English
Related papers

Related papers: Simulation study on light ions identification meth…

200 papers

Topological and kinematical characteristics of hadron interactions have been studied using a lead-emulsion target exposed to 2, 4 and 10 GeV/c hadron beams. A total length of 60 m $\pi^-$ tracks was followed using a high speed automated…

Monte Carlo simulations are powerful tools for understanding the effects of radiation interactions within detector devices allowing not only to evaluate typical estimates for experimental measurements and to serve as means for designing…

Instrumentation and Detectors · Physics 2016-02-09 F. Marinho , K. Akiba

A beam line for electrons with energies in the range of 1 to 45 GeV, low contamination of hadrons and muons and high intensity up to 10^6 per accelerator spill at 27 GeV was setup at U70 accelerator in Protvino, Russia. A beam tagging…

The MCNP code was used to study the characteristics of gamma radiation field with collimated beam geometry. A close-to-reality simulation model of the facility was used for calculation air-kerma along the whole range of…

Instrumentation and Detectors · Physics 2015-02-11 Fei Gao

A simple Monte Carlo (MC) algorithm for the simulation of the passage of low-energy gamma rays and electrons through any material medium is presented. The algorithm includes several approximations that accelerate the simulation while…

Accelerator Physics · Physics 2023-10-25 Víctor Moya , Jaime Rosado , Fernando Arqueros

The fragmentation cross sections of carbon ion beams with kinetic energies of $115 - 353~\text{MeV/u}$ impinging on thin targets of graphite (C), polyvinyl-toluene (C$_9$H$_{10}$) and PMMA (C$_2$O$_5$H$_8$) have been measured at…

To overcome the problem of inefficient computing time and unreliable results in MCNP5 calculation, a two-step method is adopted to calculate the energy deposition of prompt gamma-rays in detectors for depleted uranium spherical shells under…

Instrumentation and Detectors · Physics 2016-08-03 Jianguo Qin , Caifeng Lai , Rong Liu , Tonghua Zhu , Xinwei Zhang , Bangjiao Ye

Electron emission spectra of a thin gold foil after photon interaction were measured over the energy range between 50 eV and 9500 eV to provide reference data for Monte Carlo radiation-transport simulations. Experiments were performed with…

Restricted path integral Monte Carlo simulations are used to calculate the equilibrium properties of hydrogen in the density and temperature range of $9.83 \times 10^{-4}\rm \leq \rho \leq 0.153 \rm gcm^{-3}$ and $5000 \leq T \leq 250 000…

Plasma Physics · Physics 2009-11-07 B. Militzer , D. M. Ceperley

A module of the ATLAS electromagnetic barrel liquid argon calorimeter was exposed to the CERN electron test-beam at the H8 beam line upgraded for precision momentum measurement. The available energies of the electron beam ranged from 10 to…

Instrumentation and Detectors · Physics 2008-11-26 M. Aharrouche , ATLAS Electromagnetic Barrel Calorimeter Collaboration

In this work, the simulation of optical photons is carried out in an antineutrino detector module consisting of a plastic scintillator connected to light guides and photomultipliers on both ends, which is considered to be used for remote…

Instrumentation and Detectors · Physics 2018-05-23 Mustafa Kandemir , Altan Cakir

The energetic bremsstrahlung photons up to 100 MeV produced in heavy ion collisions can be used as a sensitive probe to the short range correlation in atomic nuclei. The energy of the $\gamma$-rays can be measured by collecting the…

Instrumentation and Detectors · Physics 2025-06-09 Dawei Si , Yan Zhou , Sheng Xiao , Zhigang Xiao

Characterization of a hybrid ${\it telescope}$ with gas transmission detector ($\Delta$E) and a solid-state stop detector (E) has been fabricated for detection of low energy $\alpha$ particles between 5 to 1 MeV. The detector is developed…

Instrumentation and Detectors · Physics 2021-08-26 Rajkumar Santra , Subinit Roy

The MINERvA collaboration operated a scaled-down replica of the solid scintillator tracking and sampling calorimeter regions of the MINERvA detector in a hadron test beam at the Fermilab Test Beam Facility. This article reports measurements…

A possibility of a few MeV electron beam diagnostics (Lorentz factor ~ 10) using polarization characteristics of the optical transition radiation (OTR) have been considered. Determinaton of the electron beam divergence have been performed…

IDEA (Innovative Detector for an Electron-positron Accelerator) is a general-purpose detector concept, designed to study electron-positron collisions in a wide energy range from a very large circular leptonic collider. Its drift chamber is…

The MINER$\nu$A TestBeam Detector calibrations will take place in the MTEST facility at Fermilab. It will use a beam of hadrons between 300 and 1500 MeV/c to analyze the response of the MINERvA detector components. The aim of the present…

Instrumentation and Detectors · Physics 2008-08-05 C. E. Pérez , A. M. Gago , J. Morfin , D. A. Jensen , R. Gran

The design, construction and performance characteristics of a simple axial-field ionization chamber suitable for identifying ions in a radioactive beam are presented. Optimized for use with low-energy radioactive beams (< 5 MeV/A) the…

Instrumentation and Detectors · Physics 2016-10-12 J. Vadas , Varinderjit Singh , G. Visser , A. Alexander , S. Hudan , J. Huston , B. B. Wiggins , A. Chbihi , M. Famiano , M. M. Bischak , R. T. deSouza

An ab initio quantum Monte Carlo method is introduced for calculating total rates of muon weak capture in light nuclei with mass number $A \leq 12$. As a first application of the method, we perform a calculation of the rate in $^4$He in a…

Nuclear Theory · Physics 2019-09-18 A. Lovato , N. Rocco , R. Schiavilla

By using an experimental setup based on thin and thick double-sided microstrip silicon detectors, it has been possible to identify the fragmentation products due to the interaction of very high energy primary ions on different targets. Here…