English
Related papers

Related papers: High Resolution Gamma Ray Detection in a Dual Phas…

200 papers

The technique to realize 3D position sensitivity in a two-phase xenon time projection chamber (XeTPC) for dark matter search is described. Results from a prototype detector (XENON3) are presented.

In the past decade, dual-phase xenon time projection chambers (Xe-TPCs) have emerged as some of the most powerful detectors in the fields of astroparticle physics and rare-event searches. Developed primarily towards the direct detection of…

Instrumentation and Detectors · Physics 2024-02-05 Laura Baudis

Dual-phase time projection chambers (TPCs) filled with the liquid noble gas xenon (LXe) are currently the most sensitive detectors searching for interactions of WIMP dark matter in a laboratory-based experiment. This is achieved by…

Instrumentation and Methods for Astrophysics · Physics 2014-08-08 Marc Schumann

The dual-phase xenon time projection chamber (TPC) is a leading detector technology in rare event searches for dark matter and neutrino physics. The success of this type of detector technology relies on its capability to detect both primary…

Instrumentation and Detectors · Physics 2022-02-16 Yuehuan Wei , Jianyang Qi , Evan Shockley , Haiwen Xu , Kaixuan Ni

The need for precise characterization of dual-phase xenon detectors has grown as the technology has matured into a state of high efficacy for rare event searches. The Michigan Xenon detector was constructed to study the microphysics of…

Instrumentation and Detectors · Physics 2016-08-25 S. Stephenson , J. Haefner , Q. Lin , K. Ni , K. Pushkin , R. Raymond , M. Schubnell , N. Shutty , G. Tarlé , C. Weaverdyck , W. Lorenzon

Dual phase time projection chamber using liquid xenon as target material is one of most successful detectors for dark matter direct search, and has improved the sensitivities of searching for weakly interacting massive particles by almost…

Instrumentation and Detectors · Physics 2021-09-01 Qing Lin

Xenon dual-phase time projection chambers designed to search for Weakly Interacting Massive Particles have so far shown a relative energy resolution which degrades with energy above $\sim$200 keV due to the saturation effects. This has…

Instrumentation and Detectors · Physics 2020-09-10 E. Aprile , J. Aalbers , F. Agostini , M. Alfonsi , L. Althueser , F. D. Amaro , V. C. Antochi , E. Angelino , J. Angevaare , F. Arneodo , D. Barge , L. Baudis , B. Bauermeister , L. Bellagamba , M. L. Benabderrahmane , T. Berger , P. A. Breur , A. Brown , E. Brown , S. Bruenner , G. Bruno , R. Budnik , C. Capelli , J. M. R. Cardoso , D. Cichon , B. Cimmino , M. Clark , D. Coderre , A. P. Colijn , J. Conrad , J. P. Cussonneau , M. P. Decowski , A. Depoian P. Di Gangi A. Di Giovanni R. Di Stefano , S. Diglio , A. Elykov , G. Eurin , A. D. Ferella , W. Fulgione , P. Gaemers , R. Gaior , A. Gallo Rosso , M. Galloway , F. Gao , M. Garbini , L. Grandi , C. Hasterok , C. Hils , K. Hiraide , L. Hoetzsch , E. Hogenbirk , J. Howlett , M. Iacovacci , Y. Itow , F. Joerg , N. Kato , S. Kazama , M. Kobayashi , G. Koltman , A. Kopec , H. Landsman , R. F. Lang , L. Levinson , Q. Lin , S. Lindemann , M. Lindner , F. Lombardi , J. A. M. Lopes , E. López Fune , C. Macolino , J. Mahlstedt , L. Manenti , A. Manfredini , F. Marignetti , T. Marrodán Undagoitia , K. Martens , J. Masbou , D. Masson , S. Mastroianni , M. Messina , K. Miuchi , A. Molinario , K. Morå , S. Moriyama , Y. Mosbacher , M. Murra , J. Naganoma , K. Ni , U. Oberlack , K. Odgers , J. Palacio , B. Pelssers , R. Peres , J. Pienaar , V. Pizzella , G. Plante J. Qin , H. Qiu , D. Ramírez García , S. Reichard , A. Rocchetti , N. Rupp , J. M. F. dos Santos , G. Sartorelli , N. Šarčević , M. Scheibelhut , S. Schindler , J. Schreiner , D. Schulte , M. Schumann , L. Scotto Lavina , M. Selvi , F. Semeria , P. Shagin , E. Shockley , M. Silva , H. Simgen , A. Takeda , C. Therreau , D. Thers , F. Toschi , G. Trinchero , C. Tunnell , M. Vargas , G. Volta , O. Wack , H. Wang , Y. Wei , C. Weinheimer , M. Weiss Xu , D. Wenz , C. Wittweg , J. Wulf , Z. Xu , M. Yamashita , J. Ye , G. Zavattini , Y. Zhang , T. Zhu , J. P. Zopounidis

Liquid xenon time projection chambers offer a homogeneous detection medium with excellent intrinsic energy resolution, fast scintillation, and true three-dimensional position sensitivity, making them an attractive alternative to…

Instrumentation and Detectors · Physics 2026-03-30 B. Li , Y. Ma , K. Ni

Dual phase xenon time projection chambers (TPCs) detect both the scintillation photons and ionization electrons created by energy depositions within the liquid xenon (LXe) volume. The electrons are extracted from the interaction site…

Instrumentation and Detectors · Physics 2025-02-24 Jianyang Qi , Kaixuan Ni , Haiwen Xu , Yue Ma , Yuechen Liu

The idea of a hermetic quartz chamber in a dual-phase xenon time projection chamber (TPC) has the potential to improve the detector sensitivity for direct dark matter searches in the future. A major challenge facing TPC detectors in future…

We have been developing a high-pressure xenon gas time projection chamber (TPC) to search for neutrinoless double beta ($0\nu\beta\beta$) decay of $^{136}$Xe. The unique feature of this TPC is in the detection part of ionization electrons,…

A high-pressure xenon gas time projection chamber, with a unique cellular readout structure based on electroluminescence, has been developed for a large-scale neutrinoless double-beta decay search. In order to evaluate the detector…

The design and performance of a 1.2 liter liquid xenon chamber equipped with 7 two-inch photomultiplier tubes, with the purpose of studying the scintillation response of xenon to gamma-rays and neutrons, is described. Measurements with…

We studied the application of statistical reconstruction algorithms, namely maximum likelihood and least squares methods, to the problem of event reconstruction in a dual phase liquid xenon detector. An iterative method was developed for…

We present the design, data and results from the NEXT prototype for Double Beta and Dark Matter (NEXT-DBDM) detector, a high-pressure gaseous natural xenon electroluminescent time projection chamber (TPC) that was built at the Lawrence…

NEXT-100 is a high-pressure xenon time projection chamber with electroluminescent amplification, designed to operate with up to approximately 70.5 kg at 13.5 bar. It is the most recent detector developed by the NEXT collaboration to search…

Instrumentation and Detectors · Physics 2026-01-13 NEXT Collaboration , M. Pérez Maneiro , M. Martínez-Vara , S. Torelli , G. Martínez-Lema , P. Novella , J. A. Hernando Morata , J. J. Gómez-Cadenas , C. Adams , H. Almazán , V. Álvarez , A. I. Aranburu , L. Arazi , I. J. Arnquist , F. Auria-Luna , S. Ayet , Y. Ayyad , C. D. R. Azevedo , K. Bailey , F. Ballester , J. E. Barcelon , M. del Barrio-Torregrosa , A. Bayo , J. M. Benlloch-Rodríguez , F. I. G. M. Borges , A. Brodoline , N. Byrnes , A. Castillo , E. Church , L. Cid , M. Cid , X. Cid , C. A. N. Conde , C. Cortes-Parra , F. P. Cossío , R. Coupe , E. Dey , P. Dietz , C. Echeverria , M. Elorza , R. Esteve , R. Felkai , L. M. P. Fernandes , P. Ferrario , F. W. Foss , Z. Freixa , J. García-Barrena , J. W. R. Grocott , R. Guenette , J. Hauptman , C. A. O. Henriques , P. Herrero-Gómez , V. Herrero , C. Hervés Carrete , Y. Ifergan , A. F. B. Isabel , B. J. P. Jones , F. Kellerer , L. Larizgoitia , A. Larumbe , F. Lopez , N. López-March , R. Madigan , R. D. P. Mano , A. Marauri , A. P. Marques , J. Martín-Albo , A. Martínez , R. L. Miller , K. Mistry , J. Molina-Canteras , F. Monrabal , C. M. B. Monteiro , F. J. Mora , K. E. Navarro , D. R. Nygren , E. Oblak , J. Palacio , B. Palmeiro , I. Parmaksiz , A. Pazos , J. Pelegrin , M. Querol , J. Renner , I. Rivilla , C. Rogero , L. Rogers , B. Romeo , C. Romo-Luque , E. Ruiz-Chóliz , P. Saharia , F. P. Santos , J. M. F. dos Santos , M. Seemann , I. Shomroni , A. L. M. Silva , P. A. O. C. Silva , A. Simón , S. R. Soleti , M. Sorel , J. Soto-Oton , J. M. R. Teixeira , S. Teruel-Pardo , J. F. Toledo , C. Tonnelé , J. Torrent , A. Trettin , P. R. G. Valle , M. Vanga , P. Vázquez Cabaleiro , J. F. C. A. Veloso , J. D. Villamil , J. Waiton , A. Yubero-Navarro

The next-generation of $0\nu\beta\beta$ searches are targeting half-life sensitivities towards 10$^{27}$--10$^{28}$ years. Gaseous xenon time projection chamber (GXeTPC) detectors may be able to meet this challenge due to their excellent…

Instrumentation and Detectors · Physics 2026-03-19 K. Mistry , Y. Mei , D. R. Nygren

We report on the development of a large-volume, wide field-of-view time projection chamber (TPC) for X-ray polarimetry, featuring a triple-GEM amplification stage and optical readout. Originally developed within the CYGNO program for…

Dual-phase xenon time projection chamber (TPC) detectors offer heightened sensitivities for dark matter detection across a spectrum of particle masses. To broaden their capability to low-mass dark matter interactions, we investigated the…

Xenon time projection chambers (TPCs) have become a well-established detection technology for neutrinoless double beta decay searches in $^{136}$Xe. I discuss the motivations for this choice. I describe the status and prospects of both…

Instrumentation and Detectors · Physics 2019-04-16 Michel Sorel
‹ Prev 1 2 3 10 Next ›