English
Related papers

Related papers: Electromagnetic Shower Properties in a Lead-Scinti…

200 papers

The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the hadronic calorimeter, one option is a highly granular sampling…

Instrumentation and Detectors · Physics 2012-08-08 C. Adloff , J. Blaha , J. -J. Blaising , C. Drancourt , A. Espargilière , R. Gaglione , N. Geffroy , Y. Karyotakis , J. Prast , G. Vouters , K. Francis , J. Repond , J. Smith , L. Xia , E. Baldolemar , J. Li , S. T. Park , M. Sosebee , A. P. White , J. Yu , Y. Mikami , N. K. Watson T. Goto , G. Mavromanolakis , M. A. Thomson , D. R. Ward W. Yan , M. Benyamna , C. Cârloganu , F. Fehr , P. Gay , S. Manen , L. Royer , G. C. Blazey , A. Dyshkant , J. G. R. Lima , V. Zutshi , J. -Y. Hostachy , L. Morin , U. Cornett , D. David , R. Fabbri , G. Falley , K. Gadow , E. Garutti , P. Göttlicher , C. Günter , S. Karstensen , F. Krivan , A. -I. Lucaci-Timoce , S. Lu , B. Lutz , I. Marchesini , N. Meyer , S. Morozov , V. Morgunov , M. Reinecke , F. Sefkow , P. Smirnov , M. Terwort , A. Vargas-Trevino , N. Wattimena , O. Wendt , N. Feege , J. Haller , S. Richter , J. Samson P. Eckert , A. Kaplan , H. -Ch. Schultz-Coulon , W. Shen , R. Stamen , A. Tadday , B. Bilki , E. Norbeck , Y. Onel , G. W. Wilson , K. Kawagoe , S. Uozumi , J. A. Ballin , P. D. Dauncey , A. -M. Magnan , H. S. Yilmaz , O. Zorba , V. Bartsch , M. Postranecky , M. Warren , M. Wing , F. Salvatore , E. Calvo Alamillo , M. -C. Fouz , J. Puerta-Pelayo , V. Balagura , B. Bobchenko , M. Chadeeva , M. Danilov , A. Epifantsev , O. Markin , R. Mizuk , E. Novikov , V. Rusinov , E. Tarkovsky , Y. Soloviev , V. Kozlov , P. Buzhan , B. Dolgoshein , A. Ilyin , V. Kantserov , V. Kaplin , A. Karakash , E. Popova , S. Smirnov , A. Frey , C. Kiesling , K. Seidel , F. Simon , C. Soldner , L. Weuste , J. Bonis , B. Bouquet , S. Callier , P. Cornebise , Ph. Doublet , F. Dulucq , M. Faucci Giannelli , J. Fleury , G. Guilhem , H. Li , G. Martin-Chassard , F. Richard , Ch. de la Taille , R. Pöschl , L. Raux , N. Seguin-Moreau , F. Wicek , M. Anduze , V. Boudry , J-C. Brient , D. Jeans , P. Mora de Freitas , G. Musat , M. Reinhard , M. Ruan , H. Videau , B. Bulanek , J. Zacek , J. Cvach , P. Gallus , M. Havranek , M. Janata , J. Kvasnicka , D. Lednicky , M. Marcisovsky , I. Polak , J. Popule , L. Tomasek , M. Tomasek , P. Ruzicka , P. Sicho , J. Smolik , V. Vrba , J. Zalesak , B. Belhorma , H. Ghazlane , K. Kotera , M. Nishiyama , T. Takeshita , S. Tozuka , T. Buanes , G. Eigen

We developed a novel apparatus based on a lead glass calorimeter that can measure the flux of high-energy electrons or photons. Our detector uses the electromagnetic shower leakage from the beam dump, where the particles are disposed of at…

We present results of the performance of the second prototype of the CASTOR quartz-tungsten sampling calorimeter, to be installed in the very forward region of the CMS experiment at the LHC. The energy linearity and resolution, as well as…

Simulations of particle showers in calorimeters are computationally time-consuming, as they have to reproduce both energy depositions and their considerable fluctuations. A new approach to ultra-fast simulations are generative models where…

Instrumentation and Detectors · Physics 2020-02-05 Martin Erdmann , Jonas Glombitza , Thorben Quast

The CDF experiment is successfully collecting data from ppbar collisions at the Tevatron in Run II. As the data samples are getting larger, systematic uncertainties due to the measurement of the jet energy scale assessed using the…

Instrumentation and Detectors · Physics 2019-08-14 Pedro A. Movilla Fernandez

A small prototype of a finely granulated digital hadron calorimeter with Resistive Plate Chambers as active elements was exposed to positive pions of 1 >. 16 GeV energy from the Fermilab test beam. The event selection separates events with…

Instrumentation and Detectors · Physics 2015-05-14 Burak Bilki , John Butler , Georgios Mavromanolakis , Ed May , Edwin Norbeck , Jose Repond , David Underwood , Lei Xia , Qingmin Zhang

The operation and performance of the Compact Muon Solenoid (CMS) electromagnetic calorimeter (ECAL) are presented, based on data collected in pp collisions at $\sqrt{s}$ = 13 TeV at the CERN LHC, in the years from 2015 to 2018 (LHC Run 2),…

Instrumentation and Detectors · Physics 2024-09-06 CMS Collaboration

The intrinsic time structure of hadronic showers has been studied to evaluate its influence on the timing capability and on the required integration time of highly granular hadronic calorimeters in future collider experiments. The…

Instrumentation and Detectors · Physics 2019-08-13 Frank Simon

The electromagnetic calorimeters of the various magnetic spectrometers in Hall C at Jefferson Lab are presented. For the existing HMS and SOS spectrometers design considerations, relevant construction information, and comparisons of…

We propose to build the Electromagnetic calorimeter for the HADES di-lepton spectrometer. It will enable to measure the data on neutral meson production from nucleus-nucleus collisions, which are essential for interpretation of dilepton…

We present a design for a high-granularity calorimeter insert for future experiments at the Electron-Ion Collider (EIC). The sampling-calorimeter design uses scintillator tiles read out with silicon photomultipliers. It maximizes coverage…

A prototype of a Si-W EM calorimeter was built with Monolithic Active Pixel Sensors as the active elements. With a pixelsize of 30 $\mu$m it allows digital calorimetry, i.e. the particles' energy is determined by counting pixels, not by…

Instrumentation and Detectors · Physics 2018-02-14 A. P. de Haas , G. Nooren , T. Peitzmann , M. Reicher , E. Rocco , D. Roehrich , K. Ullaland , A. van den Brink , M. van Leeuwen , H. Wang , S. Yang , C. Zhang

The CALICE collaboration is developing a granular electromagnetic calorimeter using (5-10) mm x 45 mm x 3 mm scintillator strips for a future linear collider experiment. Each scintillator strip is read out by using a Pixelated Photon…

Instrumentation and Detectors · Physics 2012-02-01 Katsushige Kotera

Based on a new approach to the detection of radio transients associated with extensive air showers induced by ultra high energy cosmic rays, the experimental apparatus CODALEMA is in operation, measuring about 1 event per day corresponding…

The CSC (cryogenic scintillating calorimeter) technology devoted to rare event searches is reaching the sensitivity level required for the hunt of dark matter-electron scatterings. Dark matter-electron interactions in scintillating targets…

High Energy Physics - Phenomenology · Physics 2025-07-18 V. Zema , P. Figueroa , G. Angloher , M. R. Bharadwaj , T. Frank , M. N. Hughes , M. Kellermann , F. Pröbst , K. Schäffner , K. Shera , M. Stahlberg

A novel calorimeter sensor for electron, photon and hadron energy measurement based on Secondary Emission(SE) to measure ionization is described, using sheet-dynodes directly as the active detection medium; the shower particles in an SE…

NuTeV is a neutrino-nucleon deep inelastic scattering experiment at Fermilab. The NuTeV detector is a traditional heavy target neutrino detector which consists of an iron/liquid scintillator sampling calorimeter followed by a muon…

High Energy Physics - Experiment · Physics 2019-08-18 S. Avvakumov , T. Adams , A. Alton , L. de Barbaro , P. de Barbaro , D. Berlin , R. H. Bernstein , A. Bodek , T. Bolton , J. Brau , D. Buchholz , H. Budd , L. Bugel

In this study, we propose a novel fully active total absorption calorimeter with enhanced read out capabilities through fine splitting. The proposed calorimeter employs a sandwich structure composed of scintillator glasses and lead glasses,…

Instrumentation and Detectors · Physics 2023-07-04 T. Takeshita , R. Terada

The SND is a non-magnetic detector at the VEPP-2000 $e^{+} e^{-}$ collider (BINP, Novosibirsk) designed for hadronic cross-section measurements in the center-of-mass energy range up to $2$ GeV. The important part of the detector is a…