Related papers: Magnetic shield of PMT used in DAMPE electromagnet…

200 papers

We present a detailed characterisation of the new Hamamatsu R12199-01 HA MOD 3-inch photomultiplier tube (PMT) which is under consideration for the use in segmented optical modules of deep-ice neutrino detectors at the South Pole. Because…

Instrumentation and Detectors · Physics 2019-03-20 M. A. Unland Elorrieta , L. Classen , J. Reubelt , S. Schmiemann , J. Schneider , A. Kappes

The aim of this paper is to fully characterize the new multi-anode photomultiplier tube R11265-103-M64, produced by Hamamatsu. Its high effective active area (77%), its pixel size, the low dark signal rate and the capability to detect…

Instrumentation and Detectors · Physics 2015-06-19 L. Cadamuro , M. Calvi , L. Cassina , A. Giachero , C. Gotti , B. Khanji , M. Maino , C. Matteuzzi , G. Pessina

We report the results of a characterization study of several types of cryogenic photomultipliers manufactured by Hamamatsu Photonics and intended for operation in liquid Ar conditions, namely: compact 2-inch R6041-506MOD tubes, 3-inch…

Instrumentation and Methods for Astrophysics · Physics 2017-05-24 A. Bondar , A. Buzulutskov , A. Dolgov , E. Frolov , V. Nosov , L. Shekhtman , A. Sokolov

We report on the progress in characterization of the Hamamatsu model R11410-21 Photomultiplier tubes (PMTs) for XENON1T dark matter experiment. The absolute quantum efficiency (QE) of the PMT was measured at low temperatures down to -110…

Instrumentation and Methods for Astrophysics · Physics 2019-08-13 Alexey Lyashenko

Cherenkov-type particle detectors or scintillators use as a fundamental element photomultiplier tubes, whose efficiency decreases when subjected to the Earth's magnetic field. This work develops a geomagnetic field compensation system based…

Photomultiplier tubes (PMTs) are essential in xenon detectors like PandaX, LZ, and XENON experiments for dark matter searches and neutrino properties measurement. To minimize PMT-induced backgrounds, stringent requirements on PMT…

Thin flexible sheets of high-permeability FINEMET foils encased in thin plastic layers have been used to shield various types of 20-cm-diameter photomultiplier tubes from ambient magnetic fields. In the presence of the Earth's magnetic…

Instrumentation and Detectors · Physics 2015-06-17 P. DeVore , D. Escontrias , T. Koblesky , C. J. Lin , D. W. Liu , K. B. Luk , J. Ngan , J. C. Peng , C. Polly , J. Roloff , H. Steiner , S. Wang , J. Wong , M. Yeh

We compared the performance of a SiPM array and a PMT in a laboratory setting using a single 5.08x5.08-cm cylindrical sodium iodide scintillating crystal. Photomultiplier tubes (PMTs) are the most commonly used device to monitor…

Instrumentation and Detectors · Physics 2020-01-23 Tyana Stiegler , Kareem Kazkaz , Erik Swanberg , Vladimir Mozin

We investigated the use of Hamamatsu fine-mesh photomultiplier tube assemblies H6152-70 and H6614-70 with regards to their gain and timing resolution in magnetic fields up to 1.9 T. Our results show that the H6614-70 assembly can operate…

Instrumentation and Detectors · Physics 2016-06-22 V. Sulkosky , L. Allison , C. Barber , T. Cao , Y. Ilieva , K. Jin , G. Kalicy , K. Park , N. Ton , X. Zheng

We successfully developed a new photomultiplier tube (PMT) with a three-inch diameter, convex-shaped photocathode, R13111. Its prominent features include good performance and ultra-low radioactivity. The convex-shaped photocathode realized…

Due to the progressive increase in size of the latest Cherenkov-type detectors, it is becoming increasingly important to design a suitable compensation system based on coils of the Earth's magnetic field to ensure the correct operation of…

It is common practice to test the optical properties of photomultiplier tubes (PMTs) by illuminating the entire photocathode region from the front at once and measuring the average performance. However, for optimal utilisation of the PMT…

Instrumentation and Detectors · Physics 2021-12-03 M. A. Unland Elorrieta , R. S. Busse , L. Classen , A. Kappes

We describe measurements of gain, dark current, and quantum efficiency obtained while cooling a Hamamatsu R5912-02-MOD photomultiplier tube from room temperature to 29 K. We found that the PMT operated normally down to 29 K, with a reduced…

Astrophysics · Physics 2008-11-26 James A. Nikkel , W. Hugh Lippincott , Daniel N. McKinsey

The PandaX-4T liquid xenon detector uses Hamamatsu 3-inch R11410-23 photomultiplier tubes (PMTs) as the light sensors for ultra-low radioactivity, high quantum efficiency, and long-term stability at cryogenic temperature. Each PMT was…

High Energy Physics - Experiment · Physics 2025-06-02 Binbin Yan , Di Huang , Jianglai Liu , Xiaoying Lu , Anqing Wan , Mengjiao Xiao

The H12700 is a novel 64-channel 52 $\times$ 52 mm$^2$ square Multi-Anode PhotoMultiplier Tube (MaPMT) produced by Hamamatsu. Its characteristics make this device suitable for high energy physics applications, such as in Ring Imaging…

Instrumentation and Detectors · Physics 2015-10-06 Marta Calvi , Paolo Carniti , Lorenzo Cassina , Claudio Gotti , Matteo Maino , Clara Matteuzzi , Gianluigi Pessina

Hamamatsu photomultiplier tubes (PMT) and various PMT window materials were exposed to gamma irradiation. Tests were performed with absorbed doses of 1 krad and 120 krad. Initial recommendations on PMT types to use in the BTeV…

Instrumentation and Detectors · Physics 2007-05-23 A. Borisevich , V. Dormenev , G. Drobychev , A. Fyodorov , M. Korzhik , Y. Kubota , A. Lobko , A. Lopatik , O. Missevitch , V. Moroz

Photomultiplier tubes (PMTs) are traditionally an integral part of large underground experiments as they measure the light emission from particle interactions within the enclosed detection media. The BUTTON experiment will utilise around…

To address the Reactor Antineutrino Anomaly (RAA) observed in neutrino experiments, the Reactor Experiment for Neutrino and Exotics (RENE) has been initiated using a liquid scintillation detector. In this study, we investigate the…

Since the early days of experimental particle physics photomultipliers (PMTs) have played an important role in the detector design. Thanks to their capability of fast photon counting, PMTs are extensively used in the new-generation of…

Instrumentation and Detectors · Physics 2016-08-24 C. Bozza , T. Chiarusi , M. Costa , F. Di Capua , V. Kulikovskiy , R. Mele , P. Migliozzi , C. M. Mollo , C. Pellegrino , G. Riccobene , D. Vivolo

We report device level damping measurements using spin-torque driven ferromagnetic resonance on perpendicular magnetic random-access memory (MRAM) cells. It is shown that thermal agitation enhances the apparent damping for cells smaller…

Mesoscale and Nanoscale Physics · Physics 2024-07-31 H. J. Richter , G. Mihajlović , R. V. Chopdekar , W. Jung , J. Gibbons , N. D. Melendez , M. K. Grobis , T. S. Santos