English
Related papers

Related papers: A near-field scanning SQUID microwave microscope

200 papers

We present a design for a tunneling-current-assisted scanning near-field microwave microscope. For stable operation at cryogenic temperatures, making a small and rigid microwave probe is important. Our coaxial resonator probe has a length…

Mesoscale and Nanoscale Physics · Physics 2016-06-13 Hideyuki Takahashi , yoshinori imai , Atsutaka Maeda

Scaling of multi-pixel cryogenic detectors for imaging becomes increasingly difficult with size due to complexity of readout circuitry and cryogenic constraints (thermal load from wiring). We propose and demonstrate a new readout scheme…

Instrumentation and Detectors · Physics 2007-05-23 Miha Furlan , Eugenie Kirk , Alex Zehnder

Scanning superconducting quantum interference device (SQUID) microscopy is a magnetic imaging technique combining high-field sensitivity with nanometer-scale spatial resolution. State-of-the-art SQUID-on-tip probes are now playing an…

Mesoscale and Nanoscale Physics · Physics 2022-03-03 M. Wyss , K. Bagani , D. Jetter , E. Marchiori , A. Vervelaki , B. Gross , J. Ridderbos , S. Gliga , C. Schönenberger , M. Poggio

A microwave kinetic inductance detector (MKID) is a cutting-edge superconducting detector. It comprises a resonator circuit constructed with a superconducting film on a dielectric substrate. To expand its field of application, it is…

Instrumentation and Detectors · Physics 2022-03-16 Yoshinori Sueno , Shunsuke Honda , Hiroki Kutsuma , Satoru Mima , Chiko Otani , Shugo Oguri , Junya Suzuki , Osamu Tajima

We believe that the best chance to observe macroscopic quantum coherence (MQC) in a rf-SQUID qubit is to use on-chip RSFQ digital circuits for preparing, evolving and reading out the qubit's quantum state. This approach allows experiments…

We report on the design and performance of a cryogenic (300 mK) near-field scanning microwave microscope. It uses a microwave resonator as the near-field sensor, operating at a frequency of 6 GHz and microwave probing amplitudes down to 100…

Mesoscale and Nanoscale Physics · Physics 2014-04-03 S. E. de Graaf , A. V. Danilov , A. Adamyan , S. E. Kubatkin

A flux qubit readout scheme involving a dispersive technique coupled to a microstrip squid amplifier has been tested experimentally. Thanks to the almost quantum limited noise of this amplifier at low temperature, this readout device is…

Superconductivity · Physics 2008-12-02 Sebastien Michotte

A seven-channel system capable of performing both magnetoencephalography (MEG) and ultra-low-field magnetic resonance imaging (ULF MRI) is described. The system consists of seven second-order SQUID gradiometers with 37 mm diameter and 60 mm…

We implement a broadly tunable phase shifter for microwaves based on superconducting quantum interference devices (SQUIDs) and study it both experimentally and theoretically. At different frequencies, a unit transmission coefficient,…

The magnetic sensing at nanoscale level is a promising and interesting research topic of nanoscience. Indeed, magnetic imaging is a powerful tool for probing biological, chemical and physical systems. The study of small spin cluster, like…

Superconductivity · Physics 2016-01-12 Carmine Granata , Antonio Vettoliere

We have developed a quantitative theory of resonant tunneling of magnetic flux between discrete macroscopically distinct quantum states in SQUID systems. The theory is based on the standard density-matrix approach. Its new elements include…

Mesoscale and Nanoscale Physics · Physics 2009-10-31 D. V. Averin , Jonathan R. Friedman , J. E. Lukens

The current-voltage characteristics of Superconducting Quantum Interference Devices (SQUIDs) are known to modulate as a function of applied magnetic field with a period of one flux quantum $\Phi_0=h$/2e. Here we report on the fabrication…

Superconductivity · Physics 2007-05-23 C. W. Schneider , G. Hammerl , G. Logvenov , T. Kopp , J. R. Kirtley , P. J. Hirschfeld , J. Mannhart

The properties of Josephson devices are strongly affected by geometrical effects. A loop-shaped superconducting electrode tightly couples a long Josephson tunnel junction with the surrounding electromagnetic field. Due to the fluxoid…

Superconductivity · Physics 2013-04-23 Roberto Monaco

We propose to use the quantum properties of a superconducting flux qubit in the construction of a magnetometer with quantum limited sensitivity. The main advantage of a flux qubit is that its noise is rather low, and its transfer functions…

Superconductivity · Physics 2007-05-23 E. Il'ichev , Ya. S. Greenberg

We propose tunable superconducting split-ring resonators (SRRs) employing nonlinear Josephson inductance. A fraction of SRR is replaced by Nb-AlOx-Nb Josephson tunnel junctions connected in parallel and forming a superconducting quantum…

Superconductivity · Physics 2015-06-17 A. Vidiborskiy , V. P. Koshelets , L. V. Filippenko , S. V. Shitov , A. V. Ustinov

Micron-sized superconducting interference devices ($\mu$-SQUIDs) based on constrictions optimized for minimizing thermal runaway are shown to exhibit voltage oscillations with applied magnetic flux despite their hysteretic behavior. We…

Superconductivity · Physics 2018-11-28 Sourav Biswas , Clemens B. Winkelmann , Hervé Courtois , Anjan K. Gupta

Magnetic resonance imaging at ultra-low fields (ULF MRI) is a promising new imaging method that uses SQUID sensors to measure the spatially encoded precession of pre-polarized nuclear spin populations at a microtesla-range measurement…

Medical Physics · Physics 2007-10-18 V. S. Zotev , A. N. Matlashov , P. L. Volegov , A. V. Urbaitis , M. A. Espy , R. H. Kraus

We realize tunable coupling between two superconducting transmission line resonators. The coupling is mediated by a non-hysteretic rf SQUID acting as a flux-tunable mutual inductance between the resonators. From the mode distance observed…

Miniaturization of superconducting quantum interference devices (SQUIDs) is of major importance for the development of sensitive scanning nanoscale magnetometry tools. The high sensitivity of nanoSQUIDs is restricted, however, to only…

Superconductivity · Physics 2016-11-28 Alexander Y. Meltzer , Aviram Uri , Eli Zeldov

We provide a quantum analysis of a DC SQUID mechanical displacement detector within the sub-critical Josephson current regime. A segment of the SQUID loop forms the mechanical resonator and motion of the latter is transduced inductively…

Superconductivity · Physics 2009-11-13 M. P. Blencowe , E. Buks