English
Related papers

Related papers: Microscope Mode Secondary Ion Mass Spectrometry Im…

200 papers

Swift, high resolution CMOS pixel sensors are being developed for the ILC vertex detector, aiming to allow approaching the interaction point very closely. A major issue is the time resolution of the sensors needed to deal with the high…

SOI (Silicon-On-Insulator) pixel sensor is promising technology for developing the high position resolution detector by integrating the small pixels and circuits in the monolithic way. The event driven (trigger mode) SOI based pixel sensor…

We have been developing the X-ray silicon-on-insulator (SOI) pixel sensor called XRPIX for future astrophysical satellites. XRPIX is a monolithic active pixel sensor consisting of a high-resistivity Si sensor, thin SiO$_2$ insulator, and…

Instrumentation and Methods for Astrophysics · Physics 2020-01-29 K. Hagino , K. Negishi , K. Oono , K. Yarita , T. Kohmura , T. G. Tsuru , T. Tanaka , S. Harada , K. Kayama , H. Matsumura , K. Mori , A. Takeda , Y. Nishioka , M. Yukumoto , K. Fukuda , T. Hida , Y. Arai , I. Kurachi , S. Kishimoto

Isochronous mass spectrometry (IMS) in storage rings is a powerful tool for mass measurements of exotic nuclei with very short half-lives down to several tens of microseconds, using a multicomponent secondary beam separated in-flight…

In this paper the efficiency of direct charged particle detection with different Silicon PhotoMultiplier (SiPM) sensors has been measured to be close to 100%. Time resolution of about 20 ps has also been confirmed for sensors with an active…

A commercial, position-sensitive ion detector was used for the first time for the time-of-flight ion-cyclotron resonance detection technique in Penning trap mass spectrometry. In this work, the characteristics of the detector and its…

Nuclear Experiment · Physics 2009-09-10 G. Eitel , M. Block , A. Czasch , M. Dworschak , S. George , O. Jagutzki , J. Ketelaer , J. Ketter , Sz. Nagy , D. Rodriguez , C. Smorra , K. Blaum

Mass spectrometry imaging (MSI) as an analytical tool for bio-molecular and bio-medical research targets, accurate compound localization and identification. In terms of dedicated instrumentation, this translates into the demand for more…

Instrumentation and Detectors · Physics 2013-05-24 Julia H. Jungmann , Ron M. A. Heeren

We propose SOI pixel circuits with a synchronized time memory cell (TMC) for time-of-flight stigmatic imaging mass spectrometry. The circuits simultaneously detect the position and the fine/coarse flight time of an ion for the MALDI-ToF…

Instrumentation and Detectors · Physics 2015-07-28 Kaori Watanabe , Masayuki Ikebe , Youichi Fujita , Yasuo Arai , Hisanao Hazama

Combining gaseous detectors with a high-granularity pixelated charge readout enables experimental applications which otherwise could not be achieved. This includes high-resolution tracking of low-energetic particles, requiring ultra-low…

An emission tomography of laser-induced plasmas employed in the laser induced breakdown spectroscopy (LIBS) requires long signal integration times during which the plasma cannot be considered stationary. To reduce the integration time, it…

Plasma Physics · Physics 2010-08-04 Sergei V. Shabanov , Igor B. Gornushkin

An interpolating two-dimensional X-ray imaging detector based on a single photon counter with gas amplification by GEM (gas electron multiplier) structures is presented. The detector system can be used for time-resolved structure research…

This paper presents some observations and ideas collected during the tests of the SOI sensors, based on the integration type pixels. First, it contains a rough analysis of the Correlated Double Sampling filtering properties with respect to…

While designed primarily for X-ray imaging applications, the Medipix3 ASIC can also be used for charged-particle tracking. In this work, results from a beam test at the CERN SPS with irradiated and non-irradiated sensors are presented and…

One of the key points in designing an integrated sensing and communication (ISAC) system using computational imaging is the division size of imaging pixels. If the size is too small, it leads to a high number of pixels that need processing.…

Signal Processing · Electrical Eng. & Systems 2025-05-13 Xin Tong , Zhaoyang Zhang , Zhaohui Yang , Yu Ge , Henk Wymeersch

Active Pixel Sensor (APS) technology has shown promise for next-generation vertex detectors. This paper discusses the design and testing of two generations of APS chips. Both are arrays of 128 by 128 pixels, each 20 by 20 micro-m. Each…

Nuclear Experiment · Physics 2011-07-19 H. S. Matis , F. Bieser , S. Kleinfelder , G. Rai , F. Retiere , H. G. Ritter , K. Singh , S. E. Wurzel , H. Wieman , E. Yamamoto

CMOS sensors were successfully implemented in the STAR tracker [1]. LHC experiments have shown that efficient b tagging, reconstruction of displaced vertices and identification of disappearing tracks are necessary. An improved vertex…

Instrumentation and Detectors · Physics 2021-05-21 Nicolas T. Fourches , Geraldine Hallais , Charles Renard

Timepix and Timepix3 are hybrid pixel detectors ($256\times 256$ pixels), capable of tracking ionizing particles as isolated clusters of pixels. To efficiently analyze such clusters at potentially high rates, we introduce multiple…

Data Analysis, Statistics and Probability · Physics 2019-11-07 Petr Mánek , Benedikt Bergmann , Petr Burian , Lukáš Meduna , Stanislav Pospíšil , Michal Suk

We report the first characterization results of an optical time-stamping camera based on the Timepix4 chip coupled to a fully depleted optical silicon sensor and fast image intensifier, enabling sub-nanosecond scale, time-resolved imaging…

This paper presents the design and results of detailed tests of a CMOS active pixel chip for charged particle detection with in-pixel charge storage for correlated double sampling and readout in rolling shutter mode at frequencies up to 25…

Instrumentation and Detectors · Physics 2016-11-17 Marco Battaglia , Jean-Marie Bussat , Devis Contarato , Peter Denes , Piero Giubilato , Lindsay E. Glesener

Semiconductor pixel detectors offer features for the detection of radiation which are interesting for particle physics detectors as well as for imaging e.g. in biomedical applications (radiography, autoradiography, protein crystallography)…

High Energy Physics - Experiment · Physics 2009-11-07 Norbert Wermes