English
Related papers

Related papers: Discrete Imaging Models for Three-Dimensional Opto…

200 papers

Photoacoustic tomography (PAT) is an emerging imaging modality that aims at measuring the high-contrast optical properties of tissues by means of high-resolution ultrasonic measurements. The interaction between these two types of waves is…

Analysis of PDEs · Mathematics 2021-07-27 Giovanni S. Alberti , Paolo Campodonico , Matteo Santacesaria

Optical Coherence Tomography (OCT) is one of the most emerging imaging modalities that has been used widely in the field of biomedical imaging. From its emergence in 1990's, plenty of hardware and software improvements have been made. Its…

Computer Vision and Pattern Recognition · Computer Science 2014-11-18 Ahmadreza Baghaie , Roshan M. D'souza , Zeyun Yu

Quantitative tissue information, like the light scattering properties, is considered as a key player in the detection of cancerous cells in medical diagnosis. A promising method to obtain these data is optical coherence tomography (OCT). In…

Numerical Analysis · Mathematics 2023-06-21 Leopold Veselka , Peter Elbau , Leonidas Mindrinos , Lisa Krainz , Wolfgang Drexler

Photoacoustic imaging (PAI) and ultrasound imaging (USI) are important biomedical imaging techniques, due to their unique and complementary advantages in tissue's structure and function visualization. In this Letter, we proposed a coaxial…

Medical Physics · Physics 2024-11-12 Yunhui Jiang , Fan Zhang , Yuwei Zheng , Ruixi Sun , Fei Gao

Optical coherence tomography (OCT) is a micrometer-scale, volumetric imaging modality that has become a clinical standard in ophthalmology. OCT instruments image by raster-scanning a focused light spot across the retina, acquiring…

Image and Video Processing · Electrical Eng. & Systems 2022-09-16 Stefan Ploner , Siyu Chen , Jungeun Won , Lennart Husvogt , Katharina Breininger , Julia Schottenhamml , James Fujimoto , Andreas Maier

In this paper we consider the problem of acoustic inversion in the context of the optoacoustic tomography image reconstruction problem. By leveraging the ability of the recently proposed diffusion models for image generative tasks among…

Image and Video Processing · Electrical Eng. & Systems 2024-04-17 M. G. González , M. Vera , A. Dreszman , L. J. Rey Vega

Photoacoustic Tomography (PAT) is an emerging biomedical "imaging from coupled physics" technique, in which the image contrast is due to optical absorption, but the information is carried to the surface of the tissue as ultrasound pulses.…

Numerical Analysis · Mathematics 2016-11-03 Simon R. Arridge , Marta M. Betcke , Ben T. Cox , Felix Lucka , Brad E. Treeby

Photoacoustic tomography (PAT) is a hybrid medical imaging technique that offer high contrast and a high spatial resolution. One challenging mathematical problem associated with PAT is reconstructing the initial pressure of the wave…

Numerical Analysis · Mathematics 2024-07-16 Gyeongha Hwang , Gihyeon Jeon , Sunghwan Moon , Dabin Park

The literature on reconstruction formulas for photoacoustic tomography (PAT) is vast. The various reconstruction formulas differ by used measurement devices and geometry on which the data are sampled. In standard photoacoustic imaging…

Analysis of PDEs · Mathematics 2015-05-30 Peter Elbau , Otmar Scherzer , Rainer Schulze

Limited-view artefacts are commonly present in optoacoustic tomography images, mainly due to practical geometrical and physical constraints imposed by the imaging systems as well as limited light penetration into large optically opaque…

Optics · Physics 2015-12-11 X L Dean-Ben , L Ding , D Razansky

A new formulation of lateral imaging process of point-scanning optical coherence tomography (OCT) and a new differential contrast method designed by using this formulation are presented. The formulation is based on a mathematical sample…

Segmentation of biomedical images is essential for studying and characterizing anatomical structures, detection and evaluation of pathological tissues. Segmentation has been further shown to enhance the reconstruction performance in many…

Medical Physics · Physics 2019-01-11 Subhamoy Mandal , Xosé Luís Deán-Ben , Daniel Razansky

Optical coherence tomography (OCT) is a prevalent non-invasive imaging method which provides high resolution volumetric visualization of retina. However, its inherent defect, the speckle noise, can seriously deteriorate the tissue…

Computer Vision and Pattern Recognition · Computer Science 2022-01-31 Dewei Hu , Yuankai K. Tao , Ipek Oguz

Iterative model-based image reconstruction in photoacoustic tomography (PAT) enables principled incorporation of detector physics, object-related priors, and complex acquisition strategies. However, for three-dimensional (3D) imaging…

Acoustic-resolution optoacoustic microscopy (AR-OAM) retrieves anatomical and functional contrast from living tissues at depths not reachable with optical microscopy. The imaging performance of AR-OAM has been advanced with image…

Photoacoustic tomography (PAT) is a hybrid imaging modality that intends to construct high-resolution images of optical properties of heterogeneous media from measured acoustic data generated by the photoacoustic effect. To date, most of…

Numerical Analysis · Mathematics 2019-08-07 Christina Frederick , Kui Ren , Sarah Vallélian

Dynamic Photoacoustic Computed Tomography (PACT) is an important imaging technique for monitoring physiological processes, capable of providing high-contrast images of optical absorption at much greater depths than traditional optical…

Image and Video Processing · Electrical Eng. & Systems 2025-06-05 Youshen Xiao , Yiling Shi , Ruixi Sun , Hongjiang Wei , Fei Gao , Yuyao Zhang

In photoacoustic tomography (PAT), a hybrid imaging modality that is based on the acoustic detection of optical absorption from biological tissue exposed to a pulsed laser, a short pulse laser generates an initial pressure proportional to…

Numerical Analysis · Mathematics 2026-03-27 Sunghwan Moon , Anwesa Dey , Souvik Roy

Photoacoustic microscopy with large depth of focus is significant to the biomedical research. The conventional optical-resolution photoacoustic microscope (OR-PAM) suffers from limited depth of field (DoF) since the employed focused…

Image and Video Processing · Electrical Eng. & Systems 2020-09-07 Xianlin Song , Jianshuang Wei , Lingfang Song

Optical coherence tomography (OCT) uses low-coherence reflectometry to obtain cross-sectional images of inhomogeneous media, such as biological tissue. OCT is particularly useful in the biomedical ea, since the imaging can be performed…

Medical Physics · Physics 2018-03-01 Takahisa Mitsui , Kenichiro Aoki