Related papers: Cryogenic Calibration Setup for Broadband Complex …
We develop Johnson noise thermometry applicable to mesoscopic devices with variable source impedance with high bandwidth for fast data acquisition. By implementing differential noise measurement and two-stage impedance matching, we…
The low frequency complex impedance of a high resistivity 92 {\mu}{\Omega} cm and 100 nm thick TiN superconducting film has been measured via the transmission of several high sensitivity GHz microresonators, down to Tc/50. The temperature…
In the past decade, several neutron reflectometry methods for determining the modulus and phase of the complex reflection coefficient of an unknown multilayer thin film have been worked out among which the method of variation of…
Recent years have seen considerable research success in the field of dynamic homogenization which seeks to define frequency dependent effective properties for heterogeneous composites for the purpose of studying wave propagation. There is…
Efficient and accurate measurement of the bi-directional reflectance distribution function (BRDF) plays a key role in high quality image rendering and physically accurate sensor simulation. However, obtaining the reflectance properties of a…
We consider the problem of estimating the temperature $ T $ of a very cold equilibrium sample. The temperature estimates are drawn from measurements performed on a quantum probe strongly coupled to it. We model this scenario by resorting to…
Experimental results for the reflection coefficient of shock-compressed dense Xenon plasmas at pressures of 1.6 - 17 GPa and temperatures around 30 000 K using a laser beam with \lambda = 1.06 10^-6 m are compared with calculations based on…
We experimentally investigate the Bragg reflection of light at one-dimensionally ordered atomic structures by using cold atoms trapped in a laser standing wave. By a fine tuning of the periodicity, we reach the regime of multiple reflection…
A fundamental pursuit of microwave metrology is the determination of the characteristic impedance profile of microwave systems. Among other methods, this can be practically achieved by means of time-domain reflectometry (TDR) that measures…
Silicon photonic ring resonator thermometers have been shown to provide temperature measurements with a 10 mK accuracy. In this work we identify and quantify the intrinsic on-chip impairments that may limit further improvement in…
In many cases beam coupling impedances or wake fields are calculated with computer simulator such as CST Studio Suite, GdfidL Electromagnetic Field Simulator and so on. But evaluation with the stretched-wire method is still very useful by…
A robust cryogenic infrastructure in form of a wired, thermally optimized dilution refrigerator is essential for present and future solid-state based quantum processors. Here, we engineer an extensible cryogenic setup, which minimizes…
At the ultra-thin limit below 20 nm, a film's electrical conductivity, thermal conductivity, or thermoelectricity depends heavily on its thickness. In most studies, each sample is fabricated one at a time, potentially leading to…
We studied noise properties of microwave signals transmitted through the cryogenic resonator. The experiments were performed with the 11.342 GHz sapphire loaded cavity resonator cooled to 6.2 K. Based on the measured transmission…
Noise filtering is an essential part for measurement of quantum phenomena at extremely low temperatures. Here, we present the design of a filter which can be installed in space constrained cryogenic environment containing a large number of…
Superconducting resonators with high quality factors are extremely sensitive detectors of the complex impedance of materials and devices coupled to them. This capability has been used to measure losses in multiple different materials and,…
A densely packed granular system is an example of an out-of-equilibrium system in the jammed state. It has been a longstanding problem to determine whether this class of systems can be described by concepts arising from equilibrium…
An in-house Seebeck coefficient measurement system has been developed which can measure the thermoemf (Seebeck coefficient) of the sample, under large temperature difference, in the temperature range 300-600 K. Unlike majority of reported…
We developed an impedance bridge that operates at cryogenic temperatures (down to 60 mK) and in perpendicular magnetic fields up to at least 12 T. This is achieved by mounting a GaAs HEMT amplifier perpendicular to a printed circuit board…
We have embedded an AlGaAs/GaAs based, gated 2D hole system (2DHS) into an impedance transformer $LC$ circuit, and show that by using radio-frequency reflectometry it is possible to perform sensitive, large bandwidth, electrical resistance…