English
Related papers

Related papers: Waveform Digitizing for LaBr$_3$/NaI Phoswich Dete…

200 papers

We discuss the performance of a readout system, Fixed Pulse Shape Efficient Readout (FIPSER), to digitize signals from detectors with a fixed pulse shape. In this study we are mainly interested in the readout of fast photon detectors like…

Instrumentation and Detectors · Physics 2016-09-16 Brent Limyansky , Robert Reese , John D. Cressler , Adam Nepomuk Otte , Ignacio Taboada , Cagri Ulusoy

This paper proposes a method for estimating and detecting optical signals in practical photon-counting receivers. There are two important aspects of non-perfect photon-counting receivers, namely, (i) dead time which results in blocking…

Signal Processing · Electrical Eng. & Systems 2024-08-21 Chen Wang , Zhiyong Xu , Jingyuan Wang , Jianhua Li , Weifeng Mou , Huatao Zhu , Jiyong Zhao , Yang Su , Yimin Wang , Ailin Qi

Integrated photonic quantum information processing (QIP) has advanced rapidly due to progress in various nanophotonic platforms. Single photon detectors have been the subject of intense study due to their ubiquity in QIP systems, yet many…

Historically, the discovery and optimization of doped bulk materials has been predominantly developed through an Edisonian approach. While successful and despite the constant progress in fundamental understanding of detector materials…

Materials Science · Physics 2015-08-25 I. V. Khodyuk , S. A. Messina , T. J. Hayden , E. D. Bourret , G. A. Bizarri

The lowering of the energy threshold in the NaI detector is crucial not only for comprehensive validation of DAMA/LIBRA but also for exploring new possibilities in the search for low-mass dark matter and observing coherent elastic…

Instrumentation and Detectors · Physics 2024-06-18 J. J. Choi , C. Ha , E. J. Jeon , K. W. Kim , S. K. Kim , Y. D. Kim , Y. J. Ko , B. C. Koh , H. S. Lee , S. H. Lee , S. M. Lee , B. J. Park , G. H. Yu

Superconducting nanowire single-photon detectors are set apart from other photon counting technologies above all else by their extremely high speed, with few-ten-ps timing resolution, and recovery times $\tau_R\lesssim$10 ns after a…

Instrumentation and Detectors · Physics 2015-06-15 Andrew J. Kerman , Danna Rosenberg , Richard J. Molnar , Eric A. Dauler

Our study introduces innovative methods to address waste reduction and enhance resource efficiency in nuclear cleanup processes. We focus on sustainable nuclear technology, aligning with goals for cleaner production and environmental…

Instrumentation and Detectors · Physics 2025-02-19 Victor V. Golovko

The next generation of very-short-baseline reactor experiments will require compact detectors operating at surface level and close to a nuclear reactor. This paper presents a new detector concept based on a composite solid scintillator…

Detector efficiency determination is essential to correct the measured yields and extract reliable cross sections of particles emitted in nuclear reactions. We investigate the efficiencies for measuring the full energies of light charged…

Instrumentation and Detectors · Physics 2017-02-01 P. Morfouace , W. G. Lynch , M. B. Tsang

We have been developing monolithic active pixel sensors series, named "XRPIX," based on the silicon-on-insulator (SOI) pixel technology, for future X-ray astronomical satellites. The XRPIX series offers high coincidence time resolution…

The detective quantum efficiency (DQE) and normalised noise power spectrum (NNPS) of the Timepix4 hybrid pixel detector in event-driven mode in TEM have been measured at 100 kV and 200 kV. In a raw data readout mode, the zero-frequency DQE…

Hard X-ray photons with energies in the range of hundreds of keV typically undergo Compton scattering when they are incident on a detector. In this process, an incident photon deposits a fraction of its energy at the point of incidence and…

Single photon detectors are key for time-correlated photon counting applications [1] and enable a host of emerging optical quantum information technologies [2]. So far, the leading approach for continuous and efficient single-photon…

Mesoscale and Nanoscale Physics · Physics 2022-01-04 Waqar Khan , Patrick P. Potts , Sebastian Lehmann , Claes Thelander , Kimberly A. Dick , Peter Samuelsson , Ville F. Maisi

Plasmonic enhanced Schottky detectors operating on the basis of the internal photoemission process are becoming an attractive choice for detecting photons with sub bandgap energy. Yet, the quantum efficiency of these detectors appears to be…

Recent advances in photon detectors have resulted in high-density imaging arrays that offer many performance and cost advantages. In particular, the excellent transit time spread of certain devices show promise to provide tangible benefits…

Instrumentation and Detectors · Physics 2009-04-17 Gary S. Varner , Larry L. Ruckman

The operation of solid-state qubits often relies on single-shot readout using a nanoelectronic charge sensor, and the detection of events in a noisy sensor signal is crucial for high fidelity readout of such qubits. The most common…

Mesoscale and Nanoscale Physics · Physics 2015-06-09 J. R. Prance , B. J. Van Bael , C. B. Simmons , D. E. Savage , M. G. Lagally , Mark Friesen , S. N. Coppersmith , M. A. Eriksson

We investigate the performance of superconducting nanowire photon detectors fabricated from ultra-thin Nb. A direct comparison is made between these detectors and similar nanowire detectors fabricated from NbN. We find that Nb detectors are…

Liquid scintillators are a common choice for neutrino physics experiments, but their capabilities to perform background rejection by scintillation pulse shape discrimination is generally limited in large detectors. This paper describes a…

Liquid scintillator detectors are widely used in neutrino experiments due to their low energy threshold and high energy resolution. Despite the tiny abundance of $^{14}$C in LS, the photons induced by the $\beta$ decay of the $^{14}$C…

Instrumentation and Detectors · Physics 2026-03-31 Junle Li , Zhaoxiang Wu , Guanda Gong , Zhaohan Li , Wuming Luo , Jiahui Wei , Wenxing Fang , Hehe Fan

We extend the study of the performance of a prototype two-phase liquid xenon WIMP dark matter detector to recoil energies below 20 keV. We demonstrate a new method for obtaining the best estimate of the energies of events using a calibrated…

Astrophysics · Physics 2008-11-26 T. Shutt , C. E. Dahl , J. Kwong , A. Bolozdynya , P. Brusov