP) spectra has been taken for different GEM voltage setting. Efficiency of GEM detector has been…

Instrumentation and Detectors · Physics 2015-06-17 S. Biswas , D. J. Schmidt , A. Abuhoza , U. Frankenfeld , C. Garabatos , J. Hehner , V. Kleipa , T. Morhardt , C. J. Schmidt , H. R. Schmidt , J. Wiechula

The main characteristics of a new concept of spherical gaseous detectors, with some details on its operation are first given. The very low energy threshold of such detector has led to investigations of its potential performance for dark…

Instrumentation and Methods for Astrophysics · Physics 2014-01-31 G. Gerbier , I. Giomataris , P. Magnier , A. Dastgheibi , M. Gros , D. Jourde , E. Bougamont , X. F. Navick , T. Papaevangelou , J. Galan , J. Derre , I. Savvidis , G. Tsiledakis

Gas-filled Time Projection Chambers (TPCs) with Gas Electron Multipliers (GEMs) and pixels appear suitable for direction-sensitive WIMP dark matter searches. We present the background and motivation for our work on this technology, past and…

Instrumentation and Methods for Astrophysics · Physics 2015-05-30 S. E. Vahsen , H. Feng , M. Garcia-Sciveres , I. Jaegle , J. Kadyk , Y. Nguyen , M. Rosen , S. Ross , T. Thorpe , J. Yamaoka

In the context of the 2013 APS-DPF Snowmass summer study conducted by the U.S. HEP community, this white paper outlines a roadmap for further development of Micro-pattern Gas Detectors for tracking and muon detection in HEP experiments. We…

Instrumentation and Detectors · Physics 2013-09-06 M. Hohlmann , V. Polychronakos , A. White , J. Yu

We propose to use stopping cosmic-ray muons in the energy calibration of planned and deployed large underwater detectors. The method is based on the proportionality between the incident muon energy and the length of the muon path before it…

High Energy Physics - Experiment · Physics 2009-10-31 V. A. Kudryavtsev , R. A. Brook , S. L. Cartwright , J. E. McMillan , N. J. C. Spooner , L. F. Thompson