Magneto-optical traps are central to atomic and molecular quantum technologies and precision tests of fundamental physics, where both sensitivity and bandwidth scale strongly with atom number and loading rate. We demonstrate that employing…

Magnetic Detection Electrical Impedance Tomography is a novel technique that could enable non-invasive imaging of fast neural activity in the brain. However, commercial magnetometers are not suited to its technical requirements.…

Medical Physics · Physics 2024-12-19 Kai Mason , Florencia Maurino-Alperovich , Kirill Aristovich , David Holder

In this paper, we propose a new paradigm for atom interferometry and demonstrate that there exists a universal set of atom optic components for inertial sensing. These components constitute gates with which we carry out quantum operations…

Quantum Physics · Physics 2024-10-24 Catie LeDesma , Kendall Mehling , John Drew Wilson , Marco Nicotra , Murray Holland

We demonstrate the possibility of dynamic imaging of magnetic fields using electromagnetically induced transparency in an atomic gas. As an experimental demonstration we employ an atomic Rb gas confined in a glass cell to image the…

Quantum Physics · Physics 2010-09-29 Eugeniy E. Mikhailov , I. Novikova , M. D. Havey , F. A. Narducci

Atomic magnetometers have very high absolute precision and sensitivity to magnetic fields but suffer from a fundamental problem: the vectorial or tensorial interaction of light with atoms leads to "dead zones", certain orientations of…

Atomic Physics · Physics 2015-05-14 A. Ben-Kish , M. V. Romalis

We consider various methods and techniques for measuring electron magnetization and susceptibility, which are used in experimental condensed matter physics. The list of considered methods for macroscopic measurements includes…

Materials Science · Physics 2023-02-20 V. M. Pudalov

Atomic interferometers measure forces and acceleration with exceptional precision. The conventional approach to atomic interferometry is to launch an atomic cloud into a ballistic trajectory and perform the wave-packet splitting in momentum…

Quantum Physics · Physics 2024-02-23 Jonathan Nemirovsky , Rafi Weill , Ilan Meltzer , Yoav Sagi

An atom interferometer using a Bose-Einstein condensate of $^{87}$Rb atoms is utilized for the measurement of magnetic field gradients. Composite optical pulses are used to construct a spatially symmetric Mach-Zehnder geometry. Using a…

Ultra-cold atoms can be manipulated using microfabricated devices known as atom chips. These have significant potential for applications in sensing, metrology and quantum information processing. To date, the chips are loaded by transfer of…

We present a novel approach allowing an optically pumped magnetometer (OPM) to be operated within Earth's magnetic field as a vector magnetometer whose sensitive axis can be freely defined. This approach enables the measurement of any…

Instrumentation and Detectors · Physics 2024-08-20 Thomas Schönau , Theo Scholtes , Florian Wittkämper , Alexander Sekels , Stefan Hiebel , Gregor Oelsner , Ronny Stolz

Recent studies have highlighted the frequent applications of structured light modes in optically pumped atomic magnetometers. In this work, we theoretically explore how a Poincar\'e beam probes an optically polarized atomic medium.…

Atomic Physics · Physics 2025-06-23 S. Ramakrishna , S. Fritzsche

We present an experimental scheme performing scalar magnetometry based on the fitting of Rb D$_2$ line spectra recorded by derivative selective reflection spectroscopy from an optical nanometric-thick cell. To demonstrate its efficiency,…

In this work, we report the development of a rubidium-based single-beam scalar optically pumped magnetometer (OPM) and demonstrate its application in measuring human cardiac magnetic fields in an unshielded environment. The developed…

Statistical Mechanics · Physics 2026-02-17 Kushal Patel , Kesavaraja C , Pranab Dutta , Korak Biswas

Multi-loop matter-wave interferometers are essential in quantum sensing to measure the derivatives of physical quantities in time or space. Because multi-loop interferometers require multiple reflections, imperfections of the matter-wave…

Atomic Physics · Physics 2020-11-24 L. A. Sidorenkov , R. Gautier , M. Altorio , R. Geiger , A. Landragin

We consider resonant vortices around nodal points of the wavefunction in electron transport through a mesoscopic device. With a suitable choice of the device geometry, the dominating role is played by single vortices of a preferred…

Mesoscale and Nanoscale Physics · Physics 2008-02-03 P. Exner , P. Seba , A. F. Sadreev , P. Streda , P. Feher

We report on the design and performance of a highly sensitive combined $^3$He/Cs magnetometer for the absolute measurement of magnetic fields. The magnetometer relies on the magnetometric detection of the free spin precession of nuclear…

The atomic population trapped in uncoupled atomic states is a limiting factor for processes based on laser-atom interaction. The use of repump laser, bi-chromatic field, and vector magnetic field are explored in degenerate as well as…

Atomic Physics · Physics 2023-04-28 Swarupananda Pradhan , Sudip mandal

We analyze magnetometry using an optically levitated nanodiamond. We consider a configuration where a magnetic field gradient couples the mechanical oscillation of the diamond with its spin degree of freedom provided by a Nitrogen vacancy…

Quantum Physics · Physics 2017-08-09 Pardeep Kumar , M. Bhattacharya

Noise measurements have been carried out in the LISA bandwidth (0.1 mHz to 100 mHz) to characterize an all-optical atomic magnetometer based on nonlinear magneto-optical rotation. This was done in order to assess if the technology can be…

Instrumentation and Detectors · Physics 2015-01-19 I. Mateos , B. Patton , E. Zhivun , D. Budker , D. Wurm , J. Ramos-Castro

Magnetic field imaging is a valuable resource for signal source localization and characterization. This work reports an optically pumped magnetometer (OPM) based on the free-induction-decay (FID) protocol, that implements microfabricated…