Related papers: Laboratory studies of THGEM-based WELL structures …
We study the performance of the triple GEM (Gas Electron Multiplier) detector in pure noble gases He and Kr at high pressures, varying from 1 to 15 atm. The operation in these gases is compared to that recently studied in Ne, Ar and Xe. It…
A Bethe-Ansatz spin-density functional approach is developed to evaluate the ground-state density profile in a system of repulsively interacting spin-1/2 fermions inside a quasi-one-dimensional harmonic well. The approach allows for the…
The batch settling test is widely used to estimate the compressive rheology of strongly flocculated colloidal suspensions, in particular the compressive yield strength and hydraulic permeability. Recently it has been discovered that wall…
A new family of spark-protected micropattern gaseous detectors is introduced: a 2-D sensitive restive microstrip counter and hybrid detectors, which combine in one design a resistive GEM with a microstrip detector. These novel detectors…
The design and operation of a differential Polymer Electrolyte Membrane (PEM) fuel cell is described. The fuel cell design is based on coupled Stirred Tank Reactors (STR); the gas phase in each reactor compartment was well mixed. The…
A well-balanced detector with high sensitivity and low noise is presented in this paper. The two-stage amplification structure is used to increase electronic gain while keeping an effective bandwidth of about 70 MHz. In order to further…
We report here on the optimization of 0.5 cm thick pixelated Orbotech CZT detectors with regards to the best contacting materials and the use of steering grids. We evaluated the performance of different contacting materials. Our study…
The characteristic properties of two-phase Ar avalanche detectors, including those obtained with CsI photocathode, are further studied. Such detectors are relevant in the field of coherent neutrino-nucleus scattering and dark matter search…
Resistive-anode Micromegas detectors are in development since several years, in an effort to solve the problem of sparks when working in high flux and high radiations environment like in the HL-LHC (ten times the luminosity of the LHC).…
Temperature coefficient of resistance (TCR) of a bolometer can be tuned by modifying the thermal conductance of an absorbing materials since they sense radiations via the temperature change in the absorber. However, the thermal conductance…
Selene is the attempt to implement a new scheme for high-intensity specular reflectometry. Instead of a highly collimated beam one uses a convergent beam covering a large angular range. The angular resolution is then performed by a…
The structural properties of the ROFeM (R=La, Nd; M=As, P) materials have been analyzed by means of electron diffraction, high-resolution transmission-electron microscopy (TEM) and in-situ cooling TEM observations. The experimental results…
A new anode support structure for the spherical proportional counter is presented that incorporates a resistive correction electrode made of glass. This electrode improves the electric field homogeneity versus angle while suppressing the…
Thin-wall metal ultramicro- and nanoelectrodes (UMEs/NEs), especially gold NEs, are indispensable for high-resolution electrochemical microscopy, biosensing, and fundamental research. However, their damage susceptibility and the lack of…
We present a structural and high frequency (8.72GHz) electrical characterization of sputter deposited Ti/W, Ti/Ru and Mo/Ti metallic multilayers for potential application as acoustic Bragg reflectors. We prove that all metallic multilayers…
We show that isolated Weyl nodes can arise in a system of parallel topological insulator nano-wires arranged in a honeycomb fashion. This introduces another theoretical example of a topological semi-metal phase with more than one pair of…
We demonstrate a controllable electromagnetic wave reflector/absorber for different polarizations with metamaterial involving electromagnetic resonant structures coupled with diodes. Through biasing at different voltages to turn ON and OFF…
The time resolution of a double-stage Thick-GEM (THGEM) detector was measured with UV-photons and relativistic electrons. The photon detector, with semitransparent- or reflective-photocathode yielded time resolution of about 8-10ns RMS for…
The 30 and 44 GHz Back End Modules (BEM) for the Planck Low Frequency Instrument are broadband receivers (20% relative bandwidth) working at room temperature. The signals coming from the Front End Module are amplified, band pass filtered…
In this work we describe a parallel geometry gaseous detector constituted by a thin (0.6 mm) amplifying gap preceded by a drift region. The gap is delimited by a metal plate and by a wire mesh. The detector can count up to a rate of 10^7…