English
Related papers

Related papers: Study of gamma ray response of R404A superheated d…

200 papers

R-134a (C2H2F4) is a low cost, easily available and chlorine free refrigerant, which in its superheated state can be used as an efficient neutron detector. Due to its high solubility in water the R-134a based superheated droplet detectors…

Instrumentation and Detectors · Physics 2014-03-28 Prasanna Kumar Mondal , Rupa Sarkar , Barun Kumar Chatterjee

Superheated drop detector (SDD) consisting of drops of superheated liquid of halocarbon is irradiated to neutrons and gamma-rays from 252Cf fission neutron source and 137Cs gamma source separately. The analysis of pulse height of the…

Instrumentation and Detectors · Physics 2014-11-21 Mala Das , S Seth , S Saha , S Bhattacharya , P Bhattacharjee

Superheated Droplet Detectors (SDDs) are becoming commonplace in neutron personnel dosimetry. Their total insensitivity to minimum ionizing radiation (while responsive to nuclear recoils of energies ~ few keV), together with their low cost,…

Astrophysics · Physics 2008-02-03 J. I. Collar , T. A. Girard , D. Limagne , G. Waysand

The bubble nucleation process in superheated droplet detector (SDD) is associated with the emission of an acoustic pulse that can be detected by an acoustic sensor. We have studied the neutron and gamma-ray induced nucleation events in a…

Instrumentation and Detectors · Physics 2014-04-01 Prasanna Kumar Mondal , Susnata Seth , Mala Das , Pijushpani Bhattacharjee

DD and DT reaction rates may be compared to determine plasma temperatures in the 10--200 eV range. Distinguishing neutrons from these two reactions is difficult when yields are low or unpredictable. Time of flight methods fail if the source…

Instrumentation and Detectors · Physics 2014-06-11 J. I. Katz

It is shown that under realistic background considerations, an improvement in Cold Dark Matter sensitivity of several orders of magnitude is expected from a detector based on superheated liquid droplets. Such devices are totally insensitive…

Astrophysics · Physics 2010-01-06 J. I. Collar

Two-dimensional solid state gaseous detector for thermal and cold neutrons is created. The detector has active area of 128 x 128 $mm^2$, $^{10}B$ neutron converter, and gas chamber with thin windows. The resistive charge-division readout is…

Instrumentation and Detectors · Physics 2017-04-05 S Potashev , Yu Burmistrov , A Drachev , S Karaevsky , E Konobeevski , S Zuyev

Energy calibration of superheated droplet detector is discussed in terms of the effective recoil nucleus threshold energy and the reduced superheat. This provides a universal energy calibration curve valid for different liquids used in this…

Instrumentation and Detectors · Physics 2017-07-26 Mala Das , Susnata Seth

Superheated drops are known to detect neutrons through the nucleation caused by the recoil nuclei produced by the interactions of neutrons with the atoms constituting the superheated liquid molecule. A novel method of finding the neutron…

Instrumentation and Detectors · Physics 2009-11-06 Mala Das , B. K. Chatterjee , B. Roy , S. C. Roy

Prototype of gamma ray detector based on Micro Pixel Avalanche Photodiodes (MAPD) with high pixel density 15000 pixel/$mm^2$, optically coupled to Lutetium Fine Silicate (LFS) scintillator has been developed. The detection performance…

Instrumentation and Detectors · Physics 2013-02-11 E. Guliyev , F. Ahmadov , G. Ahmadov , A. Sadigov , Z. Sadigov , N. Anfimov , Z. Krumshtein , A. Olshevski , V. Shvetsov , V. Zhezher , R. Madatov

We present results of systematic studies of the radiation response of superheated liquid droplet detectors, which are used in the PICASSO dark matter search experiment. This detection technique is based on the phase transitions of…

We discuss the operation principle of a detector based on superheated droplets of Freon-12 and its feasibility for the search of weakly interacting cold dark matter particles. In particular we are interested in a neutralino search…

High Energy Physics - Experiment · Physics 2009-10-28 L. A. Hamel , L. Lessard , L. Rainville , B. Sur , V. Zacek

It has been reported so far that superheated drop detector made of R-12 at room temperature are sensitive to neutrons yet insensitive to photons. This property makes its use as one of the most useful neutron dosimeter. The photon…

Instrumentation and Detectors · Physics 2009-11-06 B. Roy , Mala Das , S. C. Roy , B. K. Chatterjee

Detectors based on liquid or gas xenon have been used and are in use for a number of applications, in particular for the detection of gamma rays. Xenon is a well-suited medium for gamma spectroscopy thanks to its high atomic number and,…

Instrumentation and Detectors · Physics 2013-09-10 F. Resnati

We discuss how detection of gamma-ray emission from the decay of r-process nuclei can improve our understanding of r-process nucleosynthesis. We find that a gamma-ray detector with a sensitivity of 10**(-7)/cm**2/s at 100-700 keV may detect…

Astrophysics · Physics 2009-10-30 Y. -Z. Qian , P. Vogel , G. J. Wasserburg

We have characterized two state-of-the-art solid-state photomultipliers, one by SensL, the other by Hamamatsu, coupled to scintillators by Saint-Gobain Crystals in the -25 to 50 degrees C temperature range. At room temperature, the energy…

Instrumentation and Detectors · Physics 2011-03-28 Clarisse Tur , Vladimir Solovyev , Jeremy Flamanc

The combined measurement of dark matter interactions with different superheated liquids has recently been suggested as a cross-correlation technique in identifying WIMP candidates. We describe the fabrication of high concentration…

Instrumentation and Detectors · Physics 2015-06-17 M. Felizardo , T. Morlat , J. G. Marques , A. R. Ramos , TA Girard , A. C. Fernandes , A. Kling , I. Lazaro , R. C. Martins , J. Puibasset

We have devised a technique for measuring some of the most important nuclear reactions in stars which we expect to provide considerable improvement over previous experiments. Adapting ideas from dark matter search experiments with bubble…

Instrumentation and Methods for Astrophysics · Physics 2015-06-12 C. Ugalde , B. DiGiovine , D. Henderson , R. J. Holt , K. E. Rehm , A. Sonnenschein , A. Robinson , R. Raut , G. Rusev , A. P. Tonchev

A dual-operation mode SNSPD is proposed. In the conventional Geiger mode, the sensor operates at temperatures well below the critical temperature, Tc, working as an event counter without sensitivity to the number of photons impinging the…

A CubeSat with a prototype scintillating detector with a sensitive volume of GAGG crystal is being developed with a possible launch date of 2025. Its purpose is to characterize the background signals that mimic the neutrino interaction that…

‹ Prev 1 2 3 10 Next ›