Wire chambers are routinely operated as tracking detectors in magnetic spectrometers at high-intensity continuous electron beams. Especially in experiments studying reactions with small cross-sections the reaction yield is limited by the…
We present a fast neutron spectroscopy system based on a nitrogen-filled, large volume gaseous detector, the Spherical Proportional Counter. The system has been successfully operated up to gas pressure of 1.5 bar. Neutron energy is…
A tracking detector system has been constructed with an innovative approach to the classical multi-wire proportional chamber concept, using contemporary technologies. The detectors, covering an area of 0.58 square meters each, are optimized…
A high-efficiency fast neutron detector prototype based on a triple Gas Electron Multiplier (GEM) detector, which coupled with a novel multi-layered High-Density PolyEthylene (HDPE) as a neutron-to-proton converter for improving the neutron…
The legacy of solar neutrinos suggests that large neutrino detectors should be sited underground. However, to instead go underwater bypasses the need to move mountains, allowing much larger water Cherenkov detectors. We show that reaching a…
Fission events from Special Nuclear Material (SNM), such as highly enriched uranium or plutonium, can produce simultaneous emission of multiple neutrons and high energy gamma-rays. The observation of time correlations between any of these…
Neutron production in lead by cosmic muons has been studied with a Gadolinium doped liquid scintillator detector. The detector was installed next to the Muon-Induced Neutron Indirect Detection EXperiment (MINIDEX), permanently located in…
The construction of a micro-pattern gas detector of dimensions 40x10 cm**2 is described. Two gas electron multiplier foils (GEM) provide the internal amplification stages. A two-layer readout structure was used, manufactured in the same…
Dark matter detectors that utilize liquid xenon have now achieved tonne-scale targets, giving them sensitivity to all flavours of supernova neutrinos via coherent elastic neutrino-nucleus scattering. Considering for the first time a…
The miniBELEN detector is a moderated neutron counter based on the use of $^3$He tubes and high-density polyethylene as moderator. The detector has been designed to have a neutron detection efficiency that is nearly independent from the…
We have developed and tested several prototypes of GEM-like detectors with electrodes coated with resistive layers: CuO or CrO. These detectors can operate stably at gains close to 10E5 and they are very robust. We discovered that the…
An efficient neutron detection system with good energy resolution is required to correctly characterize decays of neutron-rich nuclei where $\beta-$delayed neutron emission is a dominant decay mode. The Neutron dEtector with Xn Tracking…
The neutron capture is a process that concerns most of the nuclei used to build our detectors. This process produces protons, alpha particles, and gamma rays which generate background signals. Characterizing this background is important for…
Amorphous boron carbide (B4C) thin films are by far the most popular form for the neutron converting layers in the 10B-based neutron detectors, which are a rising trend in detector technologies in response to the increasing scarcity and…
The response of a position-sensitive Li-glass scintillator detector being developed for thermal-neutron detection with 6 mm position resolution has been investigated using collimated beams of thermal neutrons. The detector was moved…
One of the critical aspects for the accurate determination of neutron capture cross sections when combining time-of-flight and total energy detector techniques is the characterization and control of systematic uncertainties associated to…
Although for large area detectors it is crucial to find an alternative to detect thermal neutrons because of the 3He shortage, this is not the case for small area detectors. Neutron scattering science is still growing its instruments' power…
We report on a new technique of a Multi-Cathode Counter (MCC) developed to search for hidden photon (HP) cold dark matter (CDM) with a mass from 5 to 500 eV. The method suggested in the assumption that hidden photons of the mass greater…
A new measurement of the $^{235}$U(n,f) cross section was performed at the neutron time-of-flight facility n_TOF at CERN. The experiment focused on neutron energies from 20 MeV to several hundred MeV, and was normalized to neutron…
We demonstrate position and energy-resolved phonon-mediated detection of particle interactions in a silicon substrate instrumented with an array of microwave kinetic inductance detectors (MKIDs). The relative magnitude and delay of the…