Related papers: A room-temperature alternating current susceptomet…
In atomic magnetometers, the vector AC-Stark shift associated with circularly polarized light generates spatially varying effective magnetic fields which limit the magnetometer response and serve as sources of noise. We describe a scheme…
Recent developments of the AC-calorimetric technique adapted for the needs of high pressure experiments are discussed. A semi-quantitative measurement of the specific heat with a Bridgman-type of pressure cell as well as a diamond anvil…
We propose a new method to measure the system noise temperature, $T_{\rm sys}$, using a 2-bit analog-to-digital converter (ADC). The statistics of the digitized signal in a four-level quantization brings us information about the bias…
Sensors based on spin qubits in 2D crystals offer the prospect of nanoscale sensing volumes, where the close proximity of the sensor and source could provide access to otherwise inaccessible signals. For AC magnetometry, the sensitivity and…
In this article, operation of optical magnetometers detecting static (DC) and oscillating (AC) magnetic fields is studied and comparison of the devices is performed. To facilitate the comparison, the analysis is carried out in the same…
The design and performance of a sensitive and reliable cross-correlation spectrum analyzer for studying low frequency transport noise is described in detail. The design makes use of common PC-based data acquisition hardware and…
We have thoroughly investigated the entire magnetic states of under doped ferromagnetic insulating manganite Nd0.8Sr0.2MnO3 through temperature dependent linear and non linear complex ac magnetic susceptibility measurements. This…
This paper deals with an analytical modeling of heat transfers simulating a new radiation calorimeter operating in a temperature range from -50 {\deg}C to 150 {\deg}C. The aim of this modeling is the evaluation of the feasibility and…
We report on a single-channel rubidium radio-frequency atomic magnetometer operating in un-shielded environments and near room temperature with a measured sensitivity of 130 fT/\sqrt{Hz}. We demonstrate consistent, narrow-bandwidth…
Low-noise cryogenic microwave amplifiers are widely used in applications such as radio astronomy and quantum computing. On-wafer noise characterization of cryogenic low-noise transistors is desirable because it facilitates more rapid…
We introduce a calorimetric approach to probe persistent currents in normal metal rings. The heat capacity of a large ensemble of silver rings is measured by nanocalorimetry under a varying magnetic field at different temperatures (60 mK,…
Measurements of thermal activation are made in a superconducting, niobium Persistent-Current (PC) qubit structure, which has two stable classical states of equal and opposite circulating current. The magnetization signal is read out by…
Membrane based nanocalorimeters have been developed for ac calorimetry experiments. It has allowed highly sensitive measurements of heat capacity from solid state physics to complex systems like polymers and proteins. In this article we…
The operation of polarimetric based single beam three axis atomic magnetometer is studied. The magnetometer operates in presence of small bias magnetic field. Its salient features are compared with the analysis of Bloch equation. The…
We describe a set up for measurements of low frequency (1 mHz < f < 20 Hz) conductance fluctuations in a solid conductor. The set-up uses a five probe a.c. measurement technique and extensive digital signal processing to reach a noise floor…
A Seebeck coefficient measurement apparatus has been designed and developed, which is very effective for accurate characterization of different type of samples in a wide temperature range (80 - 650K) simultaneously covering low as well as…
Remote sensing of magnetic nanoparticles has exciting applications for magnetic nanoparticle hyperthermia and molecular detection. We introduce, simulate, and experimentally demonstrate an innovation---a sensing coil that is geometrically…
We measure the temperature, magnetic-field, and current dependence for the switching of nanomagnets by a spin-polarized current. Depending on current bias, switching can occur between either two static magnetic states or a static state and…
Cold atom magnetometers exploit a dense ensemble of quanta with long coherence times to realise leading sensitivity on the micrometer scale. Configured as a Ramsey interferometer, a cold atom sensor can approach atom shot-noise limited…
The DC and AC magnetic susceptibilities of Na0.85CoO2 single crystals were measured for the different crystal orientations of H//(ab)- and H//(c)-axis. The DC-magnetic susceptibility for H//(c)-direction exhibited the antiferromagnetic…