Related papers: Optimum performance investigation of LYSO crystal …
Monte Carlo Simulation (MCS) is a state-of-the-art technique in designing sophisticated apparatus for various applications in science and technology. We adopted MCS based on GEANT (GEometry ANd Tracking) in order to design a simple…
In this study, we propose a fast implementation of a Maximum Likelihood Positioning (MLP) algorithm to estimate the energy and identify the active scintillator pixel in staggered layer scintillation detectors for PET. The staggered layer…
Proportional scintillation counters (PSCs), both single- and dual-phase, can measure the scintillation (S1) and ionization (S2) channels from particle interactions within the detector volume. The signal obtained from these detectors depends…
Nowadays, the current threat of international terrorism is set to a severe level, demanding worldwide enhanced security. Radioactive materials that could be fashioned into a radiation dispersal device typically emit gamma rays, while…
A comprehensive model for explaining scintillation yield in liquid xenon is introduced. We unify various definitions of work function which abound in the literature and incorporate all available data on electron recoil scintillation yield.…
Opaque scintillators are designed to have a short scattering length such that scintillation photons are probabilistically confined to a small region of space about their origin. The benefit of this feature is that information on the…
A novel method of hit time and hit position reconstruction in scintillator detectors is described. The method is based on comparison of detector signals with results stored in a library of synchronized model signals registered for a set of…
Time-of-flight (ToF) measurements is a possible alternative to anti-scatter grids in computed tomography (CT). Simulations have shown a possible 75% reduction in the detrimental scattering contribution with a 100 ps FWHM timing resolution.…
The imaging performance of a high-resolution preclinical microPET system employing liquid xenon as the gamma ray detection medium was simulated. The arrangement comprises a ring of detectors consisting of trapezoidal LXe time projection…
We present the analysis of photospheric emission for a set of hydrodynamic simulations of long duration gamma-ray burst jets from massive compact stars. The results are obtained by using the Monte Carlo Radiation Transfer code (MCRaT) to…
The TT-PET collaboration is developing a small animal TOF-PET scanner based on silicon detectors featuring 30 ps RMS time resolution and intended to be inserted in an existing MRI scanner. The TT-PET scanner makes use of a stack of layers…
Creating and maintaining computer readable geometries for use in Monte Carlo Radiation Transport (MCRT) simulations is an error-prone and time-consuming task. Simulating a system often requires geometry from different sources and modelling…
The combination of plastic scintillators with Silicon Photo-Multipliers (SiPMs) is widely used for detecting radiation in high-energy astrophysics, particle physics, neutrino physics, or medical physics. An example of application for this…
Plastic scintillators are widely used in particle detectors when precise timing information is required. As a basis for comparing different detectors we use such a characteristic as the time resolution per 1MeV detected energy, i.e. the…
Results from the simulations of a Compton gamma camera based on compact configuration of detectors consisting in two detection modules, each of them having two stages of high-resolution position- and energy-sensitive radiation detectors…
We present the design and optimization of a Tomographic Gamma Scanning (TGS) collimator based on Monte Carlo simulations using MCNP5 computer code. In these simulations, an accurate Monte Carlo model of TGS was built and the collimator…
In the context of particle therapy monitoring, we are developing a gamma-ray detector to determine the ion range in vivo from the measurement of particle time-of-flight. For this application, a beam monitor capable to tag in time the…
This paper presents the design and optimization of a LYSO crystal electromagnetic calorimeter (ECAL) for the DarkSHINE experiment, which aims to search for dark photons as potential mediators of dark forces. The ECAL design was evaluated…
Monte Carlo simulations are a crucial tool for the analysis and prediction of various background components in liquid xenon (LXe) detectors. With improving shielding in new experiments, the simulation of external backgrounds, such as…
This study presents a Monte Carlo simulation tool for modeling the transportation processes of thermal electrons in noble liquids, specifically focusing on liquid argon and liquid xenon. The study aims to elucidate the microscopical…