Related papers: Cryogenic Calibration Setup for Broadband Complex …
This manuscript reports a set of acceleration measurements in the frequency range from 0 to 50 kHz performed at the mixing chamber plate (2 axes) and the top flange (3 axes) of a cryogen-free dilution refrigerator. Various configurations of…
An experimental setup for determining the electrical resistivity of several types of thermoelectric materials over the temperature range 20 < T < 550 C is described in detail. One resistivity measurement during temperature cycling is also…
Spectrometers based on high-finesse optical cavities have proven to be powerful tools for applied and fundamental studies. Extending this technology to the deep cryogenic regime is beneficial in many ways: Doppler broadening is reduced,…
The use of low-temperature detectors, such as cryogenic calorimeters, has pioneered the recent advancements in low-energy rare event searches. These detectors provide a low-noise environment essential for the direct detection of dark matter…
We present a measurement and analysis scheme for determining traceable thermodynamic temperature at cryogenic temperatures using Coulomb blockade thermometry. The uncertainty of the electrical measurement is improved by utilizing two…
We entertain the use of light dependent resistors as a viable option as measuring sensors in optics laboratory experiments or classroom demonstrations. The main advantages of theses devices are essentially very low cost, easy handling and…
A coherent, short-length reference arm reflectometer, which utilizes a 76-MHz repetition rate mode-locked fiber laser, was investigated experimentally for long fiber links (> 10 km). The reflectometer combines the advantages of optical…
We describe the design, fabrication, and validation of a cryogenically-compatible quasioptical thermal source designed to be used for characterization of detector arrays. The source is constructed using a graphite-loaded epoxy mixture that…
Calibration refers to the estimation of unknown parameters which are present in computer experiments but not available in physical experiments. An accurate estimation of these parameters is important because it provides a scientific…
The design and performance of a low-noise, modular cryogenic probe, applicable to a wide range of measurements over a broad range of working frequencies, temperatures, and magnetic fields is presented. The design of the probe facilitates…
Using the Cryogenic, High-Accuracy Refraction Measuring System (CHARMS) at NASA's Goddard Space Flight Center, we have measured the absolute refractive index of five specimens taken from a very large boule of Corning 7980 fused silica from…
Cryogenic characterization of transition-edge sensor (TES) bolometers is a time- and labor-intensive process. As new experiments deploy larger and larger arrays of TES bolometers, the testing process will become more of a bottleneck. Thus…
Aligning a microcantilever to an area of interest on a sample is a critical step in many scanning probe microscopy experiments, particularly those carried out on devices and rare, precious samples. We report a series of protocols that…
The detection of spatial or temporal variations in very thin samples has important applications in the biological sciences. For example, cellular membranes exhibit changes in lipid composition and order, which in turn modulate their…
A quasi-optical (QO) test bench was designed, simulated, and calibrated for characterizing S-parameters of devices in the 220-330 GHz (WR-3.4) frequency range, from room temperature down to 4.8 K. The devices were measured through vacuum…
Far-infrared reflectivity studies on the polycrystalline intermetallic compound MgB_2 with a superconducting transition temperature T_c=39 K were performed at temperatures 20 K to 300 K. We observe a significant raise of the…
A high temperature superconducting detector was fabricated to capture the thermal images in room temperature background. The detector was made of YBa2Cu3O7-{\delta} (YBCO) superconducting thin film deposited on an Yttria Stabilized Zirconia…
We introduce a high performance differential dilatometer based on an all-fiber Michelson interferometer at cryogenic temperature with $10^{-10}$ resolution in $\delta L/L$. It resolve the linear thermal expansion coefficient by measuring…
Deviation from perfect conical dispersion in Dirac materials, such as the presence of mass or tilting, enhances control and directionality of electronic transport. To identify these signatures, we analyze the thermal derivative spectra of…
The high quantum efficiencies (QE) of backside illuminated charge coupled devices (CCD) has ushered in the age of the large scale astronomical survey. The QE of these devices can be greater than 90 %, and is dependent upon the operating…