Related papers: Monitor backscatter factors for the Varian 21EX an…
Modulated electron radiotherapy (MERT) and combined, modulated photon/electron radiotherapy (MPERT) have received increased research attention, having shown capacity for reduced low dose exposure to healthy tissue and comparable, if not…
Monte Carlo (MC) simulation of linacs depends on the accurate geometrical description of the head. The geometry of the Varian TrueBeam (TB) linac is not available to researchers. Instead, the company distributes phase-space files (PSFs) of…
Monte Carlo (MC) simulation is considered as the most accurate method for radiation dose calculations. Accuracy of a source model for a linear accelerator is critical for the overall dose calculation accuracy. In this paper, we presented an…
Purpose: To investigate the validity of two Monte Carlo simulation absolute dosimetry approaches in the case of a small field dedicated `D'-shaped collimator used for the retinoblastoma treatment with external photon beam radiotherapy.…
Flattening filter free (FFF) beams due to their non-uniformity, are sub-optimal for larger field sizes. The purpose of this study was to investigate the incident electron beam distributions that would produce flat FFF beams without the use…
A novel approach of accurately reconstructing storage ring's linear optics from turn-by-turn (TbT) data containing measurement error is introduced. This approach adopts a Bayesian inference based on the Markov Chain Monte-Carlo (MCMC)…
Microbeam radiation therapy (MRT) utilizes coplanar synchrotron radiation beamlets and is a proposed treatment approach for several tumour diagnoses that currently have poor clinical treatment outcomes, such as gliosarcomas. Prescription…
Standard 6 megavolt (MV) radiotherapy is limited by source size and secondary electron range to minimum radiological penumbra widths of ~2-3 mm. This study investigates sharper beams via upright radiotherapy with lower energies and extended…
In this article we consider Bayesian estimation of static parameters for a class of partially observed McKean-Vlasov diffusion processes with discrete-time observations over a fixed time interval. This problem features several obstacles to…
Purpose: To evaluate the latent variance (LV) of TrueBeam photon phase-space files (PSF) for open 10x10$cm^2$ and small fields. Methods: BEAMnrc/DOSXYZnrc was used to transport particles from Varian phase-space files (PSFA) through the…
This study develops and validates a patient-specific Monte Carlo (MC) dosimetry framework for propagation-based phase-contrast breast CT (BCT) at the Imaging and Medical Beamline (IMBL), ANSTO Australian Synchrotron, for accurate mean…
PURPOSE: Permanent breast seed implant (PBSI) using 103Pd is emerging as an effective adjuvant radiation technique for early-stage breast cancer. However, clinical dose evaluations follow the water-based TG-43 approach with its considerable…
Purpose: Retinoblastoma (RB) is the most common eye tumor in childhood and can be treated external radiotherapy. The purpose of this work is to evaluate the adequacy of Monte Carlo simulations and the accuracy of a commercial treatment…
Purpose: To develop a Monte Carlo (MC) therapeutic dose calculation toolkit of a recently released ring gantry linac in Geant4 (Version 10.7) for secondary dose validation of radiotherapy plan. Methods: For the Halcyon (Varian Medical…
Purpose: A Monte Carlo (MC) beam model and its implementation in a clinical treatment planning system (TPS, Varian Eclipse) are presented for a modified ultra-high dose-rate electron FLASH radiotherapy (eFLASH-RT) LINAC. Methods: The gantry…
Bayesian methods are commonly applied to solve image analysis problems such as noise-reduction, feature enhancement and object detection. A primary limitation of these approaches is the computational complexity due to the interdependence of…
We present a fast and scalable estimator for the binned multi-frequency angular bispectrum (MABS) and the 3D bispectrum (BS) of the redshifted 21 cm signal from radio interferometric observations. The estimator operates on gridded…
This paper presents a new Bayesian model and algorithm used for depth and intensity profiling using full waveforms from the time-correlated single photon counting (TCSPC) measurement in the limit of very low photon counts. The model…
In superconducting linear accelerators (linacs), accurately monitoring beam dynamics is essential for minimizing beam losses and ensuring stable operations. However, destructive diagnostics must be avoided in superconducting sections to…
Computed Tomography (CT) imaging, while essential for diagnostics, exposes patients to ionizing radiation. To accurately quantify radiation dosage, this study introduces MIDSX, a specialized open-source Monte Carlo (MC) photon transport…